Elimination of micropollutants by activated carbon produced from fibers taken from wastewater screenings using hydrothermal carbonization

被引:41
作者
Benstoem, F. [1 ]
Becker, G. [2 ]
Firk, J. [1 ]
Kaless, M. [1 ]
Wuest, D. [2 ]
Pinnekamp, J. [1 ]
Kruse, A. [2 ]
机构
[1] Rhein Westfal TH Aachen, Inst Environm Engn, Mies van der Rohe Str 1, D-52074 Aachen, Germany
[2] Univ Hohenheim, Inst Agr Engn, Chair Convers Technol & Life Cycle Assessment Ren, Garbenstr 9, D-70599 Stuttgart, Germany
关键词
HTC; Activated carbon; Waste water treatment; Sieving; Emerging substance; Chemical activation; ORGANIC MICROPOLLUTANTS; BIOMASS; REMOVAL; ADSORBENTS; ADSORPTION; CONVERSION; CELLULOSE; POROSITY;
D O I
10.1016/j.jenvman.2018.01.065
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Activated Carbon (AC) can be used to reduce organic micropollutants (OMPs) in wastewater treatment plants (WWTPs). While producing ACs conventionally still damages the environment, this can be reduced by using renewable raw material from waste streams and producing AC locally. In this study, fibers (toilet paper) were separated out of wastewater by screening WWTP influents in full scale and then used as a no-cost, carbon-rich and heavy metal-poor raw material to produce ACs. Pretreatment was hydrothermal carbonization (HTC). Thereafter, they were activated using KOH to generate activated carbons (HTC-ACs). Their functional groups were characterized using FT-IR, and the alteration of their chemical composition was traced by elementary analysis. Adsorption tests were performed with nitrogen (BET surface) and methylene blue as standard tests. The adsorption capacity was tested with WWTP effluent and the removal of UVA(254) as a surrogate for OMP removal was measured. After HTC and activation 13-16% of the fibers dry mass was obtained as HTC-ACs. Higher dehydration and formation of aromatic structures on the HTC-ACs were detected with FT-IR as HTC and activation temperature increased. BET surface and methylene blue adsorption of some HTC-ACs was higher than the Reference AC. Nevertheless, their ability to reduce OMPs is still lower than the Reference AC due to the different nature of their functional groups and their microporous structure that is not fully accessible for OMPs in real wastewater. Further research has to be carried out to adjust the production process so as to obtain mesoporous HTC-ACs tailored to reduce OMP concentrations and to close the carbon loop within WWTPs. (C) 2018 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.
引用
收藏
页码:278 / 286
页数:9
相关论文
共 42 条
[1]  
[Anonymous], 2009, 11885 EN ISO
[2]  
[Anonymous], 2012, Pharmaceuticals in drinking-water
[3]  
[Anonymous], 2001, 12879 DIN EN
[4]  
[Anonymous], J COLLOID INTERF SCI, DOI DOI 10.1016/0095-8522(66)90006-7
[5]   Predicting trace organic compound breakthrough in granular activated carbon using fluorescence and UV absorbance as surrogates [J].
Anumol, Tarun ;
Sgroi, Massimiliano ;
Park, Minkyu ;
Roccaro, Paolo ;
Snyder, Shane A. .
WATER RESEARCH, 2015, 76 :76-87
[6]  
BAFU, 2012, MIKR KOMM ABW UMW WI
[7]   Characteristic numbers of granular activated carbon for the elimination of micropollutants from effluents of municipal wastewater treatment plants [J].
Benstoem, F. ;
Pinnekamp, J. .
WATER SCIENCE AND TECHNOLOGY, 2017, 76 (02) :279-285
[8]   Performance of granular activated carbon to remove micropollutants from municipal wastewater-A meta-analysis of pilot- and large-scale studies [J].
Benstoem, Frank ;
Nahrstedt, Andreas ;
Boehler, Marc ;
Knopp, Gregor ;
Montag, David ;
Siegrist, Hansruedi ;
Pinnekamp, Johannes .
CHEMOSPHERE, 2017, 185 :105-118
[9]  
Berardi R, 2006, TOILET PAPER INNOVAT
[10]   Evaluation of hydrothermal carbonization as a preliminary step for the production of functional materials from biogas digestate [J].
Correa, Catalina Rodriguez ;
Bernardo, Maria ;
Ribeiro, Rui P. P. L. ;
Esteves, Isabel A. A. C. ;
Kruse, Andrea .
JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 2017, 124 :461-474