Use of imaging for procedural guidance during transcatheter aortic valve replacement

被引:15
作者
Hahn, Rebecca T. [1 ]
机构
[1] Columbia Univ, Med Ctr, New York Presbyterian Hosp, New York, NY 10032 USA
关键词
computed tomography; transcatheter aortic valve replacement; transesophageal echocardiography; 3-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY; MULTIDETECTOR COMPUTED-TOMOGRAPHY; VALVULAR HEART-DISEASE; CARDIOVASCULAR MAGNETIC-RESONANCE; MEDTRONIC COREVALVE PROSTHESIS; VENTRICULAR EJECTION FRACTION; LANDING ZONE CALCIFICATION; EXPERT CONSENSUS DOCUMENT; HIGH-RISK PATIENTS; LOW-GRADIENT;
D O I
10.1097/HCO.0b013e3283632b5e
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose of reviewTranscatheter aortic valve replacement (TAVR) has recently emerged as an alternative to surgical aortic valve replacement for patients with severe, symptomatic aortic stenosis who are at a high risk' or deemed inoperable. Multiple imaging modalities are integral to procedural success and recent studies may help establish the role of each modality.Recent findingsProcedural guidance includes preimplantation device selection, intraprocedural guidance of valve positioning and post-implantation assessment of procedural success. Numerous studies have suggested that three-dimensional (3D) assessment of the aortic annulus and adjacent structures by multislice computed tomography (MSCT) or cardiac MRI can improve annular sizing and reduce complications. Subsequent studies suggest that 3D transesophageal echocardiography (TEE) can also accurately measure the annular aortic annulus. New imaging techniques help with coaxial fluoroscopic positioning. Finally, the use of intraprocedural TEE allows imaging of complications.SummaryMultimodality imaging is indispensable for procedural guidance during TAVR. MSCT is a fundamental part of preprocedural planning, including the assessment of peripheral vasculature, the aortic root and the annulus and optimal fluoroscopic positioning. Echocardiography, particularly two-dimensional (2D) and 3D TEE, is an integral part of preprocedural, intraprocedural and immediate postprocedural assessment. MRI remains at this time an adjunctive imaging modality for procedural guidance, but may have an essential role in postprocedural valve assessment.
引用
收藏
页码:512 / 517
页数:6
相关论文
共 82 条
[1]   Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry [J].
Abdel-Wahab, Mohamed ;
Zahn, Ralf ;
Horack, Martin ;
Gerckens, Ulrich ;
Schuler, Gerhard ;
Sievert, Horst ;
Eggebrecht, Holger ;
Senges, Jochen ;
Richardt, Gert .
HEART, 2011, 97 (11) :899-906
[2]   SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR) [J].
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Schoenhagen, Paul ;
Min, James K. ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) :366-380
[3]   Low-Flow, Low-Gradient Severe Aortic Stenosis Despite Normal Ejection Fraction Is Associated With Severe Left Ventricular Dysfunction as Assessed by Speckle-Tracking Echocardiography A Multicenter Study [J].
Adda, Jerome ;
Mielot, Christopher ;
Giorgi, Roch ;
Cransac, Frederic ;
Zirphile, Xavier ;
Donal, Erwan ;
Sportouch-Dukhan, Catherine ;
Reant, Patricia ;
Laffitte, Stephane ;
Cade, Stephane ;
Le Dolley, Yvan ;
Thuny, Franck ;
Touboul, Nathalie ;
Lavoute, Cecile ;
Avierinos, Jean-Francois ;
Lancellotti, Patrizio ;
Habib, Gilbert .
CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (01) :27-35
[4]   Aortic root morphology in patients undergoing percutaneous aortic valve replacement: Evidence of aortic root remodeling [J].
Akhtar, Mateen ;
Tuzcu, E. Murat ;
Kapadia, Samir R. ;
Svensson, Lars G. ;
Greenberg, Roy K. ;
Roselli, Eric E. ;
Halliburton, Sandra ;
Kurra, Vikram ;
Schoenhagen, Paul ;
Sola, Srikanth .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (04) :950-956
[5]   Unexpected Complications of Transapical Aortic Valve Implantation [J].
Al-Attar, Nawwar ;
Ghodbane, Walid ;
Himbert, Dominique ;
Rau, Cederic ;
Raffoul, Richard ;
Messika-Zeitoun, David ;
Brochet, Eric ;
Vahanian, Alec ;
Nataf, Patrick .
ANNALS OF THORACIC SURGERY, 2009, 88 (01) :90-94
[6]   Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation [J].
Altiok, Ertunc ;
Koos, Ralf ;
Schroeder, Joerg ;
Brehmer, Kathrin ;
Hamada, Sandra ;
Becker, Michael ;
Mahnken, Andreas H. ;
Almalla, Mohammad ;
Dohmen, Guido ;
Autschbach, Ruediger ;
Marx, Nikolaus ;
Hoffmann, Rainer .
HEART, 2011, 97 (19) :1578-1584
[7]  
[Anonymous], EUR HEART J
[8]   Incidence, Predictors, and Outcomes of Aortic Regurgitation After Transcatheter Aortic Valve Replacement Meta-Analysis and Systematic Review of Literature [J].
Athappan, Ganesh ;
Patvardhan, Eshan ;
Tuzcu, E. Murat ;
Svensson, Lars Georg ;
Lemos, Pedro A. ;
Fraccaro, Chiara ;
Tarantini, Giuseppe ;
Sinning, Jan-Malte ;
Nickenig, Georg ;
Capodanno, Davide ;
Tamburino, Corrado ;
Latib, Azeem ;
Colombo, Antonio ;
Kapadia, Samir R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (15) :1585-1595
[9]   Usefulness of TEE as the Primary Imaging Technique to Guide Transcatheter Transapical Aortic Valve Implantation [J].
Bagur, Rodrigo ;
Rodes-Cabau, Josep ;
Doyle, Daniel ;
De Larochelliere, Robert ;
Villeneuve, Jacques ;
Lemieux, Jerome ;
Bergeron, Sebastien ;
Cote, Melanie ;
Bertrand, Olivier F. ;
Pibarot, Philippe ;
Dumont, Eric .
JACC-CARDIOVASCULAR IMAGING, 2011, 4 (02) :115-124
[10]   Two-Dimensional Strain for the Assessment of Left Ventricular Function in Low Flow-Low Gradient Aortic Stenosis, Relationship to Hemodynamics, and Outcome A Substudy of the Multicenter TOPAS Study [J].
Bartko, Philipp Emanuel ;
Heinze, Georg ;
Graf, Senta ;
Clavel, Marie-Annick ;
Khorsand, Aliasghar ;
Bergler-Klein, Jutta ;
Burwash, Ian Gordon ;
Dumesnil, Jean Gaston ;
Senechal, Mario ;
Baumgartner, Helmut ;
Rosenhek, Raphael ;
Pibarot, Philippe ;
Mundigler, Gerald .
CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (02) :268-276