Convection Condensation Heat Transfer of Steam-Air Mixture With Heat Pipe Heat Exchanger

被引:13
作者
Ma, Xuehu [1 ]
Lan, Zhong [1 ]
Xu, Wei [1 ]
Zhang, Chongfeng [1 ]
Fang, Zheng [1 ]
Bai, Tao [1 ]
机构
[1] Dalian Univ Technol, Inst Chem Engn, Dalian 116024, Peoples R China
关键词
DROPWISE CONDENSATION; VERTICAL TUBE; RECOVERY; GAS; THERMOSIPHON; DESIGN;
D O I
10.1080/01457632.2013.837649
中图分类号
O414.1 [热力学];
学科分类号
摘要
A heat pipe heat exchanger (HPHE) was used to investigate the heat transfer performance of steam-air mixture condensation, analogous to the dew condensation of flue gas, when the steam volume fraction ranged from 0 to 20%, and the inlet temperature of steam-air mixture varied from 70 to 120 degrees C. Self-assembled monolayers (SAMs) treatment with n-octadecyl mercaptan was adopted to modify the condensation surface of the heat pipe. The comparisons were conducted to examine the influence of SAMs on condensation heat transfer of steam-air mixture vapor. The results indicate that the convection condensation heat transfer coefficient increases with the increase of steam volume fraction and Re number of the steam-air mixture. As the inlet temperature increases, the heat transfer coefficient decreases accordingly. The heat transfer performance can be improved by the SAMs surface, with a heat transfer enhancement ratio up to 1.6 at a condition of 20% of the steam volume fraction and 1500 Re number.
引用
收藏
页码:600 / 609
页数:10
相关论文
共 26 条
[1]   Heat pipe heat exchanger for heat recovery in air conditioning [J].
Abd El-Baky, Mostafa A. ;
Mohamed, Mousa M. .
APPLIED THERMAL ENGINEERING, 2007, 27 (04) :795-801
[2]   Theoretical and experimental investigation of heat pipe solar collector [J].
Azad, E. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2008, 32 (08) :1666-1672
[3]  
Bevington P.R., 1969, DATA REDUCTION ERROR, P56
[4]  
Che D. F., 2002, CONDENSING BOILERS S
[5]   Design of cooler condensers for mixtures of vapors with noncondensing gases [J].
Colburn, AP ;
Hougen, OA .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1934, 26 :1178-1182
[6]   Air heat exchangers with long heat pipes: Experiments and predictions [J].
Hagens, H. ;
Ganzevles, F. L. A. ;
van der Geld, C. W. M. ;
Grooten, M. H. M. .
APPLIED THERMAL ENGINEERING, 2007, 27 (14-15) :2426-2434
[7]  
Hsu S. T., 1963, ENG HEAT TRANSFER
[8]   Effects of water vapor condensation on the convection heat transfer of wet flue gas in a vertical tube [J].
Jia, L ;
Peng, XF ;
Yan, Y ;
Sun, JD ;
Li, XP .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (22) :4257-4265
[9]   Experimental investigation of wraparound loop heat pipe heat exchanger used in energy efficient air handling units [J].
Jouhara, Hussam ;
Meskimmon, Richard .
ENERGY, 2010, 35 (12) :4592-4599
[10]   DESIGN, CONSTRUCTION AND TESTING OF A THERMOSIPHON HEAT-EXCHANGER FOR MEDIUM-TEMPERATURE HEAT-RECOVERY IN BAKERIES [J].
LUKITOBUDI, AR ;
AKBARZADEH, A ;
JOHNSON, PW ;
HENDY, P .
HEAT RECOVERY SYSTEMS & CHP, 1995, 15 (05) :481-491