C1 Pedicle Screws Versus C1 Lateral Mass Screws Comparisons of Pullout Strengths and Biomechanical Stabilities

被引:92
作者
Ma, Xiang-Yang [1 ]
Yin, Qing-Shui [1 ]
Wu, Zeng-Hui [1 ]
Xia, Hong [1 ]
Liu, Jing-Fa [1 ]
Xiang, Ming [2 ]
Zhao, Wei-Dong [3 ]
Zhong, Shi-Zhen [3 ]
机构
[1] Guangzhou Liu Hua Qiao Hosp, Dept Orthoped, Guangzhou 510010, Guangdong, Peoples R China
[2] Shenzhen Shekou Peoples Hosp, Dept Orthoped, Shenzhen, Guangdong, Peoples R China
[3] So Med Univ, Dept Anat, Guangzhou, Guangdong, Peoples R China
关键词
pullout strength; biomechanical stability; atlantoaxial fixation; atlas; pedicle screw; lateral mass screw; unicortical fixation; bicortical fixation; POSTERIOR ATLANTOAXIAL FIXATION; STABILIZATION METHODS; HYPOGLOSSAL NERVE; CERVICAL VERTEBRA; PLATE FIXATION; TECHNICAL NOTE; PLACEMENT; ATLAS; INSTABILITY; FUSION;
D O I
10.1097/BRS.0b013e318193a21b
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. In vitro biomechanical study. Objective. To compare the pullout strengths and the biomechanical stabilities afforded by C1 lateral mass screws and C1 pedicle screws using bicortical and unicortical fixation techniques. Summary of Background Data. Posterior screw fixation techniques in the atlas including C1 lateral mass screw and C1 pedicle screw. The shortcomings of C1 lateral mass screw technique and potential risks of bicortical fixation method were recently described; C1 pedicle screw technique with unicortical fixation might overcome these anatomic and clinical drawbacks. However, it is unknown whether the biomechanical characteristics of unicortical C1 pedicle screw are comparable with that of bicortical C1 lateral mass screw. Methods. Bicortical or unicortical C1 pedicle screws and C1 lateral mass screws were inserted into 12 adult fresh human C1 specimens. Pullout strength was evaluated using a material testing machine. The construct's stability of bicortical C1 lateral mass screws or unicortical C1 pedicle screws incorporating unicortical C2 pedicle screws was compared with bilateral transarticular screws using another 6 fresh cervical cadaver spines. Pullout strength and biomechanical stability differences were compared statistically. Results. Bicortical C1 pedicle screws provided the biggest pullout strength (1757.0 +/- 318.7 N) of all 4 methods, whereas unicortical C1 lateral mass screws provided the weakest(794.5 +/- 314.8 N). However, there were no statistically significant differences between bicortical C1 lateral mass screws (1243.8 +/- 350.0 N) and unicortical C1 pedicle screws (1192.5 +/- 172.6 N). Furthermore, there was no statistically significant difference of biomechanical construct stability between unicortical C1 pedicle screw-rod constructs and bicortical C1 lateral mass screw-rod constructs. Conclusion. C1 pedicle screws are stiffer than C1 lateral mass screws. Unicortical C1 pedicle screw provided the same pullout resistance and three-dimensional stability as bicortical C1 lateral mass fixation. Although lateral mass screw placement into C1 requires bicortical purchase, pedicle screw insertion into the atlas only requires unicortical fixation.
引用
收藏
页码:371 / 377
页数:7
相关论文
共 50 条
[1]  
AbouMadawi A, 1997, J BONE JOINT SURG BR, V79B, P820
[2]   Posterior atlantoaxial transpedicular screw and plate fixation - Technical note [J].
Chen, JF ;
Wu, CT ;
Lee, SC ;
Lee, ST .
JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (03) :386-392
[3]   C1 anatomy and dimensions relative to lateral mass screw placement [J].
Christensen, David M. ;
Eastlack, Robert K. ;
Lynch, James J. ;
Yaszemski, Michael J. ;
Currier, Bradford L. .
SPINE, 2007, 32 (08) :844-848
[4]   Arteriovenous fistula as a complication of C1-2 transarticular screw fixation - Case report and review of the literature [J].
Coric, D ;
Branch, CL ;
Wilson, JA ;
Robinson, JC .
JOURNAL OF NEUROSURGERY, 1996, 85 (02) :340-343
[5]   C1-C2 POSTERIOR CERVICAL FUSION - LONG-TERM EVALUATION OF RESULTS AND EFFICACY [J].
COYNE, TJ ;
FEHLINGS, GM ;
WALLACE, MC ;
BERNSTEIN, M ;
TATOR, CH .
NEUROSURGERY, 1995, 37 (04) :688-692
[6]   Anatomic relationship of the internal carotid artery to the C1 vertebra: A case report of cervical reconstruction for chordoma and pilot study to assess the risk of screw fixation of the atlas [J].
Currier, BL ;
Todd, LT ;
Maus, TP ;
Fisher, DR ;
Yaszemski, MJ .
SPINE, 2003, 28 (22) :E461-E467
[7]  
Currier BL., 2004, CURR OPIN ORTHOP, V15, P184, DOI 10.1097/01.bco.0000127817.76306.61
[8]   SURGICAL-MANAGEMENT OF ATLANTOAXIAL NONUNIONS [J].
DICKMAN, CA ;
SONNTAG, VKH .
JOURNAL OF NEUROSURGERY, 1995, 83 (02) :248-253
[9]   Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis [J].
Dickman, CA ;
Sonntag, VKH .
NEUROSURGERY, 1998, 43 (02) :275-280
[10]   THE QUANTITATIVE ANATOMY OF THE ATLAS [J].
DOHERTY, BJ ;
HEGGENESS, MH .
SPINE, 1994, 19 (22) :2497-2500