Comparative Study of Reference Current Generation for Shunt Active Power Filter

被引:0
作者
Panchbhai, Anand [1 ]
Prajapati, Nikunj [2 ]
Parmar, Shreya [3 ]
机构
[1] Enggenius Classes, Vadodara, India
[2] GEC, Elect Dept, Bharuch, India
[3] SVIT, Elect Dept, Vasad, India
来源
2017 INTERNATIONAL CONFERENCE ON POWER AND EMBEDDED DRIVE CONTROL (ICPEDC) | 2017年
关键词
Power Quality; Total Harmonic Distortion; Shunt Active Power Filter; Synchronous Reference Frame; PQ theory;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Presently, nonlinearity of Electrical utility leads to poor power quality due to increasing use of PE converters which results in financial loss, environmental impacts or safety concerns. It has many significant causes of poor power quality i.e., Harmonic pollution, Load imbalances resulting in voltage imbalance, Reactive power. As a consequence, Betterment of power Quality is on demand with the help of different kind of filters. Historically, passive filters have been proposed to mitigate harmonic pollution but nowadays the best filtering performance is obtained with an active filter using a closed loop control system. In this paper, shunt active power filter is used with two prominent theories for harmonic conditioning. 1) Instantaneous Active and reactive power theory IPQI and 2) synchronous reference frame theory [DQ]. Comparative analysis is done for different parameters like reactive power, Total Harmonic Distortion (THD), and power factor. Dynamic response is also observed. All the simulations arc done in MATLAB/Simulink.
引用
收藏
页码:381 / 386
页数:6
相关论文
共 50 条
[31]   Shunt active power filter model predictive current control [J].
Jiang, Suxia ;
Chen, Hao ;
Jin, Nan ;
Cui, Guangzhao ;
Zhang, Yang ;
Tao, Tao .
ENERGY SCIENCE AND APPLIED TECHNOLOGY (ESAT 2016), 2016, :311-315
[32]   Shunt active power filter with dynamic output current limitation [J].
Pregitzer, R. ;
Pinto, J. G. ;
Monteiro, Luis F. C. ;
Afonso, Joao L. .
2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, :1021-1026
[33]   Improved Current Control Strategy for Shunt Active Power Filter [J].
Susluoglu, Berrin ;
Karsli, Vedat M. .
2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, :1379-1382
[34]   Recurrent Wavelet Fuzzy Neural Network-Based Reference Compensation Current Control Strategy for Shunt Active Power Filter [J].
Chen, Cheng-, I ;
Chen, Yeong-Chin ;
Chen, Chung-Hsien .
ENERGIES, 2022, 15 (22)
[35]   Evaluation of a Shunt Active Power Filter with Energy Backup Capability [J].
Exposto, Bruno ;
Pinto, J. G. ;
Goncalves, Henrique ;
Monteiro, Vitor ;
Pedrosa, Delfim ;
Couto, Carlos ;
Afonso, Joao L. .
39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, :5963-5968
[36]   Study of Control Strategies for Shunt Active Power Filter for Harmonics Suppression [J].
Puchalapalli, Sambasivaiah ;
Pindoriya, Naran M. .
2017 7TH INTERNATIONAL CONFERENCE ON POWER SYSTEMS (ICPS), 2017, :218-223
[37]   Indirect current controlled shunt active power filter for power quality improvement [J].
Mahanty, R. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 62 :441-449
[38]   Comparative Analysis on Current Control Methods of Shunt Active Power Filter for the Improvement of Grid Energy Quality [J].
Imad, Aboudrar ;
El Hani, Soumia ;
Mediouni, Hamza ;
Echchaachouai, Amina .
PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON ELECTRICAL AND INFORMATION TECHNOLOGIES (ICEIT 2017), 2017,
[39]   Model Predictive Current Control for Low-Cost Shunt Active Power Filter [J].
Abdel-Aziz, Ali A. ;
Elgenedy, Mohamed A. ;
Williams, Barry W. .
CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2024, 10 (04) :1589-1598
[40]   Delay loop current control methods of Shunt Active Power Filter [J].
Liu, Gui-ying ;
Su, Shi-ping .
MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION IV, PTS 1 AND 2, 2012, 128-129 :105-108