A compact system for two-dimensional readout of Gas Electron Multiplier detectors

被引:14
|
作者
Mindur, B. [1 ]
Dabrowski, W. [1 ]
Fiutowski, T. [1 ]
Wiacek, P. [1 ]
Zielinska, A. [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, Krakow, Poland
来源
JOURNAL OF INSTRUMENTATION | 2013年 / 8卷
关键词
Software architectures (event data models; frameworks and databases); Front-end electronics for detector readout; Data acquisition concepts; TRACKING;
D O I
10.1088/1748-0221/8/01/T01005
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
There is a growing interest in the use of Gas Electron Multiplier (GEM) and other micro-pattern gas detectors (MPGD) for two-dimensional (2-D) position sensitive measurements of photons or charged particles. A Gas Electron Multiplier Readout Chip (GEMROC) is an Application Specific Integrated Circuit (ASIC) dedicated for 2-D strip readout of GEM detectors. The ASICs deliver the amplitudes and time coordinates of the signals recorded on two sets of orthogonal strips. Timing information is used for finding coincidences of signals on two spatial coordinates while amplitude information is used to find the center of gravity for the cluster of signals belonging to the same detection event. In this paper we present a Field Programmable Gate Array (FPGA) based compact readout system dedicated for these ASICs. The readout system consists of two synchronized FPGA-ADC boards connected to four front-end boards, each one equipped with two GEMROCs. Both FPGAs are connected to a DAQ PC using separate Gigabit Ethernet links. The DAQ PC is equipped with a dedicated C++ based software, which is responsible for configuration of the FPGAs and ASICs settings, storing all the incoming data as well as for on-line/off-line data processing and visualization. The performance of the system is illustrated by test bench measurements.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Solitons in a two-dimensional electron gas
    Nerses, A.
    Kunhardt, E.E.
    Physics Letters, Section A: General, Atomic and Solid State Physics, 1999, 251 (02): : 137 - 142
  • [22] Properties of the two-dimensional electron gas
    Orozco, S
    Méndez-Moreno, RM
    Moreno, M
    JOURNAL OF MOLECULAR STRUCTURE-THEOCHEM, 1999, 493 : 211 - 217
  • [23] TWO-DIMENSIONAL SIMULATION OF INTEGRATED DETECTORS AND ELECTRON DEVICES
    BERGER, M
    STEIN, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 253 (03): : 382 - 385
  • [24] Development and applications of gas electron multiplier detectors
    Sauli, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 195 - 198
  • [25] A mixed-signal ASIC for the readout of Gas Electron Multiplier detectors Design review and characterization results
    Cossio, Fabio
    2017 13TH CONFERENCE ON PH.D. RESEARCH IN MICROELECTRONICS AND ELECTRONICS (PRIME), 2017, : 33 - 36
  • [26] Microstrip gas chamber with true two-dimensional and pixel readout
    Angelini, F.
    Bellazzini, R.
    Bosisio, L.
    Brez, A.
    Massai, M.M.
    Perret, A.
    Spandre, G.
    Torquati, M.R.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992, A323 (1-2) : 229 - 235
  • [27] Electron spin resonance on a two-dimensional electron gas
    Nestle, N
    Denninger, G
    Vidal, M
    Weinzierl, C
    Brunner, K
    Eberl, K
    vonKlitzing, K
    PHYSICAL REVIEW B, 1997, 56 (08) : R4359 - R4362
  • [28] Electron parametric resonance in a two-dimensional electron gas
    Calvo, M
    PHYSICAL REVIEW B, 1997, 55 (16): : 10571 - 10577
  • [29] Electron parametric resonance in a two-dimensional electron gas
    Calvo, M.
    Physical Review B: Condensed Matter, 55 (16):
  • [30] Imaging electron density in a two-dimensional electron gas
    LeRoy, BJ
    Topinka, MA
    Westervelt, RM
    Maranowski, KD
    Gossard, AC
    APPLIED PHYSICS LETTERS, 2002, 80 (23) : 4431 - 4433