Assessment of Needle Guidance Devices for Their Potential to Reduce Fluoroscopy Time and Operator Hand Dose during C-Arm Cone-Beam Computed Tomography-guided Needle Interventions

被引:15
作者
Kroes, Maarten W. [1 ]
Busser, Wendy M. H. [1 ]
Futterer, Jurgen J. [1 ]
Arntz, Mark J. [1 ]
Janssen, Caroline M. M. [1 ]
Hoogeveen, Yvonne L. [1 ]
de Lange, Frank [1 ]
Kool, Leo J. Schultze [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Radiol, NL-6525 GA Nijmegen, Netherlands
关键词
RADIOFREQUENCY ABLATION; PATH OVERLAY; LUNG-BIOPSY; RADIOLOGY; RADIATION; NAVIGATION; PLACEMENT; ACCURACY; SYSTEM; SUITE;
D O I
10.1016/j.jvir.2013.02.037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess whether the use of needle guidance devices can reduce fluoroscopy time and operator hand dose during cone-beam computed tomography guided needle interventions. Materials and Methods: The freehand technique was compared With techniques employing two distinct needle holders and a ceiling-mounted laser guidance technique. Laser guidance was used either alone or in combination with needle holders. Four interventional radiologists were instructed to reach predetermined targets in an abdominal phantom using these techniques. Bach operator used all six techniques three times. Fluoroscopy time, procedure time, operator hand dose, and needle tip deviation were obtained for all simulated needle interventions. All data are presented as median (ranges). Results: All procedures were successfully completed within 2-4 minutes, resulting in a deviation from target of 0.8 mm (0-4.7). In freehand procedures, the fluoroscopy time to reach the target was 50 seconds (31-98 s). Laser guidance, used alone or in combination with needle holders, reduced fluoroscopy time to 31 seconds (14-68 s) (P < .02). The operator hand dose in freehand procedures was 275 mu Sv (20-603 mu Sv). Laser guidance alone or in combination with needle holders resulted in a reduction of-the hand dose to < 36 mu Sv (5-82 mu Sv) per procedure (P < .001). There were no statistically significant effects on hand dose levels or fluoroscopy time when the needle holders were employed alone. Conclusions: Compared with the freehand technique, all three tested needle guidance devices performed with equivalent efficiency in terms of accuracy and procedure time. Only the addition of laser guidance was found to reduce both fluoroscopy time and,operator hand dose.
引用
收藏
页码:901 / 906
页数:6
相关论文
共 24 条
[1]   Real-Time 3D Fluoroscopy Guidance During Needle Interventions: Technique, Accuracy, and Feasibility [J].
Braak, S. J. ;
van Strijen, M. J. L. ;
van Leersum, M. ;
van Es, H. W. ;
van Heesewijk, J. P. M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) :W445-W451
[2]   Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy [J].
Braak, Sicco J. ;
Herder, Gerarda J. M. ;
van Heesewijk, Johannes P. M. ;
van Strijen, Marco J. L. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (06) :1414-1421
[3]   Effective Dose during Needle Interventions: Cone-beam CT Guidance Compared with Conventional CT Guidance [J].
Braak, Sicco J. ;
van Strijen, Marco J. L. ;
van Es, Hendrik W. ;
Nievelstein, Rutger A. J. ;
van Heesewijk, Johannes P. M. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (04) :455-461
[4]   Multicenter evaluation of a new laser guidance system for computed tomography intervention [J].
Brabrand, K ;
Aalokken, TM ;
Krombach, GA ;
Günther, RW ;
Tariq, R ;
Magnusson, A ;
Lindgren, PG .
ACTA RADIOLOGICA, 2004, 45 (03) :308-312
[5]   Percutaneous Radiofrequency Ablation of Osteoid Osteomas with Use of Real-Time Needle Guidance for Accurate Needle Placement: A Pilot Study [J].
Busser, Wendy M. H. ;
Hoogeveen, Yvonne L. ;
Veth, Rene P. H. ;
Schreuder, H. W. Bart ;
Balguid, Angelique ;
Renema, W. KlaasJan ;
SchultzeKool, Leo J. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (01) :180-183
[6]   C-Arm Cone-Beam CT-Guided Percutaneous Transthoracic Lung Biopsy: Usefulness in Evaluation of Small Pulmonary Nodules [J].
Hwang, Hye Sun ;
Chung, Myung Jin ;
Lee, Ju Won ;
Shin, Sung Wook ;
Lee, Kyung Soo .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) :W400-W407
[7]   Real-Time 3D Fluoroscopy-Guided Large Core Needle Biopsy of Renal Masses: A Critical Early Evaluation According to the IDEAL Recommendations [J].
Kroeze, Stephanie G. C. ;
Huisman, Merel ;
Verkooijen, Helena M. ;
van Diest, Paul J. ;
Bosch, J. L. H. Ruud ;
van den Bosch, Maurice A. A. J. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (03) :680-685
[8]   Potential of a new laser target system for percutaneous CT-guided nerve blocks: technical note [J].
Krombach, GA ;
Schmitz-Rode, T ;
Wein, BB ;
Meyer, J ;
Wildberger, JE ;
Brabant, K ;
Gunther, RW .
NEURORADIOLOGY, 2000, 42 (11) :838-841
[9]   C-arm cone beam computed tomography needle path overlay for image-guided procedures of the spine and pelvis [J].
Leschka, Simon C. ;
Babic, Drazenko ;
El Shikh, Samer ;
Wossmann, Christine ;
Schumacher, Martin ;
Taschner, Christian A. .
NEURORADIOLOGY, 2012, 54 (03) :215-223
[10]   Computed-tomography-guided punctures using a new guidance device [J].
Magnusson, A ;
Radecka, E ;
Lönnemark, M ;
Raland, H .
ACTA RADIOLOGICA, 2005, 46 (05) :505-509