Digital flat-panel X-ray technology based on cesium iodide and amorphous silicon:: experimental studies and preliminary clinical results.

被引:0
作者
Strotzer, M [1 ]
Gmeinwieser, J [1 ]
Völk, M [1 ]
Fründ, R [1 ]
Feuerbach, S [1 ]
机构
[1] Klinikum Univ Regensburg, Inst Rontgendiagnostik, D-93042 Regensburg, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1999年 / 170卷 / 01期
关键词
radiography; digital; technology; amorphous silicon;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Experimental and clinical evaluation of a digital flat-panel X-ray system based on cesium iodide (CsI) and amorphous silicon (a-Si). Methods: Performance of a prototype detector was compared with conventional screen-film radiography (SFR) using several phantom studies. Foreign bodies, fractures, osteolyses, and pulmonary lesions were analyzed. Additionally, 120 patients were studied prospectively, resulting in 400 comparative X-ray studies. The fiat-panel detector was exposed with standard dose and with a dose reduction of up to 75%. Detector size was 15 x 15 cm, pixel matrix was 1 x Ik with a pixel size of 143 mu m. Modulation-transfer function was determined to be 18% at the maximum spatial resolution of 3.5 Ip/mm. Results: The diagnostic results achieved with the digital detector were similar to those of conventional SFR; even at reduced radiation exposure. A potential for dose reduction was observed: 50% with respect to osteoarthrosis and fractures, end 75% for determining bony alignment. Discussion: This new technology can be used in thoracic and skeletal radiography. A significant dose reduction is possible, depending on the suspected disease.
引用
收藏
页码:66 / 72
页数:7
相关论文
共 30 条
  • [1] Chest radiography: Optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector
    Dobbins, JT
    Samei, E
    Chotas, HG
    Warp, RJ
    Baydush, AH
    Floyd, CE
    Ravin, CE
    RADIOLOGY, 2003, 226 (01) : 221 - 230
  • [2] Selenium-based amorphous silicon flat-panel digital X-ray imager for protein crystallography
    Sultana, Afrin
    Karim, K. S.
    Rowlands, J. A.
    CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2008, 33 (3-4): : 139 - 143
  • [3] Contrast-detail phantom study for X-ray spectrum optimization regarding chest radiography using a cesium iodide -: Amorphous silicon flat-panel detector
    Hamer, OW
    Völk, M
    Zorger, N
    Borisch, I
    Büittner, R
    Feuerbach, S
    Strotzer, M
    INVESTIGATIVE RADIOLOGY, 2004, 39 (10) : 610 - 618
  • [4] Digital radiography with a large-area, amorphous-silicon, flat-panel X-ray detector system
    Spahn, M
    Strotzer, M
    Völk, M
    Böhm, S
    Geiger, B
    Hahm, G
    Feuerbach, S
    INVESTIGATIVE RADIOLOGY, 2000, 35 (04) : 260 - 266
  • [5] Simulated bone erosions in a hand phantom:: Detection with conventional screen-film technology versus cesium iodide-amorphous silicon flat-panel detector
    Strotzer, M
    Völk, M
    Wild, T
    von Landenberg, P
    Feuerbach, S
    RADIOLOGY, 2000, 215 (02) : 512 - 515
  • [6] Flat-panel X-ray detector using amorphous silicon technology - Reduced radiation dose for the detection of foreign bodies
    Volk, M
    Strotzer, M
    Gmeinwieser, J
    Alexander, J
    Frund, R
    Seitz, J
    Manke, C
    Spahn, M
    Feuerbach, S
    INVESTIGATIVE RADIOLOGY, 1997, 32 (07) : 373 - 377
  • [7] Experimental evaluation of a novel CdZnTe flat-panel X-ray detector for digital radiography and fluoroscopy
    Tokuda, S
    Adachi, S
    Sato, T
    Yoshimuta, T
    Nagata, H
    Uehara, K
    Izumi, Y
    Teranuma, O
    Yamada, S
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 140 - 147
  • [8] Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography
    Hennigs, SP
    Garmer, M
    Jaeger, HJ
    Classen, R
    Jacobs, A
    Gissler, HM
    Christmann, A
    Mathias, K
    EUROPEAN RADIOLOGY, 2001, 11 (09) : 1688 - 1696
  • [9] Experimental evaluation of a-Se and CdTe flat-panel X-ray detectors for digital radiography and fluoroscopy
    Adachi, S
    Hori, N
    Sato, K
    Tokuda, S
    Sato, T
    Uehara, K
    Izumi, Y
    Nagata, H
    Yoshimura, Y
    Yamada, S
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 38 - 47
  • [10] Image quality evaluation of a selenium-based flat-panel digital x-ray detector system based on animal studies
    Yamada, S
    Umazaki, H
    Takahashi, A
    Honda, M
    Shiraishi, K
    Rudin, S
    Bednarek, DR
    Yang, CYJ
    Wang, Z
    Gopal, A
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 429 - 436