A sensitive and selective nitrite sensor based on a glassy carbon electrode modified with gold nanoparticles and sulfonated graphene

被引:63
|
作者
Li, Su-Juan [1 ]
Zhao, Guo-Yan [1 ]
Zhang, Rong-Xia [1 ]
Hou, Ya-Li [1 ]
Liu, Lin [1 ]
Pang, Huan [1 ]
机构
[1] Anyang Normal Univ, Key Lab Clearer Energy & Funct Mat Henan Prov, Coll Chem & Chem Engn, Anyang 455000, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Gold nanoparticles; Graphene; Nitrite; Amperometry; Sensor; ION CHROMATOGRAPHY; WATER SAMPLES; OXIDATION; NANOCOMPOSITE; SPECTROPHOTOMETRY; NANOSHEETS; NANOTUBES; MEDIA; OXIDE;
D O I
10.1007/s00604-013-0999-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe a highly sensitive and selective amperometric sensor for the determination of nitrite. A glassy carbon electrode was modified with a composite made from gold nanoparticles (AuNPs) and sulfonated graphene (SG). The modified electrode displays excellent electrocatalytic activity in terms of nitrite oxidation by giving much higher peak currents (at even lower oxidation overpotential) than those found for the bare electrode, the AuNPs-modified electrode, and the SG-modified electrode. The sensor has a linear response in the 10 mu M to 3.96 mM concentration range, a very good detection sensitivity (45.44 mu A mM(-1)), and a lower detection limit of 0.2 mu M of nitrite. Most common ions and many environmental organic pollutants do not interfere. The sensor was successfully applied to the determination of nitrite in water samples, and the results were found to be consistent with the values obtained by spectrophotometry.
引用
收藏
页码:821 / 827
页数:7
相关论文
共 50 条
  • [1] A sensitive and selective nitrite sensor based on a glassy carbon electrode modified with gold nanoparticles and sulfonated graphene
    Su-Juan Li
    Guo-Yan Zhao
    Rong-Xia Zhang
    Ya-Li Hou
    Lin Liu
    Huan Pang
    Microchimica Acta, 2013, 180 : 821 - 827
  • [2] Selective and Sensitive Nitrite Sensor Based on Glassy Carbon Electrode Modified by Silver Nanochains
    Shaikh, Tayyaba
    Ibupoto, Zaffar Hussain
    Talpur, Farah N.
    Sirajuddin
    Khaskheli, Abdul Rauf
    Agheem, Muhammad H.
    Siddiqui, Samia
    Tahira, Aneela
    Willander, Magnus
    Yu, Cong
    ELECTROANALYSIS, 2017, 29 (02) : 415 - 422
  • [3] A sensitive and selective electrochemical nitrite sensor based on a glassy carbon electrode modified with cobalt phthalocyanine-supported Pd nanoparticles
    Song, Xueying
    Gao, Li
    Li, Yamin
    Mao, Liqun
    Yang, Jing-He
    ANALYTICAL METHODS, 2017, 9 (21) : 3166 - 3171
  • [4] Graphene Nanosheets Modified Glassy Carbon Electrode as a Highly Sensitive and Selective Voltammetric Sensor for Rutin
    Du, Haijun
    Ye, Jianshan
    Zhang, Jiaqi
    Huang, Xiaodan
    Yu, Chengzhong
    ELECTROANALYSIS, 2010, 22 (20) : 2399 - 2406
  • [5] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Yazhen Wang
    Bin Song
    Junhui Xu
    Shengshui Hu
    Microchimica Acta, 2015, 182 : 711 - 718
  • [6] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Wang, Yazhen
    Song, Bin
    Xu, Junhui
    Hu, Shengshui
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 711 - 718
  • [7] A sensitive hydrazine electrochemical sensor based on electrodeposition of gold nanoparticles on choline film modified glassy carbon electrode
    Li, Jing
    Xie, Huaqing
    Chen, Lifei
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 153 (01) : 239 - 245
  • [8] A novel nitrite sensor based on graphene/polypyrrole/chitosan nanocomposite modified glassy carbon electrode
    Ye, Daixin
    Luo, Liqiang
    Ding, Yaping
    Chen, Qiang
    Liu, Xiao
    ANALYST, 2011, 136 (21) : 4563 - 4569
  • [9] Electrochemical sensor for epinephrine based on a glassy carbon electrode modified with graphene/gold nanocomposites
    Cui, Fei
    Zhang, Xiaoli
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 669 : 35 - 41
  • [10] A Sensitive Chlorpromazine Voltammetric Sensor Based on Graphene Oxide Modified Glassy Carbon Electrode
    Tajik, Somayeh
    Beitollahi, Hadi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2019, 6 (01): : 171 - 182