Hapten immobilization for antibody sensing using a dynamic modification protocol

被引:11
作者
Fry, DR [1 ]
Bobbitt, DR [1 ]
机构
[1] Univ Arkansas, Dept Chem & Biochem, Fayetteville, AR 72701 USA
基金
美国国家科学基金会;
关键词
optical fibers; haptens; 2,4 dinitrophenyl; sensors;
D O I
10.1016/S0039-9140(01)00529-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Optical fiber (OF) sensors are often limited by the immobilization technique used to associate a specific sensing ligand with the OF surface. This is particularly true when the ligand is biologically active as, for example, in the case of immobilized haptens or antibodies. The dynamic modification protocol is a regenerable and experimentally simple way to immobilize a variety of sensing molecules on an OF surface. Furthermore, the protocol is immune to hydrolysis and not limited by diffusion through a membrane or sol-gel. In this publication the approach is extended by immobilizing the hydrophobic hapten (octadecyl 6-(2,4 dinitrophenyl)aminohexanoic acid) as a means to prepare an OF sensor for antibodies specific for 2,4 dinitrophenyl (DNP). The LOD for anti-DNP is 0.5 nanomolar and the K-apparent is 1.0 +/- 0.2 x 10(6). Nonspecific antibody adsorption is problematic in this sensing approach and was found to limit the quantitative capabilities of the sensor. However, time discrimination can be used to allow the nonspecific antibody to desorb prior to measurement thus minimizing the influence of nonspecific binding on sensor performance. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1195 / 1203
页数:9
相关论文
共 19 条
  • [1] Quantifying serum antiplague antibody with a fiber-optic biosensor
    Anderson, GP
    King, KD
    Cao, LK
    Jacoby, M
    Ligler, FS
    Ezzell, J
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 1998, 5 (05) : 609 - 612
  • [2] BENJAMINI E, 1991, IMMUNOLOGY SHORT COU, P459
  • [3] DYNAMICALLY COATED COLUMNS AND CONDUCTIVITY DETECTION FOR TRACE DETERMINATION OF ORGANIC-ANIONS BY ION CHROMATOGRAPHY
    CASSIDY, RM
    ELCHUK, S
    [J]. JOURNAL OF CHROMATOGRAPHY, 1983, 262 (JUN): : 311 - 315
  • [4] DYNAMICALLY COATED COLUMNS FOR THE SEPARATION OF METAL-IONS AND ANIONS BY ION CHROMATOGRAPHY
    CASSIDY, RM
    ELCHUK, S
    [J]. ANALYTICAL CHEMISTRY, 1982, 54 (09) : 1558 - 1563
  • [5] Development of an electrochemical immunosensor for direct detection of interferon-γ at the attomolar level
    Dijksma, M
    Kamp, B
    Hoogvliet, JC
    van Bennekom, WP
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (05) : 901 - 907
  • [6] JANATA J, 1989, PRINCIPLES CHEM SENS, P317
  • [7] A fiber-optic evanescent wave DNA biosensor based on novel molecular beacons
    Liu, XJ
    Tan, WH
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (22) : 5054 - 5059
  • [8] AVIDIN BIOTIN COUPLING AS A GENERAL-METHOD FOR PREPARING ENZYME-BASED FIBER-OPTIC SENSORS
    LUO, SF
    WALT, DR
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (10) : 1069 - 1072
  • [9] Malmsten M., 1995, COLLOID SURFACE B, V3, P297
  • [10] Fiber optic-based biosensor for ricin
    Narang, U
    Anderson, GP
    Ligler, FS
    Burans, J
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (9-10) : 937 - 945