Validation of some procedures for quantifying platinum at sub-μg/L level in some real matrices by catalytic adsorptive stripping voltammetry

被引:9
作者
Desimoni, E [1 ]
Brunetti, B [1 ]
Cattaneo, R [1 ]
机构
[1] Univ Milan, I-20133 Milan, Italy
关键词
catalytic adsorptive stripping voltammetry; platinum; sub-mu g/L level; tap water; beer; lettuce;
D O I
10.1002/elan.200402845
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The potential toxicological properties of platinum group elements, usually present in real matrices at sub-ng/g level, explain the increasing interest in developing specific and sensitive analytical methods. In this work, a validation study was performed in order to ensure the fitness-for-purposes of procedures developed for quantifying platinum in tap water, beer and lettuce using an extremely sensitive method based on catalytic adsorptive stripping voltammetry. The work involved the estimation of selectivity, detection and quantitation limits, range, accuracy (trueness plus precision), uncertainty of measurement (UOM), robustness and recovery. The results are discussed in the light of the most recent literature findings.
引用
收藏
页码:304 / 310
页数:7
相关论文
共 47 条
[1]  
Akatsuka K, 2000, ANTHROPOGENIC PLATINUM-GROUP ELEMENT EMISSIONS, P123
[2]   A contribution to the ecology and enology of platinum [J].
Alt, F ;
Eschnauer, HR ;
Mergler, B ;
Messerschmidt, J ;
Tolg, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (08) :1013-1019
[3]  
[Anonymous], METROHM APPL B
[4]  
Artelt S, 2000, ANTHROPOGENIC PLATINUM-GROUP ELEMENT EMISSIONS, P217
[5]   Recent advances in the determination of the platinum group elements and gold [J].
Barefoot, RR ;
Van Loon, JC .
TALANTA, 1999, 49 (01) :1-14
[6]  
BEGEROV EJ, 1999, ANTROPOGENIC PLATINU, P227
[7]   Determination of physiological noble metals in human urine using liquid-liquid extraction and Zeeman electrothermal atomic absorption spectrometry [J].
Begerow, J ;
Turfeld, M ;
Dunemann, L .
ANALYTICA CHIMICA ACTA, 1997, 340 (1-3) :277-283
[8]   A program for the weighted linear least-squares regression of unbalanced response arrays [J].
Desimoni, E .
ANALYST, 1999, 124 (08) :1191-1196
[9]   Validation of a procedure for quantifying platinum at sub-μg/L level in matrices of alimentary and environmental concern by catalytic adsorptive stripping voltammetry [J].
Desimoni, E ;
Brunetti, B ;
Cattaneo, R .
JOURNAL DE PHYSIQUE IV, 2003, 107 :373-375
[10]  
Desimoni E, 2002, ELECTROANAL, V14, P459, DOI 10.1002/1521-4109(200203)14:6<459::AID-ELAN459>3.3.CO