Unattended versus Attended Blood Pressure Measurement: Relationship with Retinal Microcirculation

被引:7
|
作者
Paini, Anna [1 ]
Agabiti Rosei, Claudia [2 ,3 ]
De Ciuceis, Carolina [1 ]
Aggiusti, Carlo [1 ]
Bertacchini, Fabio [2 ,3 ]
Cacciatore, Marco [2 ]
Capellini, Sara [2 ,3 ]
Gatta, Roberto [4 ]
Malerba, Paolo [2 ,3 ]
Stassaldi, Deborah [2 ,3 ]
Rizzoni, Damiano [5 ,6 ]
Salvetti, Massimo [1 ]
Muiesan, Maria Lorenza [2 ,3 ]
机构
[1] Univ Brescia & Emergency Med ASST Spedali Civili B, Dept Clin & Expt Sci, I-25121 Brescia, Italy
[2] Univ Brescia, Dept Clin & Expt Sci, Med ASST Spedali Civili Brescia 2a, I-25121 Brescia, Italy
[3] ASST Spedali Civili diBrescia, Med 2a, I-25121 Brescia, Italy
[4] Univ Brescia, Dept Clin & Expt Sci, I-25123 Brescia, Italy
[5] Univ Brescia & Med Montichiari ASST Spedali Civili, Dept Clin & Expt Sci, I-25121 Brescia, Italy
[6] Med Montichiari ASST Spedali Civili Brescia, I-25121 Brescia, Italy
关键词
unattended blood pressure; AOBP; blood pressure measurement; retinal arterioles; media; lumen ratio; wall-to-lumen ratio; adaptive optics; TO-LUMEN RATIO; AUTOMATED OFFICE; MICROVASCULAR STRUCTURE; TASK-FORCE; HYPERTENSION; ARTERIOLES; PREVENTION; GUIDELINES; MANAGEMENT; DIAGNOSIS;
D O I
10.3390/jcm11236966
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Though the relationship between both "attended" and "unattended" BP and several forms of target organ damage have been evaluated, data on retinal arteriolar alterations are lacking. The aim of our study was to evaluate the relationship between "attended" or "unattended" BP values and retinal arteriolar changes in consecutive individuals undergoing a clinical evaluation and assessment of retinal fundus at an ESH Excellence Centre. An oscillometric device programmed to perform 3 BP measurements, at 1 min intervals and after 5 min of rest was used on all individuals to measure BP with the patient alone in the room ("unattended") or in the presence of the physician ("attended") in the same day in a random order. The retinal arteriole's wall thickness (WT) was measured automatically by a localization algorithm as the difference between external (ED) and internal diameter (ID) by adaptive optics (RTX-1, Imagine Eyes, Orsay, Francia). Media-to-lumen ratio (WLR) of the retinal arterioles and cross-sectional area (WCSA) of the vascular wall were calculated. Results: One-hundred-forty-two patients were examined (mean age 57 +/- 12 yrs, 48% female, mean BMI 26 +/- 4). Among them, 60% had hypertension (84% treated) and 11% had type 2 diabetes mellitus. Unattended systolic BP (SBP) was lower as compared to attended SBP (129 +/- 14.8. vs. 122.1 +/- 13.6 mmHg, p < 0.0001). WLR was similarly correlated with unattended and attended SBP (r = 0.281, p < 0.0001 and r = 0.382, p < 0.0001) and with unattended and attended diastolic BP (r = 0.34, p < 0.001 and r = 0.29, p < 0.0001). The differences between correlations were not statistically significant (Steiger's Z test). Conclusion: The measurement of "unattended" or "attended" BP provides different values, and unattended BP is lower as compared to attended BP. In this study a similar correlation was observed between attended and unattended BP values and structural changes of retinal arterioles.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Attended Versus Unattended Automated Office Blood Pressure: A Systematic Review and Meta-analysis
    Andreadis, Emmanuel A.
    Thomopoulos, Costas
    Geladari, Charalampia V.
