Rapid Detection of Mobilized Colistin Resistance using a Nucleic Acid Based Lab-on-a-Chip Diagnostic System

被引:24
作者
Rodriguez-Manzano, Jesus [1 ,2 ]
Moser, Nicolas [2 ]
Malpartida-Cardenas, Kenny [2 ]
Moniri, Ahmad [2 ]
Fisarova, Lenka [2 ]
Pennisi, Ivana [2 ]
Boonyasiri, Adhiratha [1 ]
Jauneikaite, Elita [1 ,3 ]
Abdolrasouli, Alireza [1 ]
Otter, Jonathan A. [1 ,4 ]
Bolt, Frances [1 ]
Davies, Frances [1 ]
Didelot, Xavier [5 ,6 ]
Holmes, Alison [1 ]
Georgiou, Pantelis [2 ]
机构
[1] Imperial Coll London, Fac Med, Dept Infect Dis, NIHR Hlth Protect Res Unit Healthcare Associated, London, England
[2] Imperial Coll London, Dept Elect & Elect Engn, Fac Engn, Ctr Bioinspired Technol, London, England
[3] Imperial Coll London, Sch Publ Hlth, Dept Infect Dis Epidemiol, London, England
[4] St Marys Hosp, Imperial Coll Healthcare NHS Trust, London, England
[5] Univ Warwick, Sch Life Sci, Coventry, W Midlands, England
[6] Univ Warwick, Dept Stat, Coventry, W Midlands, England
基金
英国工程与自然科学研究理事会;
关键词
ISOTHERMAL AMPLIFICATION LAMP; ALGORITHM;
D O I
10.1038/s41598-020-64612-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The increasing prevalence of antimicrobial resistance is a serious threat to global public health. One of the most concerning trends is the rapid spread of Carbapenemase-Producing Organisms (CPO), where colistin has become the last-resort antibiotic treatment. The emergence of colistin resistance, including the spread of mobilized colistin resistance (mcr) genes, raises the possibility of untreatable bacterial infections and motivates the development of improved diagnostics for the detection of colistin-resistant organisms. This work demonstrates a rapid response for detecting the most recently reported mcr gene, mcr-9, using a portable and affordable lab-on-a-chip (LoC) platform, offering a promising alternative to conventional laboratory-based instruments such as real-time PCR (qPCR). The platform combines semiconductor technology, for non-optical real-time DNA sensing, with a smartphone application for data acquisition, visualization and cloud connectivity. This technology is enabled by using loop-mediated isothermal amplification (LAMP) as the chemistry for targeted DNA detection, by virtue of its high sensitivity, specificity, yield, and manageable temperature requirements. Here, we have developed the first LAMP assay for mcr-9 - showing high sensitivity (down to 100 genomic copies/reaction) and high specificity (no cross-reactivity with other mcr variants). This assay is demonstrated through supporting a hospital investigation where we analyzed nucleic acids extracted from 128 carbapenemase-producing bacteria isolated from clinical and screening samples and found that 41 carried mcr-9 (validated using whole genome sequencing). Average positive detection times were 6.58 +/- 0.42min when performing the experiments on a conventional qPCR instrument (n=41). For validating the translation of the LAMP assay onto a LoC platform, a subset of the samples were tested (n=20), showing average detection times of 6.83 +/- 0.92min for positive isolates (n=14). All experiments detected mcr-9 in under 10min, and both platforms showed no statistically significant difference (p-value>0.05). When sample preparation and throughput capabilities are integrated within this LoC platform, the adoption of this technology for the rapid detection and surveillance of antimicrobial resistance genes will decrease the turnaround time for DNA detection and resistotyping, improving diagnostic capabilities, patient outcomes, and the management of infectious diseases.
引用
收藏
页数:9
相关论文
共 42 条
[1]  
Andrews S., 2015, A Quality Control Tool for High Throughput Sequence Data. Babraham Bioinformatics
[2]  
[Anonymous], 2016, RECOMMENDATIONS MIC
[3]   Live Demonstration: A Mobile Diagnostic System for Rapid Detection and Tracking of Infectious Diseases [J].
Au, Anselm ;
Moser, Nicolas ;
Rodriguez-Manzano, Jesus ;
Georgiou, Pantelis .
2018 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2018,
[4]   SPAdes: A New Genome Assembly Algorithm and Its Applications to Single-Cell Sequencing [J].
Bankevich, Anton ;
Nurk, Sergey ;
Antipov, Dmitry ;
Gurevich, Alexey A. ;
Dvorkin, Mikhail ;
Kulikov, Alexander S. ;
Lesin, Valery M. ;
Nikolenko, Sergey I. ;
Son Pham ;
Prjibelski, Andrey D. ;
Pyshkin, Alexey V. ;
Sirotkin, Alexander V. ;
Vyahhi, Nikolay ;
Tesler, Glenn ;
Alekseyev, Max A. ;
Pevzner, Pavel A. .
JOURNAL OF COMPUTATIONAL BIOLOGY, 2012, 19 (05) :455-477
[5]  
Banoo S, 2010, NAT REV MICROBIOL, pS17, DOI [10.1038/nrmicro1523, 10.1038/nrmico1523]
[6]   Identification of Novel Mobilized Colistin Resistance Gene mcr-9 in a Multidrug-Resistant, Colistin-Susceptible Salmonella enterica Serotype Typhimurium Isolate [J].
Carroll, Laura M. ;
Gaballa, Ahmed ;
Guldimann, Claudia ;
Sullivan, Genevieve ;
Henderson, Lory O. ;
Wiedmann, Martin .
MBIO, 2019, 10 (03)
[7]  
Craw P, 2012, LAB CHIP, V12, P2469, DOI [10.1039/c2lc40100b, 10.1039/c21c40100b]
[8]   Electrochemical DNA sensors [J].
Drummond, TG ;
Hill, MG ;
Barton, JK .
NATURE BIOTECHNOLOGY, 2003, 21 (10) :1192-1199
[9]   SlipChip [J].
Du, Wenbin ;
Li, Liang ;
Nichols, Kevin P. ;
Ismagilov, Rustem F. .
LAB ON A CHIP, 2009, 9 (16) :2286-2292
[10]   On-chip electrical detection of parallel loop-mediated isothermal amplification with DG-BioFETs for the detection of foodborne bacterial pathogens [J].
Duarte-Guevara, Carlos ;
Swaminathan, Vikhram V. ;
Reddy, Bobby, Jr. ;
Huang, Jui-Cheng ;
Liu, Yi-Shao ;
Bashir, Rashid .
RSC ADVANCES, 2016, 6 (106) :103872-103887