Task-specific enhancement filters in storage phosphor images from the Vistascan system for detection of proximal caries lesions of known size

被引:32
作者
Haiter-Neto, Francisco [1 ]
Casanova, Marcia Spinelli [1 ]
Frydenberg, Morten [2 ]
Wenzel, Ann [3 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, BR-13414901 Piracicaba, SP, Brazil
[2] Univ Aarhus, Fac Hlth Sci, Dept Biostat, Aarhus, Denmark
[3] Univ Aarhus, Sch Dent, Dept Oral Radiol, Aarhus, Denmark
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2009年 / 107卷 / 01期
关键词
APPROXIMAL CARIES; DIGITAL RADIOGRAPHY; DOMAIN TECHNIQUES; DIAGNOSIS; DEPTH; FILM; ACCURACY; STANDARD; QUALITY;
D O I
10.1016/j.tripleo.2008.09.031
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The aim was to compare original 8-bit images from the Vistascan storage phosphor plate system with images enhanced with specific filters for detection of proximal caries lesions and, further, to analyze the mutual sensitivity of the filtered images for different lesion sizes. Study design. One hundred sixty approximal noncavitated surfaces were radiographed using the Vistascan storage phosphor plate system. Original and enhanced (Fine, Caries1, and Caries2 filters) images were assessed by 6 observers who recorded the presence/absence of proximal carious lesions. Microscopy served to detect and measure true lesion size. Results. One hundred one surfaces were sound, and 59 had lesions. The sensitivity of the Fine filter images was significantly higher than the Caries1 and Caries2 filter modalities (P < .005). The original images did not differ significantly from the Caries1 and Caries2 modalities. Both the Fine filter and the original images had a significantly higher specificity than the Caries2 modality (P < .005). The overall accuracies for the Fine filter and the original images were significantly higher than for the Caries2 modality (P < .005). The Fine filter images also had higher accuracy than the Caries1 modality (P < .05). The mutual sensitivity of the filters varied little with lesion size. Conclusion. Fine filter may be a promising enhancement tool for images used for detection of shallow carious lesion, because it showed less observer variability. The task-specific enhancement filters, Caries1 and Caries2, were less accurate than the original and Fine filter images and cannot be recommended for detection of the lesion sizes included in this study. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: 116-121)
引用
收藏
页码:116 / 121
页数:6
相关论文
共 18 条
  • [1] Accuracy of proximal caries depth measurements:: Comparison between limited cone beam computed tomography, storage phosphor and film radiography
    Akdeniz, B. Guniz
    Grondahl, Hans-Goran
    Magnusson, Bengt
    [J]. CARIES RESEARCH, 2006, 40 (03) : 202 - 207
  • [2] Radiographic digital image enhancement. Part II: transform domain techniques
    Analoui, M
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (02) : 65 - 77
  • [3] Radiographic image enhancement. Part I: spatial domain techniques
    Analoui, M
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (01) : 1 - 9
  • [4] In vitro comparison of conventional film and direct digital imaging in the detection of approximal caries
    Castro, V. M.
    Katz, J. O.
    Hardman, P. K.
    Glaros, A. G.
    Spencer, P.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (03) : 138 - 142
  • [5] Digital radiography of interproximal caries: Effect of different filters
    Eickholz, P
    Kolb, I
    Lenhard, M
    Hassfeld, S
    Staehle, HJ
    [J]. CARIES RESEARCH, 1999, 33 (03) : 234 - 241
  • [6] Grey-scale reversed radiographic display in the detection of approximal caries
    Haak, R
    Wicht, MJ
    [J]. JOURNAL OF DENTISTRY, 2005, 33 (01) : 65 - 71
  • [7] Koob A, 2004, AM J DENT, V17, P388
  • [8] Accuracy of diagnosing occlusal caries using enhanced digital images
    Kositbowornchai, S
    Basiw, M
    Promwang, Y
    Moragorn, H
    Sooksuntisakoonchai, N
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (04) : 236 - 240
  • [9] Image processing and enhancement provided by commercial dental software programs
    Lehmann, TM
    Troeltsch, E
    Spitzer, K
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (04) : 264 - 272
  • [10] Detection of proximal caries in vitro using standard and task-specific enhanced images from a storage phosphor plate system
    Li, G.
    Sanderink, G. C. H.
    Berkhout, W. E. R.
    Syriopoulos, K.
    van der Stelt, P. F.
    [J]. CARIES RESEARCH, 2007, 41 (03) : 231 - 234