Comparisons of Microleakage and Scanning Electron Microscope SEM Analyzes of The Use of Different Pulp Coverage Materials

被引:0
|
作者
Yavuz, Yasemin [1 ,5 ]
Kotanli, Sedef [2 ]
Dogan, Mehmet Sinan [3 ]
Dogan, Kemal [4 ]
机构
[1] Harran Univ, Fac Dent, Dept Restorat Dent, TR-63300 Sanliurfa, Turkey
[2] Harran Univ, Fac Dent, Dept Maxillo Facial Radiol, TR-63300 Sanliurfa, Turkey
[3] Harran Univ, Fac Dent, Dept Pediat Dent, TR-63300 Sanliurfa, Turkey
[4] Harran Univ, Sci & Technol Applicat & Res Ctr, TR-63300 Sanliurfa, Turkey
[5] Harran Univ, Fac Dent, Dept Restorat Dent, Sanliurfa, Turkey
来源
MAKARA JOURNAL OF HEALTH RESEARCH | 2022年 / 26卷 / 02期
关键词
calcium silicate; gap; microleakage; pulp; MARGINAL ADAPTATION; BIODENTINE(TM);
D O I
10.7454/msk.v26i2.1396
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The aim of this study was to compare three different pulp coverage materials with calcium silicate content considering microleakage in the cavity floor and evaluate the gaps with a stereomicroscope and scanning electron microscope SEM.Methods: A total of 40 human molar teeth were used in this study, and class V (4 mm mesio-distal x 3 mm gingivo-occlusal x 3 mm depth) cavities were prepared. The samples were divided into four groups (N = 10), including NeoPutty(Nusmile), Biodentin (Septodont), and TheraCal PT (Bisco). All groups were restored using Single Bond Universal adhesive and Filtek Z250 (3M ESPE). The 0.5% basic fuchsin dye leakage was examined at 40x magnification under a stereomicroscope. SEM analysis revealed that the magnification was fixed at 1.00 KX on all the images. The gaps between the pulp coverage material and the cavity floor dentin were measured from four different points.Results: The different microleakage scores were statistically significant (p < 0.05) when the pulp coverage materials were compared considering microleakage.Conclusions: Within the scope of this study, the biocompatible pulp coating materials NeoPutty and Biodentin showed the least microleakage at the cavity floor and the smallest gaps on the dentin material combined surfaces. By contrast, TheraCal showed increased microleakage and large gaps.
引用
收藏
页码:140 / 145
页数:7
相关论文
共 50 条
  • [31] SEM (SCANNING ELECTRON-MICROSCOPE) STUDIES OF AORTIC STRUCTURE
    CHISOLM, GM
    GAINER, JL
    STONER, GE
    ANGIOLOGICA, 1973, 10 (01): : 10 - 14
  • [32] Quantitative measurement of electromagnetic distortions in scanning electron microscope (SEM)
    Pluska, Mariusz
    Oskwarek, Lukasz
    Rak, Remigiusz
    Czerwinski, Andrzej
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 1520 - +
  • [33] SCANNING ELECTRON-MICROSCOPE (SEM) POSITIVE PRINT PHOTOGRAPHY
    ROSAUER, EA
    AMENSON, JL
    OPTICAL ENGINEERING, 1978, 17 (04) : 422 - 424
  • [34] POSSIBILITIES OF THE USE OF THE SCANNING ELECTRON-MICROSCOPE AND OF THE SEM-EDXRA-METHOD IN SOIL INVESTIGATIONS
    PARTAY, G
    AGROKEMIA ES TALAJTAN, 1980, 29 (3-4): : 543 - 566
  • [35] Examining composite materials with the scanning electron microscope
    DAVIS LW
    LONG JR
    1600, (12):
  • [36] TOTAL MATERIALS CHARACTERIZATION WITH SCANNING ELECTRON MICROSCOPE
    JOHARI, O
    RESEARCH-DEVELOPMENT, 1971, 22 (07): : 12 - &
  • [37] SCANNING ELECTRON-MICROSCOPE - PRINCIPLES, APPARATUS, USE IN CHEMISTRY OF SOLIDS AND MATERIALS
    MURAT, M
    CHIMICA & L INDUSTRIA, 1975, 57 (02): : 99 - 113
  • [38] Applications of the Scanning Electron Microscope in Materials Science
    Minkoff, I.
    JOURNAL OF MATERIALS SCIENCE, 1967, 2 (04) : 388 - 394
  • [40] Scanning Electron Microscope (SEM) Evaluation of Composite Surface Irradiated by Different Powers of Er:YAG Laser
    Etemadi, Ardavan
    Shahabi, Sima
    Chiniforush, Nasim
    Pordel, Edris
    Azarbayejani, Zahra
    Heidari, Soolmaz
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2015, 6 (02) : 80 - 84