COST-EFFECTIVE TECHNOLOGIES TO CONTROL INDOOR AIR QUALITY AND COMFORT IN ENERGY EFFICIENT BUILDING RETROFITTING

被引:0
作者
Revel, Gian Marco [1 ]
Arnesano, Marco [1 ]
Pietroni, Filippo [1 ]
Frick, Juergen [2 ]
Reichert, Manuela [2 ]
Schmitt, Katrin [3 ]
Huber, Jochen [3 ]
Ebermann, Martin [4 ]
Battista, Umberto [5 ]
Alessi, Franck [6 ]
机构
[1] Univ Politecn Marche, Dept Ind Engn & Math Sci, Ancona, Italy
[2] Univ Stuttgart, Mat Testing Inst Stuttgart, Stuttgart, Germany
[3] Fraunhofer Inst Phys Measurement Tech, Freiburg, Germany
[4] InfraTec GmbH, Dresden, Germany
[5] Stam Srl, Genoa, Italy
[6] CEA, INES, Lab Energet Batiment, Le Bourget Du Lac, France
来源
ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL | 2015年 / 14卷 / 07期
关键词
energy efficiency; gas sensor; HVAC control; indoor air quality; thermal comfort; ENVIRONMENTS; RISK;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents a toolset for the efficient control of the indoor air quality and thermal comfort in retrofitted buildings. The refurbishment of existing buildings, compliant to actual regulations, often leads to airtightness and the consequent poor conditions for the occupants that could cause low productivity and even sickness. For this reason, the CETIEB (Cost Effective Tools for Better Indoor Environment in Retrofitted Energy Efficient Buildings) project developed innovative low-cost solutions to monitor and control the indoor air quality and thermal comfort. Among the technologies developed, this paper presents ad-hoc sensors for the monitoring of Total Volatile Organic Components (TVOC), CO2 and thermal comfort together with a control logic that, using measured data, provides the optimal rules to actuate the control devices (ventilation, heating/cooling, windows opening, shutters operation and so on). The application and validation of the integrated solution, monitoring plus control logic, was performed in a laboratory building to compare the performance of the proposed solution with the traditional system employed in buildings. The results turned out to show sensors performances comparable with commercial solutions but with a significant reduction of costs. Moreover, the application of the integrated solution showed an improvement of the indoor air quality and comfort with a 15% of energy saving, compared to the traditional thermostatic control.
引用
收藏
页码:1487 / 1494
页数:8
相关论文
共 18 条
[1]  
[Anonymous], 1996, INDOOR AIR
[2]  
Capolongo S, 2013, ENVIRON ENG MANA S11, V12, P209
[3]  
European Commission, 2009, LOW EN BUILD EUR CUR
[4]  
European Commission, 2011, PROM ACT HLTH IND AI
[5]  
Giusca R, 2009, ENVIRON ENG MANAG J, V8, P1495
[6]  
Grindvoll H, 2012, J INF TECHNOL CONSTR, V17, P43
[7]   REAL NEEDS AND PREVENTIVE STRATEGIES FOR MAINTAINING SUSTAINABLE QUALITY OF LIFE IN ENVIRONMENTS WITH AIR CONDITIONING [J].
Ioan, Carmen Catalina ;
Ursu, Cornelia .
ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2012, 11 (04) :879-884
[8]  
Kalmár T, 2011, ENVIRON ENG MANAG J, V10, P1249
[9]   Indoor residential chemical emissions as risk factors for-respiratory and allergic effects in children: a review [J].
Mendell, M. J. .
INDOOR AIR, 2007, 17 (04) :259-277
[10]   A review on buildings energy consumption information [J].
Perez-Lombard, Luis ;
Ortiz, Jose ;
Pout, Christine .
ENERGY AND BUILDINGS, 2008, 40 (03) :394-398