PET/MR for therapy response evaluation in malignant lymphoma: initial experience

被引:34
作者
Platzek, Ivan [1 ]
Beuthien-Baumann, Bettina [2 ]
Langner, Jens [3 ]
Popp, Manuel [2 ]
Schramm, Georg [3 ]
Ordemann, Rainer [4 ]
Laniado, Michael [1 ]
Kotzerke, Joerg [2 ]
van den Hoff, Joerg [3 ]
机构
[1] Dresden Univ Hosp, Dept Radiol, D-01307 Dresden, Germany
[2] Dresden Univ Hosp, Dept Nucl Med, Dresden, Germany
[3] Helmholtz Zentrum Dresden Rossendorf, Inst Radiopharm, Dresden, Germany
[4] Dresden Univ Hosp, Med Clin & Polyclin 1, Dresden, Germany
关键词
PET; MRI; Lymphoma; MRI; DISEASE;
D O I
10.1007/s10334-012-0342-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the feasibility of positron emission tomography/magnetic resonance imaging (PET/MR) with (18)fluoro-2-deoxyglucose (FDG) for therapy response evaluation of malignant lymphoma. Nine patients with malignant lymphoma who underwent FDG-PET/MR before and after chemotherapy were included in this retrospective study. Average time between the two scans was 70 days. The scans were evaluated independently by two nuclear medicine physicians. The Ann Arbor classification was used to describe lymphoma stage. Furthermore, the readers also rated PET image quality using a five point scale. Weighted kappa (kappa) was used to calculate interrater agreement. The initial scan showed foci of increased FDG uptake in all patients, with Ann Arbor stage varying between I and IV. In the follow-up examination, all but one patient showed complete response to chemotherapy. PET image quality was rated as very good or excellent for all scans. Interrater agreement was excellent regarding Ann Arbor stage (kappa = 0.97) and good regarding image quality (kappa = 0.41). PET/MR shows promising initial results for therapy response evaluation in lymphoma patients.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 12 条
[1]  
Beyer T, 2000, J NUCL MED, V41, P1369
[2]  
CARBONE PP, 1971, CANCER RES, V31, P1860
[3]  
Czernin J, 2007, J NUCL MED, V48, p78S
[4]   First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses [J].
Drzezga, Alexander ;
Souvatzoglou, Michael ;
Eiber, Matthias ;
Beer, Ambros J. ;
Fuerst, Sebastian ;
Martinez-Moeller, Axel ;
Nekolla, Stephan G. ;
Ziegler, Sibylle ;
Ganter, Carl ;
Rummeny, Ernst J. ;
Schwaiger, Markus .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (06) :845-855
[5]   Whole-Body Diffusion-Weighted Imaging: The Added Value to Whole-Body MRI at Initial Diagnosis of Lymphoma [J].
Gu, Jing ;
Chan, Tao ;
Zhang, Jingbo ;
Leung, Anskar Y. H. ;
Kwong, Yok-Lam ;
Khong, Pek-Lan .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) :W384-W391
[6]   Use of positron emission tomography for response assessment of lymphoma: Consensus of the Imaging Subcommittee of International Harmonization Project in lymphoma [J].
Juweid, Malik E. ;
Stroobants, Sigrid ;
Hoekstra, Otto S. ;
Mottaghy, Felix M. ;
Dietlein, Markus ;
Guermazi, Ali ;
Wiseman, Gregory A. ;
Kostakoglu, Lale ;
Scheidhauer, Klemens ;
Buck, Andreas ;
Naumann, Ralph ;
Spaepen, Karoline ;
Hicks, Rodney J. ;
Weber, Wolfgang A. ;
Reske, Sven N. ;
Schwaiger, Markus ;
Schwartz, Lawrence H. ;
Zijlstra, Josee M. ;
Siegel, Barry A. ;
Cheson, Bruce D. .
JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (05) :571-578
[7]   Imaging in staging of malignant lymphoma: asystematic review [J].
Kwee, Thomas C. ;
Kwee, Robert M. ;
Nievelstein, Rutger A. J. .
BLOOD, 2008, 111 (02) :504-516
[8]   Radiation exposure and mortality risk from CT and PET imaging of patients with malignant lymphoma [J].
Nievelstein, R. A. J. ;
van Ufford, H. M. E. Quarles ;
Kwee, T. C. ;
Bierings, M. B. ;
Ludwig, I. ;
Beek, F. J. A. ;
de Klerk, J. M. H. ;
Mali, W. P. Th. M. ;
de Bruin, P. W. ;
Geleijns, J. .
EUROPEAN RADIOLOGY, 2012, 22 (09) :1946-1954
[9]   Hodgkin disease: Diagnostic value of FDG PET/CT after first-line therapy - Is biopsy of FDG-avid lesions still needed? [J].
Schaefer, Niklaus G. ;
Taverna, Christian ;
Strobel, Klaus ;
Wastl, Cathrin ;
Kurrer, Michael ;
Hany, Thomas F. .
RADIOLOGY, 2007, 244 (01) :257-262
[10]   Newly Diagnosed Lymphoma: Initial Results With Whole-Body T1-Weighted, STIR, and Diffusion-Weighted MRI Compared With 18F-FDG PET/CT [J].
van Ufford, Henriette M. E. Quarles ;
Kwee, Thomas C. ;
Beek, Frederik J. ;
van Leeuwen, Maarten S. ;
Takahara, Taro ;
Fijnheer, Rob ;
Nievelstein, Rutger A. J. ;
de Klerk, John M. H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (03) :662-669