Multidimensional dosimetry of 106Ru eye plaques using EBT3 films and its impact on treatment planning

被引:19
作者
Heilemann, G. [1 ,2 ]
Nesvacil, N. [1 ]
Blaickner, M. [3 ]
Kostiukhina, N. [1 ]
Georg, D. [1 ,2 ]
机构
[1] Med Univ Viennal, Dept Radiat Oncol, Ctr Comprehens Canc, AKH Vienna, A-1090 Vienna, Austria
[2] Christian Doppler Lab Med Radiat Res Radiat Oncol, A-1090 Vienna, Austria
[3] Austrian Inst Technol GmbH, Hlth & Environm Dept Biomed Syst, A-1220 Vienna, Austria
基金
奥地利科学基金会;
关键词
brachytherapy; eye plaque; radiochromic film; dosimetry; quality assurance; TARGETED RADIONUCLIDE THERAPY; 15 YEARS EXPERIENCE; OPHTHALMIC APPLICATORS; STEREOTACTIC RADIOTHERAPY; DOSE DISTRIBUTIONS; RADIATION-THERAPY; UVEAL MELANOMA; TUMOR-CONTROL; BRACHYTHERAPY; I-125;
D O I
10.1118/1.4929564
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to establish a method to perform multidimensional radiochromic film measurements of Ru-106 plaques and to benchmark the resulting dose distributions against Monte Carlo simulations (MC), microdiamond, and diode measurements. Methods: Absolute dose rates and relative dose distributions in multiple planes were determined for three different plaque models (CCB, CCA, and COB), and three different plaques per model, using EBT3 films in an in-house developed polystyrene phantom and the MCNP6 MC code. Dose difference maps were generated to analyze interplaque variations for a specific type, and for comparing measurements against MC simulations. Furthermore, dose distributions were validated against values specified by the manufacturer (BEBIG) and microdiamond and diode measurements in a water scanning phantom. Radial profiles were assessed and used to estimate dosimetric margins for a given combination of representative tumor geometry and plaque size. Results: Absolute dose rates at a reference depth of 2 mm on the central axis of the plaque show an agreement better than 5% (10%) when comparing film measurements (MCNP6) to the manufacturer's data. The reproducibility of depth-dose profile measurements was <7% (2 SD) for all investigated detectors and plaque types. Dose difference maps revealed minor interplaque deviations for a specific plaque type due to inhomogeneities of the active layer. The evaluation of dosimetric margins showed that for a majority of the investigated cases, the tumor was not completely covered by the 100% isodose prescribed to the tumor apex if the difference between geometrical plaque size and tumor base <= 4 mm. Conclusions: EBT3 film dosimetry in an in-house developed phantom was successfully used to characterize the dosimetric properties of different Ru-106 plaque models. The film measurements were validated against MC calculations and other experimental methods and showed a good agreement with data from BEBIG well within published tolerances. The dosimetric information as well as interplaque comparison can be used for comprehensive quality assurance and for considerations in the treatment planning of ophthalmic brachytherapy. (C) 2015 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页码:5798 / 5808
页数:11
相关论文
共 51 条
  • [1] 42ICRU, 1989, REPORT 44
  • [2] Evaluation of material heterogeneity dosimetric effects using radiochromic film for COMS eye plaques loaded with 125I seeds (model I25.S16)
    Acar, Hilal
    Chiu-Tsao, Sou-Tung
    Ozbay, Ismail
    Kemikler, Gonul
    Tuncer, Samuray
    [J]. MEDICAL PHYSICS, 2013, 40 (01)
  • [3] A comprehensive study of the Gafchromic EBT2 radiochromic film. A comparison with EBT
    Andres, C.
    del Castillo, A.
    Tortosa, R.
    Alonso, D.
    Barquero, R.
    [J]. MEDICAL PHYSICS, 2010, 37 (12) : 6271 - 6278
  • [4] [Anonymous], NCS REP
  • [5] [Anonymous], 1987, SPECIFIC ABSORBED FR
  • [6] [Anonymous], GEC ESTRO HDB BRACHY
  • [7] Conformal episcleral plaque therapy
    Astrahan, MA
    Luxton, G
    Pu, Q
    Petrovich, Z
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 505 - 519
  • [8] BINDER W, 1990, RADIAT PROT DOSIM, V34, P275
  • [9] 15 years experience with helium ion radiotherapy for uveal melanoma
    Castro, JR
    Char, DH
    Petti, PL
    Daftari, IK
    Quivey, JM
    Singh, RP
    Blakely, EA
    Phillips, TL
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (05): : 989 - 996
  • [10] Chan M F, 2001, J Appl Clin Med Phys, V2, P85, DOI 10.1120/1.1351776