Magnetic NDT and Computer Modeling of Steel Rope Deterioration in Suspended Bridges

被引:2
|
作者
Vorontsov, Alexander [1 ]
Zhirnov, Alexander [1 ]
Sukhorukov, Dmitry [1 ]
机构
[1] Intron Plus Ltd, Moscow 111524, Russia
来源
DAMAGE ASSESSMENT OF STRUCTURES X, PTS 1 AND 2 | 2013年 / 569-570卷
关键词
stay wire rope; magnetic testing; deterioration; breaking load simulation; safety factor;
D O I
10.4028/www.scientific.net/KEM.569-570.1101
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A combined approach to strength assessment of stay ropes in suspension bridges is considered. The rope working condition is analyzed by in-situ magnetic testing, computational assessment of ultimate breaking load and evaluation of residual margin of safety. The diagnostic parameters - distributed and/or local faults in wires - are used as input data for mechanical model of rope structure. The model allows calculating the stresses in each wire, simulating the degradation process and evaluating the rope breaking tensile load. The safety factor of deteriorated rope is considered as a generalized parameter that specifies the rope safe operation as an element of bridge stay arrangement. Examples of integrity analysis of stranded stay ropes and locked coil stay ropes are presented.
引用
收藏
页码:1101 / 1108
页数:8
相关论文
共 50 条
  • [1] Steel wire rope NDT: New instruments
    Sukhorukov, VV
    PREVIOUS EXPERIENCE AND CURRENT INNOVATIONS IN NON-DESTRUCTIVE TESTING, 2001, : 225 - 230
  • [2] Steel Rope Diagnostics by Magnetic NDT: From Defect Detection to Automated Condition Monitoring
    Sukhorukov, Vasily V.
    MATERIALS EVALUATION, 2021, 79 (05) : 439 - 445
  • [3] Deterioration and assessment of steel bridges
    Ryjacek, Pavel
    Macho, Martin
    Stancik, Vojtech
    Polak, Michal
    MAINTENANCE, MONITORING, SAFETY, RISK AND RESILIENCE OF BRIDGES AND BRIDGE NETWORKS, 2016, : 347 - 347
  • [4] Structural deterioration assessment for steel bridges
    Farhey, Daniel N.
    Thakur, Aniruddha M.
    Buchanan, Relva C.
    Emin Aktan, A.
    Jayaraman, Narayanan
    Journal of Bridge Engineering, 1997, 2 (03): : 116 - 124
  • [5] Evaluation of corrosion deterioration of steel bridges
    Matsumoto, M
    Maruyama, D
    Okada, S
    STRUCTURAL SAFETY AND RELIABILITY, VOLS. 1-3, 1998, : 1159 - 1164
  • [6] COMPUTER MODELING AND RELIABILITY EVALUATION OF STEEL THROUGH TRUSS BRIDGES
    TRAUTNER, JJ
    FRANGOPOL, DM
    STRUCTURAL SAFETY, 1990, 7 (2-4) : 255 - 267
  • [7] Magnetic NDT of steel wire ropes
    Sukhorukov, VV
    4TH INTERNATIONAL CONFERENCE OF SLOVENIAN SOCIETY FOR NONDESTRUCTIVE TESTING - APPLICATION OF CONTEMPORARY NONDESTRUCTIVE TESTING IN ENGINEERING, CONFERENCE PROCEEDINGS, 1997, : 229 - 237
  • [8] Use of magnetic NDT to determine the lay length of a stranded wire rope
    Ridge, IML
    Tytko, AA
    INSIGHT, 2001, 43 (12) : 806 - 813
  • [9] Multi-objective optimization of polyester-rope and steel-rope suspended footbridgese
    Segal, Edward M.
    Rhode-Barbarigos, Landolf
    Adriaenssens, Sigrid
    Coelho, Rajan D. Filomeno
    ENGINEERING STRUCTURES, 2015, 99 : 559 - 567
  • [10] Diagnostics system of paint film deterioration of steel bridges
    Anon
    Ishikawajima-Harima Giho/IHI Engineering Review, 2004, 44 (01): : 34 - 37