A continuous loading apparatus for measuring three-dimensional stiffness of ankle-foot orthoses

被引:18
作者
Cappa, P
Patanè, F
Di Rosa, G
机构
[1] Univ Roma La Sapienza, Dept Mech & Aeronaut, Rome, Italy
[2] Childrens Hosp Bambino Gesu, Paediat Neurorehabil Div, Rome, Italy
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2005年 / 127卷 / 06期
关键词
D O I
10.1115/1.2049313
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper describes a novel device to evaluate the mechanical properties of ankle foot orthoses (AFOs). The apparatus permits the application to AFOs of continuous three-dimensional (3D) movements between specified and settable endpoints. Using all x-v robot with a rotary stage and a six-component load cell, characteristic displacement versus reaction force curves can be generoted and consequently the ankle moments can be determined as a function of dorsi/plantar flexion, inv/eversion and int/external rotation. Representative curves for two polypropylene lateral leaf AFOs, different in shape but produced for the same leg by a skilled orthotist, are presented to illustrate the capabilities of the novel testing system. The metrological investigation showed that the apparatus creates a highly repeatable data set (uncertainty <= 1% FSO).
引用
收藏
页码:1025 / 1029
页数:5
相关论文
共 22 条
[11]  
LEHMANN JF, 1987, ARCH PHYS MED REHAB, V68, P763
[12]  
Leone D., 1988, Proceedings of the Fourteenth Annual Northeast Bioengineering Conference (IEEE Cat. No.88-CH2666-6), P26, DOI 10.1109/NEBC.1988.19334
[13]   A STRUCTURAL MODEL FOR MOLDED THERMOPLASTIC ANKLE-FOOT ORTHOSES [J].
LEONE, DJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1987, 109 (04) :305-310
[14]  
Lunsford T., 1994, J PROSTHET ORTHOT, V6, P3, DOI DOI 10.1097/00008526-199400610-00002
[15]   NEW FLEXIBLE DESIGN OF DROP-FOOT ORTHOSIS [J].
MOLLAN, RAB ;
JAMES, WV .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1977, 8 (04) :310-314
[16]   Shoehorn-type ankle-foot orthoses: Prediction of flexibility [J].
Nagaya, M .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (01) :82-84
[17]  
*NIST, NIST STAT ENG HDB TY
[18]  
Robert singerman., 1999, J PROSTHET ORTHOT, V11, P48
[19]   Comparison of a dynamic and a hinged ankle-foot orthosis by gait analysis in patients with hemiplegic cerebral palsy [J].
Romkes, J ;
Brunner, R .
GAIT & POSTURE, 2002, 15 (01) :18-24
[20]   A method for the measurement of three-dimensional geometry of casts used for the manufacture of ankle foot orthoses [J].
Sykes, N ;
Peacock, JC ;
Johnson, GR .
CLINICAL BIOMECHANICS, 1998, 13 (07) :542-547