Characteristics and Electrical Properties of Epoxy Resin Surface Layers Fluorinated at Different Temperatures

被引:34
作者
Liu, Yaqiang [1 ,2 ]
An, Zhenlian [1 ]
Yin, Qianqian [2 ]
Zheng, Feihu [1 ]
Lei, Qingquan [3 ]
Zhang, Yewen [1 ]
机构
[1] Tongji Univ, Dept Elect Engn, Shanghai 201804, Peoples R China
[2] Tongji Univ, Sch Phys Sci & Engn, Shanghai 200092, Peoples R China
[3] Harbin Univ Sci & Technol, Sch Elect & Elect Engn, Harbin 150040, Peoples R China
基金
中国国家自然科学基金;
关键词
Epoxy resin insulator; surface fluorination; fluorination temperature; surface properties; surface charge accumulation; CHARGE ACCUMULATION; FUNDAMENTAL RESEARCH; POLYMERIC MATERIALS; INSULATORS; PARTICLE; SF6; SPACERS; BREAKDOWN;
D O I
10.1109/TDEI.2013.6633718
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Epoxy resin sheets were surface fluorinated in a laboratory vessel using a F-2/N-2 mixture with 12.5% F-2 by volume at the different temperatures of 25, 55, 75, and 95 degrees C for the same time of 30 min, to investigate the effect of fluorination temperature on surface electrical properties. ATR-IR analyses indicate that fluorination led to substantial changes in surface chemical composition and structure, depending on fluorination temperature, and SEM surface and cross section images show an evolution of surface morphology and an increase of thickness of the fluorinated layer with fluorination temperature. Conductivity measurements reveal that the surface fluorinated samples have higher surface conductivities than the unfluorinated sample, and surface conductivity significantly increases with fluorination temperature. Surface potential measurements, performed about 10 s after corona charging, indicate lower initial surface potentials for the surface fluorinated samples than the unfluorinated sample, and a decrease of the initial surface potential with surface conductivity. The initial surface potential was found to decrease dramatically above a critical surface conductivity (3.0 x 10(-14) S), and almost to zero when surface conductivity increased to 10(-12) S. Contact angle measurements and surface energy calculations show a much higher surface polarity of the surface fluorinated samples compared to the unfluorinated sample and a dramatic increase of the surface polarity with fluorination temperature. An increase in degree of chain scission is considered to be the main cause for the increases of surface conductivity and surface polarity with fluorination temperature.
引用
收藏
页码:1859 / 1868
页数:10
相关论文
共 38 条
[1]   Correlation between space charge accumulation in polyethylene and its fluorinated surface layer characteristics [J].
An, Zhenlian ;
Liu, Chenxia ;
Chen, Xuan ;
Zheng, Feihu ;
Zhang, Yewen .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2012, 45 (03)
[2]   Surface selective modification of poly(vinyl chloride) film with lithiated alpha,omega-diaminopoly(alkene oxide)s [J].
Bergbreiter, DE ;
Xu, GF .
POLYMER, 1996, 37 (12) :2345-2352
[3]   Bond dissociation energies of organic molecules [J].
Blanksby, SJ ;
Ellison, GB .
ACCOUNTS OF CHEMICAL RESEARCH, 2003, 36 (04) :255-263
[4]   Study of crosslinking acid copolymer/DGEBA systems by FTIR [J].
Cherdoud-Chihani, A ;
Mouzali, M ;
Abadie, MJM .
JOURNAL OF APPLIED POLYMER SCIENCE, 2003, 87 (13) :2033-2051
[5]   Modeling of Epoxy Resin Spacers for the 1 MV DC Gas Insulated Line of ITER Neutral Beam Injector System [J].
De Lorenzi, A. ;
Grando, L. ;
Pesce, A. ;
Bettini, P. ;
Specogna, R. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (01) :77-87
[6]   EFFECT OF SURFACE-CHARGE ON IMPULSE FLASHOVER OF INSULATORS IN SF6 [J].
FARISH, O ;
ALBAWY, I .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1991, 26 (03) :443-452
[7]   MECHANISM AND EFFECT OF DC CHARGE ACCUMULATION ON SF6 GAS INSULATED SPACERS [J].
FUJINAMI, H ;
TAKUMA, T ;
YASHIMA, M ;
KAWAMOTO, T .
IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (03) :1765-1772
[8]   Cross-equipment study on charging phenomena of solid insulators in high voltage equipment [J].
Hama, H. ;
Hikosaka, T. ;
Okabe, S. ;
Okubo, H. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (02) :508-519
[9]   Development of insulation structure and enhancement of insulation reliability of 500 kV dc GIS [J].
Hasegawa, T ;
Yamaji, K ;
Hatano, M ;
Endo, F ;
Rokunohe, T ;
Yamagiwa, T .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (01) :194-202
[10]  