Local hemodynamic disturbance accelerates early thrombosis of small-caliber expanded polytetrafluoroethylene grafts

被引:9
作者
Lu, S. [1 ,2 ]
Sun, X. [1 ,2 ]
Zhang, P. [3 ]
Yang, L. [4 ]
Gong, F. [3 ]
Wang, C. [1 ,2 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Shanghai Inst Cardiovasc Dis, Shanghai 200032, Peoples R China
[2] Fudan Univ, Zhongshan Hosp, Dept Cardiovasc Surg, Shanghai 200032, Peoples R China
[3] E China Univ Sci & Technol, Sch Mat Sci & Engn, Shanghai 200237, Peoples R China
[4] Fudan Univ, EYE & ENT Hosp, Expt Res Ctr, Shanghai 200032, Peoples R China
来源
PERFUSION-UK | 2013年 / 28卷 / 05期
基金
中国国家自然科学基金;
关键词
coronary artery disease; small-caliber; grafting; hemodynamic disturbance; thrombosis; COMPUTATIONAL ANALYSIS; VASCULAR GRAFTS; ENDOTHELIALIZATION; IMMOBILIZATION; FIBRONECTIN; TITANIUM; PEPTIDE; HEPARIN;
D O I
10.1177/0267659113489330
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Small-caliber expanded polytetrafluoroethylene (ePTFE) grafts cannot be used widely in the clinical situation because of early thrombosis and occlusion. This unsolved and under-recognized problem warrants further investigation. Methods: Grafts of uncoated ePTFE (n = 6) and anti-CD34-coated ePTFE (n = 6) were implanted unilaterally into the carotid artery in 12 domestic pigs. Ultrasonography was used to test the proximal and distal anastomotic stoma morphology, diameters and blood velocities. A thrombosis instrument was used to examine the blood coagulation state. After seven days, the pigs were sacrificed and the implanted grafts were excised for general and histological analysis. Computational fluid dynamics was used to investigate the blood flow fields of the implanted grafts and to calculate parameters that might be indicative of thrombosis. Results: Thrombosis was detected in 10 of 12 (83.3%) implanted ePTFE grafts, 5 in uncoated grafts and 5 in anti-CD34-coated grafts. Endothelial cell coverage was observed in both uncoated and anti-CD34-coated grafts. No obvious abnormalities in anastomotic stoma or blood coagulation state were observed. Computer-based local hemodynamic simulation showed the low flexibility of synthetic ePTFE grafts caused obvious coarctation. Local wall pressure, velocity and wall shear stress were much higher than in the contralateral normal vessel. Conclusions: The patency of small-caliber ePTFE grafts for clinical use is impaired by early thrombosis due to mixed causes. Local hemodynamic disturbance was the most powerful predictor of early thrombosis. Decreasing local hemodynamic disturbance, improving the quality of anastomotic stoma, selecting reasonable anticoagulation strategies and promoting rapid endothelialization may increase the long-term patency of small-caliber vascular grafts.
引用
收藏
页码:440 / 448
页数:9
相关论文
共 21 条
[1]  
Chlupac J, 2010, Rozhl Chir, V89, P85
[2]  
Cines DB, 1998, BLOOD, V91, P3527
[3]   Development and evaluation of a novel decellularized vascular xenograft [J].
Conklin, BS ;
Richter, ER ;
Kreutziger, KL ;
Zhong, DS ;
Chen, C .
MEDICAL ENGINEERING & PHYSICS, 2002, 24 (03) :173-183
[4]   Improving arterial prosthesis neo-endothelialization: Application of a proactive VEGF construct onto PTFE surfaces [J].
Crombez, M ;
Chevallier, P ;
Gaudreault, RC ;
Petitclerc, E ;
Mantovani, D ;
Laroche, G .
BIOMATERIALS, 2005, 26 (35) :7402-7409
[5]   Improved endothelialization and reduced thrombosis by coating a synthetic vascular graft with fibronectin and stem cell homing factor SDF-1α [J].
De Visscher, G. ;
Mesure, L. ;
Meuris, B. ;
Ivanova, A. ;
Flameng, W. .
ACTA BIOMATERIALIA, 2012, 8 (03) :1330-1338
[6]   Impregnation of basic fibroblast growth factor on a microporous small caliber graft enhances vascularization [J].
Doi, K ;
Satoh, S ;
Oka, T ;
Matsuda, T .
ASAIO JOURNAL, 1996, 42 (05) :M394-M398
[7]   Computational Fluid Dynamics Analysis of Thrombosis Potential in Left Ventricular Assist Device Drainage Cannulae [J].
Fraser, Katharine H. ;
Zhang, Tao ;
Taskin, M. Ertan ;
Griffith, Bartley P. ;
Wu, Zhongjun J. .
ASAIO JOURNAL, 2010, 56 (03) :157-163
[8]  
Hassan T, 2003, AM J NEURORADIOL, V24, P1075
[9]   Heparin immobilization reduces thrombogenicity of small-caliber expanded polytetrafluoroethylene grafts [J].
Heyligers, JMM ;
Verhagen, HJM ;
Rotmans, JI ;
Weeterings, C ;
de Groot, PG ;
Moll, FL ;
Lisman, T .
JOURNAL OF VASCULAR SURGERY, 2006, 43 (03) :587-591
[10]   Computational analysis of effects of external carotid artery flow and occlusion on adverse carotid bifurcation hemodynamics [J].
Hyun, S ;
Kleinstreuer, C ;
Archie, JP .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (06) :1248-1254