Histologic Evaluation of Human Posterior Lamellar Discs for Femtosecond Laser Descemet's Stripping Endothelial Keratoplasty

被引:34
作者
Cheng, Yanny Y. Y. [1 ]
Kang, Shin J. [2 ]
Grossniklaus, Hans E. [2 ]
Pels, Elisabeth [3 ]
Duimel, Hans J. Q. [4 ]
Frederik, Peter M. [4 ]
Hendrikse, Fred [1 ]
Nuijts, Rudy M. M. A. [1 ]
机构
[1] Univ Hosp Maastricht, Dept Ophthalmol, NL-6202 AZ Maastricht, Netherlands
[2] Emory Univ, Sch Med, Dept Ophthalmol, Emory Eye Ctr, Atlanta, GA 30322 USA
[3] Netherlands Inst Neurosci, Cornea Bank Amsterdam, Amsterdam, Netherlands
[4] Maastricht Univ, Fac Med, Electron Microscopy Unit, Maastricht, Netherlands
关键词
femtosecond laser; Descemet's stripping endothelial keratoplasty; posterior lamellar disc; organ culture; histology; electron microscopy; IN-SITU KERATOMILEUSIS; ANTERIOR-CHAMBER SYSTEM; VIVO CONFOCAL MICROSCOPY; PENETRATING KERATOPLASTY; PHOTOREFRACTIVE KERATECTOMY; SURGICAL TECHNIQUE; LABORATORY MODEL; CORNEAL RESPONSE; MICROKERATOME; FLAP;
D O I
10.1097/ICO.0b013e318183a379
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the histologic changes in corneal structure after femtosecond laser preparation of posterior lamellar discs more specifically, the smoothness of the stromal bed and the accuracy:of the predicted depth of the horizontal lamellar cut. Materials and methods: Nineteen human donor eyes unsuitable for transplantation were used. Femtosecond laser was used to prepare a horizontal lamellar cut in donor corneas at a depth of 400 mu m. Transmission electron microscopy images Were used to evaluate the changes in the corneal structure and to measure the damage zone. Scanning electron microscopy images were used to determine the relative depth of the horizontal lamellar Cut, and the stromal bed was examined to determine the smoothness of the Surface. Results: Transmission electron microscopy images showed a mean. damage zone of 6.8 +/- 3.1 mu m, which consisted of irregularly oriented collagen fibrils and electron-dense granular material. The collagen lamellac, both anteriorly and posteriorly of the damaged zone, showed a regular parallel configuration. The relative depth of the horizontal lamellar Cut as percentage of the total corneal thickness in the center and periphery was 70.4% +/- 4.5% and 55.6% +/- 5.9%. Scanning electron microscopy images of the stromal bed showed a relatively smooth surface. Conclusion: The femtosecond laser is effective to prepare a deep horizontal lamellar cut in a standardized method. The stromal bed is smooth and Without extensive adjacent tissue damage. The is thinner in the center and thicker at the edges, which may produce a mild hyperopic shift after femtosecond laser-assisted Descemet's stripping endothelial keratoplasty.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 46 条
[1]   Precision and accuracy of an artificial anterior chamber system in obtaining corneal lenticules for lamellar keratoplasty [J].
Behrens, A ;
Dolorico, AMT ;
Kara, DT ;
Novick, LH ;
McDonnell, PJ ;
Chao, LC ;
Wellik, SR ;
Chuck, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (10) :1679-1687
[2]   The use of the femtosecond laser in penetrating keratoplasty [J].
Buratto, Lucio ;
Bohm, Elisabetta .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (05) :737-742
[3]   Corneal endothelial viability after femtosecond laser preparation of posterior lamellar discs for Descemet-stripping endothelial keratoplasty [J].
Cheng, Yanny Y. Y. ;
Pels, Elisabeth ;
Cleutjens, Jack P. M. ;
van Suylen, Robert J. ;
Hendrikse, Fred ;
Nuijts, Rudy M. M. A. .
CORNEA, 2007, 26 (09) :1118-1122
[4]   Femtosecond-laser-assisted Descemet's stripping endothelial keratoplasty [J].
Cheng, Yanny Y. Y. ;
Pels, Elisabeth ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (01) :152-155
[5]  
Durrie DS, 2004, J REFRACT SURG, V20, pS614
[6]   Intacs insertion with the femtosecond laser for the management of keratoconus - One-year results [J].
Ertan, Aylin ;
Kamburoglu, Gunhal ;
Bahadir, Mehmet .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12) :2039-2042
[7]   Results of penetrating keratoplasty performed with a femtosecond laser zigzag incision initial report [J].
Farid, Marjan ;
Kim, Matthew ;
Steinert, Roger F. .
OPHTHALMOLOGY, 2007, 114 (12) :2208-2212
[8]   Femtosecond-laser arcuate wedge-shaped resection to correct high residual astigmatism after penetrating keratoplasty [J].
Ghanem, Ramon C. ;
Azar, Dimitri T. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (09) :1415-1419
[9]   Histologic and ultrastructural findings in a case of traumatic graft failure in deep lamellar endothelial keratoplasty - A clinicopathologic case report [J].
Gooi, Patrick ;
Robinson, Jennifer W. ;
Brownstein, Seymour ;
Rocha, Guillermo .
CORNEA, 2007, 26 (07) :853-857
[10]   Descemet-stripping automated endothelial keratoplasty [J].
Gorovoy, Mark S. .
CORNEA, 2006, 25 (08) :886-889