Short-term glucagon stimulation test of C-peptide effect on glucose utilization in patients with type 1 diabetes mellitus

被引:4
作者
Mojto, Viliam [1 ]
Rausova, Zuzana [2 ]
Chrenova, Jana [2 ]
Dedik, Ladislav [2 ]
机构
[1] Comenius Univ, Fac Med, Clin Internal Med 3, Limbova 5, Bratislava 83305, Slovakia
[2] Slovak Univ Technol Bratislava, Fac Mech Engn, Inst Automat Measurement & Appl Informat, Namestie Slobody 17, Bratislava 81231, Slovakia
关键词
C-peptide; Glucagon stimulation test; Glucose utilization; Pharmacodynamics; Pharmacokinetics; INSULIN-SECRETION RATES; TOLERANCE TEST;
D O I
10.1007/s11517-015-1416-2
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This work aimed to evaluate the use of a four-point glucagon stimulation test of C-peptide effect on glucose utilization in type 1 diabetic patients using a new mathematical model. A group of 32 type 1 diabetic patients and a group of 10 healthy control subjects underwent a four-point glucagon stimulation test with blood sampling at 0, 6, 15 and 30 min after 1 mg glucagon bolus intravenous administration. Pharmacokinetic and pharmacokinetic/pharmacodynamic models of C-peptide effect on glucose utilization versus area under curve (AUC) were used. A two-sample t test and ANOVA with Bonferroni correction were used to test the significance of differences between parameters. A significant difference between control and patient groups regarding the coefficient of whole-body glucose utilization and AUC C-peptide/AUC glucose ratio (p a parts per thousand(a) 0.001 and p = 0.002, respectively) was observed. The high correlation (r = 0.97) between modeled coefficient of whole-body glucose utilization and numerically calculated AUC C-peptide/AUC glucose ratio related to entire cohort indicated the stability of used method. The short-term four-point glucagon stimulation test allows the numerically calculated AUC C-peptide/AUC glucose ratio and/or the coefficient of whole-body glucose utilization calculated from model to be used to diagnostically identify type 1 diabetic patients.
引用
收藏
页码:1361 / 1369
页数:9
相关论文
共 23 条
  • [1] AHREN B, 1987, ACTA MED SCAND, V221, P185
  • [2] Akaike H., 1976, SYSTEM IDENTIFICATIO, V126, P27, DOI DOI 10.1016/S0076-5392(08)60869-3
  • [3] A numerical deconvolution method to estimate C-peptide secretion in humans after an intravenous glucose tolerance test
    Boston, Ray C.
    Pei, Dee
    Moate, Peter J.
    [J]. METABOLISM-CLINICAL AND EXPERIMENTAL, 2009, 58 (07): : 891 - 900
  • [4] Brown RJ, 2007, DIABETES, V56, pA54
  • [5] Dynamics of insulin action in hypertension: assessment from minimal model interpretation of intravenous glucose tolerance test data
    Burattini, Roberto
    Morettini, Micaela
    Di Nardo, Francesco
    Boemi, Massimo
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2011, 49 (07) : 831 - 841
  • [6] CLAUSS A., 1957, ACTA HAEMATOL, V17, P237
  • [7] Dedik L., 1999, SYSTEM APPROACH TECH
  • [8] DEFRONZO RA, 1979, AM J PHYSIOL, V237, pE214
  • [9] Characterisation of the iterative integral parameter identification method
    Docherty, Paul D.
    Chase, J. Geoffrey
    David, Timothy
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (02) : 127 - 134
  • [10] New mathematical methods in pharmacokinetic modeling
    Durisová, M
    Dedík, L
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2005, 96 (05) : 335 - 342