A new cesium ion selective graphite rod electrode based on Cs-molybdophosphate

被引:21
作者
Arida, HAM [1 ]
Aglan, RF [1 ]
El-Reefy, SA [1 ]
机构
[1] Atom Energy Author, Hot Lab Ctr, Cairo 13759, Egypt
关键词
cesium selective electrode; Cs-12-molybdophosphate; coated graphite rod; potentiometric determination;
D O I
10.1081/AL-120027771
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new poly(vinyl chloride) (PVC) electrode for Cs+ ion based on Cs-12-molybdophosphate (Cs-12-MPO) as a membrane carrier is prepared and characterized. The electrode exhibits a linear response with slope of 46.5 +/- 1 mV/decade within the concentration range of 1.0 x 10(-5)-1.0 X 10(-1) mol L-1 Cs+ ion. The limit of detection was 3.0 x 10(-6) mol L-1. The proposed electrode shows a good selectivity for Cs+ ion over a wide variety of other metal ions and could be used in the pH range of 4.0-6.0. It has a relatively fast response time less than (30 s) and can be used for at least three weeks without any considerable divergence in potentials. The proposed electrode is applied as a sensor for the determination of Cs+ ion concentration in some samples. The results show a good correlation with the data obtained by atomic absorption spectrometric method. The average recovery obtained is 92 +/- 0.5% with a standard deviation of 1.2%.
引用
收藏
页码:21 / 33
页数:13
相关论文
共 37 条
[1]   A COMPARATIVE-STUDY OF THE EFFECT OF ORTHO-NITROPHENYL OCTYL ETHER AND ORTHO-NITROPHENYL PENTYL ETHER AS PLASTICIZERS ON THE RESPONSE AND SELECTIVITY OF CARRIER-BASED LIQUID MEMBRANE ION-SELECTIVE ELECTRODES [J].
ATTIYAT, AS ;
CHRISTIAN, GD ;
HALLMAN, JL ;
BARTSCH, RA .
TALANTA, 1988, 35 (10) :789-794
[2]   DETERMINATION OF PARTS-PER-MILLION CESIUM IN SIMULATED NUCLEAR WASTE WITH CESIUM-SELECTIVE ELECTRODE [J].
BAUMANN, EW .
ANALYTICAL CHEMISTRY, 1976, 48 (03) :548-552
[3]  
BIBOW K, 1990, CLIN CHEM, V36, P1902
[4]  
BOGUSLAWSKA K, 1985, CHEM ANAL-WARSAW, V30, P281
[5]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[6]   LASER ATOMIC-IONIZATION DETERMINATION OF CESIUM IN FLAMES [J].
CHAPLYGIN, VI ;
ZOROV, NB ;
KUZYAKOV, YY .
TALANTA, 1983, 30 (07) :505-508
[7]  
CHAPLYGIN VI, 1983, ZH ANAL KHIM, V38, P802
[8]   DETERMINATION OF TRACE-ELEMENTS IN BIOLOGICAL-MATERIALS BY INSTRUMENTAL EPITHERMAL NEUTRON-ACTIVATION ANALYSIS [J].
CHISELA, F ;
BRATTER, P .
ANALYTICA CHIMICA ACTA, 1986, 188 :85-94
[9]   CESIUM-SENSITIVE ELECTRODE [J].
COETZEE, CJ ;
BASSON, AJ .
ANALYTICA CHIMICA ACTA, 1971, 57 (02) :478-&
[10]   CESIUM-SENSITIVE LIQUID MEMBRANE ELECTRODE [J].
COETZEE, CJ ;
BASSON, AJ .
ANALYTICA CHIMICA ACTA, 1976, 83 (MAY) :361-365