摘要
Background. Video-assisted thoracic surgery offers a minimally invasive method for diagnosing and treating small pulmonary lesions, although the localization of these lesions is sometimes problematic. Various localization methods have been reported but few studies have described their efficacy and adverse events. Methods. We performed computed tomography (CT)-guided localization using a hook wire in 417 patients with 500 lesions treated between January 2006 and December 2010. Results. We located 178 lesions with a ground-glass opacity component and 322 solid lesions. The solid lesions had smaller tumor diameters and were located further from the pleura. Tumor depth to size ratio was 0.9 +/- 0.9 for the lesions with a ground-glass opacity component and 1.8 +/- 1.5 for the solid lesions (p < 0.001). Pneumothorax requiring aspiration was observed in 4.6% patients, and hemoptysis and pulmonary hematoma was observed in 10.3%. Systemic air embolism with no sequelae and spontaneous resolution occurred in a patient (0.24%). The morbidity rate was 15.1%. Male patients, patients who had undergone multiple localization, and heavy smokers were at a higher risk of pneumothorax requiring aspiration. Insertion distance more than 25 mm was a risk factor for hemoptysis and pulmonary hematoma (p < 0.001). Procedure duration per lesion was 14 +/- 5 minutes. Dislodgement occurred in 2 patients (0.4%). Conclusions. The safety, reliability, and convenience of CT-guided hook wire localization are acceptable. Localization for lesions with a ground-glass opacity component may be performed when the lesions are relatively large and shallow. Insertion distances greater than 25 mm are associated with a risk of pulmonary hematoma and hemoptysis. (C) 2013 by The Society of Thoracic Surgeons
引用
收藏
页码:1203 / 1208
页数:6
相关论文
共 30 条
[1]   Computed Tomography-Guided Preoperative Radiotracer Localization of Nonpalpable Lung Nodules [J].
Bellomi, Massimo ;
Veronesi, Giulia ;
Trifiro, Giuseppe ;
Brambilla, Sarah ;
Bonello, Luke ;
Preda, Lorenzo ;
Casiraghi, Monica ;
Borri, Alessandro ;
Paganelli, Giovanni ;
Spaggiari, Lorenzo .
ANNALS OF THORACIC SURGERY, 2010, 90 (06) :1759-1765
[2]   Not palpable? Role of radio-guided video-assisted thoracic surgery for nonpalpable solitary pulmonary nodules [J].
Bertolaccini L. ;
Terzi A. ;
Spada E. ;
Acchiardi F. ;
Ghirardo D. .
General Thoracic and Cardiovascular Surgery, 2012, 60 (5) :280-284
[3]   A pilot study of the role of TC-99 radionuclide in localization of pulmonary nodular lesions for thoracoscopic resection [J].
Chella, A ;
Lucchi, M ;
Ambrogi, MC ;
Menconi, G ;
Melfi, FMA ;
Gonfiotti, A ;
Boni, G ;
Angeletti, CA .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 18 (01) :17-21
[4]   Video-assisted thoracoscopic surgery for pulmonary nodules: rationale for preoperative computed tomography-guided hookwire localization [J].
Ciriaco, P ;
Negri, G ;
Puglisi, A ;
Nicoletti, R ;
Del Maschio, A ;
Zannini, P .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (03) :429-433
[5]   Preoperative localization of small pulmonary lesions with a short hook wire and suture system: Experience with 168 procedures [J].
Dendo, S ;
Kanazawa, S ;
Ando, A ;
Hyodo, T ;
Kouno, Y ;
Yasui, K ;
Mimura, H ;
Akaki, S ;
Kuroda, M ;
Shimizu, N ;
Hiraki, Y .
RADIOLOGY, 2002, 225 (02) :511-518
[6]   CT fluoroscopy-guided bronchoscopic dye marking for resection of small peripheral pulmonary nodules [J].
Endo, M ;
Kotani, Y ;
Satouchi, M ;
Takada, Y ;
Sakamoto, T ;
Tsubota, N ;
Furukawa, R .
CHEST, 2004, 125 (05) :1747-1752
[7]   Systemic air embolism during percutaneous core needle biopsy of the lung: frequency and risk factors [J].
Freund, Martin C. ;
Petersen, Johannes ;
Goder, Katharina C. ;
Bunse, Tillmann ;
Wiedermann, Franz ;
Glodny, Bernhard .
BMC PULMONARY MEDICINE, 2012, 12
[8]   Sonographic guidance for the localization of peripheral pulmonary nodules during thoracoscopy [J].
Greenfield, AL ;
Steiner, RM ;
Liu, JB ;
Cohn, HE ;
Goldberg, BB ;
Rawool, NM ;
Merton, DA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (04) :1057-1060
[9]   Nonfatal systemic air embolism complicating percutaneous CT-guided transthoracic needle biopsy - Four cases from a single institution [J].
Hiraki, Takao ;
Fujiwara, Hiroyasu ;
Sakurai, Jun ;
Iguchi, Toshihiro ;
Gobara, Hideo ;
Tajirl, Nobuhisa ;
Mimura, Hidefumi ;
Kanazawa, Susumu .
CHEST, 2007, 132 (02) :684-690
[10]   Air Embolism and Needle Track Implantation Complicating CT-Guided Percutaneous Thoracic Biopsy: Single-Institution Experience [J].
Ibukuro, Kenji ;
Tanaka, Rei ;
Takeguchi, Takaya ;
Fukuda, Hozumi ;
Abe, Shoko ;
Tobe, Kimiko .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (05) :W430-W436