Effect of Tracheal Cuff Shape on Intracuff Pressure Change During Robot-Assisted Laparoscopic Surgery: The Tapered-Shaped Cuff Tube Versus the Cylindrical-Shaped Cuff Tube

被引:6
作者
Seo, Hyungseok [1 ]
Bang, Ji-yeon [2 ]
Oh, Jimi [2 ]
Choi, Woo-Jong [2 ]
Song, Jun-Gol [2 ]
Hwang, Gyu-Sam [2 ]
机构
[1] Seoul Natl Univ, Coll Med, Seoul Natl Univ Hosp, Dept Anesthesia & Pain Med, Seoul, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Anesthesiol & Pain Med, Seoul 138736, South Korea
来源
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES | 2015年 / 25卷 / 09期
关键词
POSTOPERATIVE SORE THROAT; ENDOTRACHEAL-TUBE; PROSTATECTOMY; ANESTHESIA; VOLUME;
D O I
10.1089/lap.2015.0152
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Although the cuff of tracheal tubes can reduce airflow leakage and prevent aspiration, excessive intracuff pressure can cause tracheal mucosal injury. Robot-assisted laparoscopic surgery (RALS) can increase intracuff pressure by the Trendelenburg position and pneumoperitoneum. The aim of our current study was to investigate the effect of tracheal cuff shape on the intracuff pressure increase by comparing two different-shaped cuffs during RALS. Materials and Methods: Ninety-eight patients undergoing RALS were allocated randomly into two groups (tapered-shaped cuff [TSC] and cylindrical-shaped cuff [CSC] groups). The intracuff pressure was measured at nine specific time points: after intubation, immediately after surgical preparation (Trendelenburg position with CO2 insufflation), at 5, 10, 15, 30, 60, and 90 minutes after surgical preparation, and at the end of surgery. Postintubation airway symptoms were measured by assessing sore throat, hoarseness, and excessive cough 1 hour after postanesthesia care unit admission. Results: Intracuff pressure significantly increased during surgery in both groups. The trend of intracuff pressure change decreased in the TSC group compared with the CSC group, although no statistically significant changes were found (P=.450). Also, there were no statistically significant differences in the postintubation airway symptom between the two groups. Conclusions: The TSC tube has a tendency to decrease intracuff pressure change compared with the CSC tube during RALS. However, neither of them was beneficial in preventing intraoperative intracuff pressure increase during RALS.
引用
收藏
页码:724 / 729
页数:6
相关论文
共 17 条
[1]   Comparison of volume-controlled and pressure-controlled ventilation in steep Trendelenburg position for robot-assisted laparoscopic radical prostatectomy [J].
Choi, Eun Mi ;
Na, Sungwon ;
Choi, Seung Ho ;
An, Jiwon ;
Rha, Koon Ho ;
Oh, Young Jun .
JOURNAL OF CLINICAL ANESTHESIA, 2011, 23 (03) :183-188
[2]   Intracuff Pressure and Tracheal Morbidity - Influence of Filling Cuff with Saline during Nitrous Oxide Anesthesia [J].
Combes, X ;
Schauvliege, F ;
Peyrouset, O ;
Motamed, C ;
Kirov, K ;
Dhonneur, G ;
Duvaldestin, P .
ANESTHESIOLOGY, 2001, 95 (05) :1120-1124
[3]   Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study [J].
Dave, M. H. ;
Frotzler, A. ;
Spielmann, N. ;
Madjdpour, C. ;
Weiss, M. .
BRITISH JOURNAL OF ANAESTHESIA, 2010, 105 (04) :538-543
[4]   Nitrous oxide diffusion into tracheal tube cuffs: comparison of five different tracheal tube cuffs [J].
Dullenkopf, A ;
Gerber, AC ;
Weiss, M .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2004, 48 (09) :1180-1184
[5]   The effect of endotracheal tube cuff pressure change during gynecological laparoscopic surgery on postoperative sore throat: a control study [J].
Geng, Guiqi ;
Hu, Jingyi ;
Huang, Shaoqiang .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (01) :141-144
[6]   Influence of airway pressure on minimum occlusive endotracheal tube cuff pressure [J].
Guyton, DC ;
Barlow, MR ;
Besselievre, TR .
CRITICAL CARE MEDICINE, 1997, 25 (01) :91-94
[7]   Correlations Between Controlled Endotracheal Tube Cuff Pressure and Postprocedural Complications: A Multicenter Study [J].
Liu, Jianhui ;
Zhang, Xiaoqing ;
Gong, Wei ;
Li, Shitong ;
Wang, Fen ;
Fu, Shukun ;
Zhang, Mazhong ;
Hang, Yannan .
ANESTHESIA AND ANALGESIA, 2010, 111 (05) :1133-1137
[8]   Comparison of air-sealing characteristics of tapered- vs. cylindrical-shaped high-volume, low-pressure tube cuffs [J].
Madjdpour, C. ;
Mauch, J. ;
Dave, M. H. ;
Spielmann, N. ;
Weiss, M. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2012, 56 (02) :230-235
[9]   Sore throat and hoarseness after total intravenous anaesthesia [J].
Maruyama, K ;
Sakai, H ;
Miyazawa, H ;
Toda, N ;
Iinuma, Y ;
Mochizuki, N ;
Hara, K ;
Otagiri, T .
BRITISH JOURNAL OF ANAESTHESIA, 2004, 92 (04) :541-543
[10]   Postoperative sore throat: cause, prevention and treatment [J].
McHardy, FE ;
Chung, F .
ANAESTHESIA, 1999, 54 (05) :444-453