Systematic studies on adsorption of trace elements Pt, Pd, Au, Se, Te, As, Hg, Sb on thiol cotton fiber

被引:75
作者
Yu, MQ [1 ]
Sun, DW [1 ]
Tian, W [1 ]
Wang, GP [1 ]
Shen, WB [1 ]
Xu, N [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Geog, Ctr Environm Res, Changchun 130021, Peoples R China
关键词
thiol cotton fiber; trace elements; adsorption; desorption; multi-enrichment; selective separation;
D O I
10.1016/S0003-2670(02)00004-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The modified thiol cotton fiber (TCF) can quantitatively adsorb Pt(II), Pd(II), Au(III), Se(IV), Te(TV), As(III), Hg(II) and Sb(III) strongly in addition to its adsorption of Bi(III), Sn(II), Ag(I), Cu(II), In(III), Pb(II), Cd(II), Zn(II), Co(II), Ni(II), and TI(I). In a HCl solution, the adsorption order for the eight elements is Pt(II) approximate to Pd(II) > Au(III) approximate to Se(IV) > Te(IV) > As(III) > Hg(II) > Sb(111). The adsorption capability of TCF for these eight ions depends on the affinity of -SH for the ions and complexing reactions in solution. The extent of adsorption of TCF for the ions depends on the varieties of elements, the oxidation states and species of the elements, and the acidity and the components of the solution. In general, TCF only adsorbs ions in their lower oxidation states. The saturation adsorption of TCF for the eight elements is 10-70 mg g(-1). For a column with 0.1 g of TCF, except for As(III) and Se(IV) the quantitative adsorption flow rate for the other six elements is 10-30 ml min(-1). The ions adsorbed on TCF can be separated and quantitatively desorbed with 2-3 ml of a desorption reagent under suitable conditions. The experiments showed that most matrix elements, complexing reagents and organic compounds do not interfere with the quantitative adsorption of the trace elements on TCF The recoveries of the standards at the mug l(-1) level of the eight elements added to four types of natural water samples are all >85%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:147 / 155
页数:9
相关论文
共 11 条
[2]   ONLINE PRECONCENTRATION OF SILVER ON A SULFHYDRYL COTTON MICROCOLUMN AND DETERMINATION BY FLOW-INJECTION ATOMIC-ABSORPTION SPECTROMETRY [J].
GOMEZ, MMG ;
GARCIA, MMH ;
CORVILLO, MAP .
ANALYST, 1995, 120 (07) :1911-1915
[3]  
HUANG R, 1997, GOLD, V18, P46
[4]   DETERMINATION OF METHYLMERCURY IN NATURAL-WATERS AT THE SUB-NANOGRAMS PER LITER LEVEL BY CAPILLARY GAS-CHROMATOGRAPHY AFTER ADSORBENT PRECONCENTRATION [J].
LEE, YH ;
MOWRER, J .
ANALYTICA CHIMICA ACTA, 1989, 221 (02) :259-268
[5]  
MOREIRA JC, 1990, MIKROCHIM ACTA, V3, P107
[6]   DETERMINATION OF GOLD IN SLUDGE AND SOIL BY SEQUENTIAL ICP-AES AFTER PRECONCENTRATION AND SEPARATION WITH THIOL-COTTON FIBER [J].
XU, LQ ;
SCHRAMEL, P .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (1-2) :179-182
[7]   DETERMINATION OF TRACE ARSENIC, ANTIMONY, SELENIUM AND TELLURIUM IN VARIOUS OXIDATION-STATES IN WATER BY HYDRIDE GENERATION AND ATOMIC-ABSORPTION SPECTROPHOTOMETRY AFTER ENRICHMENT AND SEPARATION WITH THIOL COTTON [J].
YU, MQ ;
LIU, GQ ;
JIN, Q .
TALANTA, 1983, 30 (04) :265-270
[8]   Systematic studies on adsorption of 11 trace heavy metals on thiol cotton fiber [J].
Yu, MQ ;
Tian, W ;
Sun, DW ;
Shen, WB ;
Wang, GP ;
Xu, N .
ANALYTICA CHIMICA ACTA, 2001, 428 (02) :209-218
[9]  
YU MQ, 1986, ENV SCI, V7, P71
[10]  
YU MQ, 1981, ACTA SCI CIRCUMSTANT, V1, P180