Theoretical Comparison of the Iodine Quantification Accuracy of Two Spectral CT Technologies

被引:16
作者
Bornefalk, Hans [1 ]
Persson, Mats [1 ]
机构
[1] AlbaNova Univ Ctr, Royal Inst Technol, Dept Phys, SE-10691 Stockholm, Sweden
关键词
Dual energy computed tomography (CT); iodine quantification; photon counting multibin CT; spectral CT; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; MATERIAL DECOMPOSITION; NOISE; PERFORMANCE; STATISTICS; SYSTEM; SNR;
D O I
10.1109/TMI.2013.2290198
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We compare the theoretical limits of iodine quantification for the photon counting multibin and dual energy technologies. Dual energy systems by necessity have to make prior assumptions in order to quantify iodine. We explicitly allow the multibin system to make the same assumptions and also allow them to be wrong. We isolate the effect of technology from imperfections and implementation issues by assuming both technologies to be ideal, i.e., without scattered radiation, unity detection efficiency and perfect energy response functions, and by applying the Cramer-Rao lower bound methodology to assess the quantification accuracy. When priors are wrong the maximum likelihood estimates will be biased and the mean square error of the quantification error is a more appropriate figure of merit. The evaluation assumes identical X-ray spectra for both methodologies and for that reason a sensitivity analysis is performed with regard to the assumed X-ray spectrum. We show that when iodine is quantified over regions of interest larger than 6 cm, multibin systems benefit by independent estimation of three basis functions. For smaller regions of interest multibin systems can increase quantification accuracy by making the same prior assumptions as dual energy systems.
引用
收藏
页码:556 / 565
页数:10
相关论文
共 44 条
  • [11] Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment
    Boone, JM
    [J]. RADIOLOGY, 1999, 213 (01) : 23 - 37
  • [12] Synthetic Hounsfield units from spectral CT data
    Bornefalk, Hans
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (07) : N83 - N87
  • [13] XCOM intrinsic dimensionality for low-Z elements at diagnostic energies
    Bornefalk, Hans
    [J]. MEDICAL PHYSICS, 2012, 39 (02) : 654 - 657
  • [14] Task-based weights for photon counting spectral x-ray imaging
    Bornefalk, Hans
    [J]. MEDICAL PHYSICS, 2011, 38 (11) : 6065 - 6073
  • [15] Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses
    Chandarana, Hersh
    Megibow, Alec J.
    Cohen, Benjamin A.
    Srinivasan, Ramya
    Kim, Danny
    Leidecker, Christianne
    Macari, Michael
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : W693 - W700
  • [16] HANSON K M, 1979, Medical Physics (Woodbury), V6, P441, DOI 10.1118/1.594534
  • [17] Hsieh J, 2003, COMPUT TOMOGR, DOI DOI 10.1117/3.2197756
  • [18] ICRU, 1989, ICRU REP 44
  • [19] Material differentiation by dual energy CT: initial experience
    Johnson, Thorsten R. C.
    Krauss, Bernhard
    Sedlmair, Martin
    Grasruck, Michael
    Bruder, Herbert
    Morhard, Dominik
    Fink, Christian
    Weckbach, Sabine
    Lenhard, Miriam
    Schmidt, Bernhard
    Flohr, Thomas
    Reiser, Maximilian F.
    Becker, Christoph R.
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (06) : 1510 - 1517
  • [20] Kalender W.A., 2005, COMPUT TOMOGR, V2nd