    Papademetriou, Vasilios
    HIGH BLOOD PRESSURE & CARDIOVASCULAR PREVENTION, 2019, 26 (04) : 293 - 303
  • [22] Attended vs unattended systolic blood pressure measurement: A randomized comparison in patients with cardiovascular disease
    Keeley, Ellen C.
    Villanueva, Matthew
    Chen, Yiqing E.
    Gong, Yan
    Handberg, Eileen M.
    Smith, Steven M.
    Pepine, Carl J.
    Cooper-DeHoff, Rhonda M.
    JOURNAL OF CLINICAL HYPERTENSION, 2020, 22 (11): : 1987 - 1992
  • [23] Comparison of nurse attended and unattended automated office blood pressure with conventional measurement techniques in clinical practice
    Elvira Fanelli
    Silvia Di Monaco
    Marco Pappaccogli
    Elisabetta Eula
    Chiara Fasano
    Chiara Bertello
    Franco Veglio
    Franco Rabbia
    Journal of Human Hypertension, 2022, 36 : 833 - 838
  • [24] Unattended versus two attended, ambulatory and central blood pressure measurements in hypertensive patients with and without diabetes
    Polonia, Jorge
    Baptista, Cristina
    Silva, Jose
    Barbosa, Loide
    BLOOD PRESSURE, 2019, 28 (02) : 99 - 106
  • [25] Differences in the diagnosis of high blood pressure using unattended and attended automated office blood pressure
    Paiva, Annelise M. G.
    Mota-Gomes, Marco A.
    Feitosa, Audes D. M.
    Azevedo, Thomas C. P.
    Amorim, Natalia W.
    Mion, Decio, Jr.
    Sposito, Andrei C.
    Nadruz, Wilson, Jr.
    JOURNAL OF HUMAN HYPERTENSION, 2022, 36 (04) : 370 - 372
  • [26] Comparison of nurse attended and unattended automated office blood pressure with conventional measurement techniques in clinical practice
    Fanelli, Elvira
    Di Monaco, Silvia
    Pappaccogli, Marco
    Eula, Elisabetta
    Fasano, Chiara
    Bertello, Chiara
    Veglio, Franco
    Rabbia, Franco
    JOURNAL OF HUMAN HYPERTENSION, 2022, 36 (09) : 833 - 838
  • [27] Differences in the diagnosis of high blood pressure using unattended and attended automated office blood pressure
    Annelise M. G. Paiva
    Marco A. Mota-Gomes
    Audes D. M. Feitosa
    Thomás C. P. Azevedo
    Natalia W. Amorim
    Decio Mion
    Andrei C. Sposito
    Wilson Nadruz
    Journal of Human Hypertension, 2022, 36 : 370 - 372
  • [28] UNATTENDED AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT VERSUS CLASSIC OFFICE AUTOMATED BLOOD PRESSURE MEASUREMENT IN A HYPERTENSION OUTPATIENT CLINIC
    Legrady, Peter
    Fejes, Imola
    Czombos, Andras
    Abraham, Gyorgy
    JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E99 - E99
  • [29] DIAGNOSTIC ACCURACY OF ATTENDED AND UNATTENDED BLOOD PRESSURE MEASUREMENTS IN PATIENTS WITH ARTERIAL HYPERTENSION
    Mancusi, Costantino
    Maloberti, Alessandro
    Fucile, Ilaria
    Manzi, Maria Virigina
    Pengo, Martino
    Bertacchini, Fabio
    Monticone, Silvia
    Pucci, Giacomo
    JOURNAL OF HYPERTENSION, 2024, 42
  • [30] COMPARISON OF ATTENDED WITH UNATTENDED BLOOD PRESSURE MEASUREMENTS PERFORMED BY TWO DIFFERENT DEVICES
    Filipovsky, Jan
    Seidlerova, Jitka Mlikova
    Gelzinsky, Julius
    Mares, Stepan
    Mayer, Otto
    JOURNAL OF HYPERTENSION, 2023, 41 : E7 - E8