Mass Transfer Studies in Pulsed Sieve Plate Extraction Column for the Removal of Tributyl Phosphate from Aqueous Nitric Acid

被引:21
|
作者
Lade, Vikesh G. [1 ]
Pakhare, Achyut D. [1 ]
Rathod, Virendra K. [1 ]
机构
[1] Inst Chem Technol, Dept Chem Engn, Matunga Mumbai 400010, India
关键词
DISPERSED PHASE HOLDUP; DROP SIZE DISTRIBUTION; N-BUTYL PHOSPHATE; TRANSFER COEFFICIENTS; REACTIVE EXTRACTION; SIMULATION TOOL; SOLVENT; PERFORMANCE; EFFICIENCY; DESIGN;
D O I
10.1021/ie401384j
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Removal of a saturated amount of tributyl phosphate (TBP) from a nuclear reprocessing aqueous waste stream is very important as far as economy of process as well as waste disposal is concerned. The present research work describes the detailed mass transfer studies for the removal of TBP from aqueous stream in a geometrically optimized pulsed sieve plate extraction column (PSPEC). The original industrial system, viz., 0.3 M nitric acid-TBP-normal paraffinic hydrocarbon (NPH), was used for the mass transfer studies. The effect of operating parameters such as continuous to dispersed phase velocity ratio and pulsed velocity on the volumetric mass transfer coefficient was investigated. The effect of operating parameters on the variation in axial concentration and holdup profile is also studied to evaluate the dynamic operation of the column for the attainment of steady state. The experimental results indicate that pulse velocity has a strong effect on the volumetric mass transfer coefficient, while the effect of the continuous phase flow rate is greater than the effect of the dispersed phase flow rate.
引用
收藏
页码:4812 / 4820
页数:9
相关论文
共 50 条
  • [1] Mass transfer in pulsed sieve plate extraction column
    Qian, Yu
    Fei, Weiyang
    Wang, Jiading
    Journal of Chemical Industry and Engineering (China) (English Edition), 1988, 39 (05): : 522 - 529
  • [2] Mass transfer characteristics in extraction column with trapezoidal pulsed sieve plate
    Zhang, Weibo
    Dai, Weizhi
    Hu, Xi'en
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 1993, 7 (03): : 214 - 220
  • [3] A STUDY ON MASS TRANSFER IN PULSED SIEVE-PLATE EXTRACTION COLUMN
    钱宇
    费维扬
    汪家鼎
    JournalofChemicalIndustryandEngineering, 1989, (02) : 218 - 228
  • [4] A simplified correlation of mass transfer in a pulsed sieve plate extraction column
    Luo, GS
    Li, HB
    Fei, WY
    Wang, JD
    CHEMICAL ENGINEERING & TECHNOLOGY, 1998, 21 (10) : 823 - 827
  • [5] Mass transfer studies in an L-shaped pulsed sieve-plate extraction column
    Rafiei, Vahid
    Safdari, Jaber
    Moradi, Sadegh
    Mallah, Mohammad H.
    SEPARATION SCIENCE AND TECHNOLOGY, 2018, 53 (17) : 2756 - 2768
  • [6] Mass Transfer Characteristics in a Standard Pulsed Sieve-Plate Extraction Column
    Jiao Caishan
    Ma Shuai
    Song Qiong
    3RD INTERNATIONAL CONFERENCE ON ASIAN NUCLEAR PROSPECTS (ANUP2012), 2013, 39 : 348 - 357
  • [7] Mass transfer performance in a coalescence-dispersion pulsed sieve plate extraction column
    Li, HB
    Luo, GS
    Fei, WY
    Wang, JD
    CHEMICAL ENGINEERING JOURNAL, 2000, 78 (2-3) : 225 - 229
  • [8] Arsenic Removal from Natural Gas Condensate using a Pulsed Sieve Plate Column and Mass Transfer Efficiency
    Chaturabul, Srestha
    Wannachod, Pharannalak
    Rojanasiraprapa, Bongkotch
    Summakasipong, Supat
    Lothongkum, Anchaleeporn W.
    Pancharoen, Ura
    SEPARATION SCIENCE AND TECHNOLOGY, 2012, 47 (03) : 432 - 439
  • [9] Enzyme mass transfer coefficient in a sieve plate extraction column
    Bhawsar, P.C.M.
    Pandit, A.B.
    Sawant, S.B.
    Joshi, J.B.
    1600, Elsevier Sequoia SA, Lausanne, Switzerland (55): : 1 - 2
  • [10] HOLDUP STUDIES IN A PULSED SIEVE-PLATE SOLVENT EXTRACTION COLUMN
    SEHMEL, GA
    BABB, AL
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1963, 2 (01): : 38 - &