Quantitative mouse renal perfusion using arterial spin labeling

被引:25
作者
Rajendran, Reshmi [1 ]
Lew, Si Kang [1 ]
Yong, Cai Xian [1 ]
Tan, Jolena [1 ]
Wang, Danny J. J. [2 ]
Chuang, Kai-Hsiang [1 ,3 ,4 ]
机构
[1] Agcy Sci Technol & Res, Singapore Bioimaging Consortium, Magnet Resonance Imaging Grp, Singapore, Singapore
[2] Univ Calif Los Angeles, Dept Neurol, Los Angeles, CA 90024 USA
[3] Natl Univ Singapore, Clin Imaging Res Ctr, Singapore 117548, Singapore
[4] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Physiol, Singapore 117548, Singapore
关键词
kidney perfusion; MRI; arterial spin labeling; flow-sensitive alternating inversion recovery (FAIR); carbogen; translational; INVERSION-RECOVERY FAIR; CEREBRAL-BLOOD-FLOW; RELAXATION-TIMES; KIDNEY PERFUSION; MR PERFUSION; RAT-KIDNEY; TESLA; QUANTIFICATION; OXYGEN; WATER;
D O I
10.1002/nbm.2939
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Information on renal perfusion is essential for the diagnosis and prognosis of kidney function. Quantification using gadolinium chelates is limited as a result of filtration through renal glomeruli and safety concerns in patients with kidney dysfunction. Arterial spin labeling MRI is a noninvasive technique for perfusion quantification that has been applied to humans and animals. However, because of the low sensitivity and vulnerability to motion and susceptibility artifacts, its application to mice has been challenging. In this article, mouse renal perfusion was studied using flow-sensitive alternating inversion recovery at 7 T. Good perfusion image quality was obtained with spin-echo echoplanar imaging after controlling for respiratory, susceptibility and fat artifacts by triggering, high-order shimming and water excitation, respectively. High perfusion was obtained in the renal cortex relative to the medulla, and signal was absent in scans carried out post mortem. Cortical perfusion increased from 397 +/- 36 (mean +/- standard deviation) to 476 +/- 73 mL/100 g/min after switching from 100% oxygen to carbogen with 95% oxygen and 5% carbon dioxide. The perfusion in the medulla was 2.5 times lower than that in the cortex and changed from 166 +/- 41 mL/100 g/min under oxygen to 203 +/- 40 mL/100 g/min under carbogen. T1 decreased in both the cortex (from 1570 +/- 164 to 1377 +/- 72 ms, p < 0.05) and medulla (from 1788 +/- 107 to 1573 +/- 144 ms, p < 0.05) under carbogen relative to 100% oxygen. The results showed the potential of the use of ASL for perfusion quantification in mice and in models of renal diseases. Copyright (C) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:1225 / 1232
页数:8
相关论文
共 53 条
[1]   Changes of renal blood flow after ESWL: Assessment by ASL MR imaging, contrast enhanced MR imaging, and renal resistive index [J].
Abd Ellah, Mohamed ;
Kremser, Christian ;
Pallwein, Leo ;
Aigner, Friedrich ;
Schocke, Michael ;
Peschel, Reinhard ;
Pedross, Florian ;
Pinggera, Germar-Michael ;
Wolf, Christian ;
Alsharkawy, Mostafa A. M. ;
Jaschke, Werner ;
Frauscher, Ferdinand .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (01) :124-128
[2]   Comparing Kidney Perfusion Using Noncontrast Arterial Spin Labeling MRI and Microsphere Methods in an Interventional Swine Model [J].
Artz, Nathan S. ;
Wentland, Andrew L. ;
Sadowski, Elizabeth A. ;
Djamali, Arjang ;
Grist, Thomas M. ;
Seo, Songwon ;
Fain, Sean B. .
INVESTIGATIVE RADIOLOGY, 2011, 46 (02) :124-131
[3]  
Berr SS, 1999, J MAGN RESON IMAGING, V10, P886, DOI 10.1002/(SICI)1522-2586(199911)10:5<886::AID-JMRI38>3.0.CO
[4]  
2-P
[5]   High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media [J].
Boss, A ;
Martirosian, P ;
Graf, H ;
Claussen, CD ;
Schlemmer, HP ;
Schick, F .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (12) :1625-1630
[6]   FAIR-TrueFISP imaging of cerebral perfusion in areas of high magnetic susceptibility differences at 1.5 and 3 Tesla [J].
Boss, Andreas ;
Martirosian, Petros ;
Klose, Uwe ;
Naegele, Thomas ;
Claussen, Claus D. ;
Schick, Fritz .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (05) :924-931
[7]   Mouse Models of Diabetic Nephropathy [J].
Brosius, Frank C., III ;
Alpers, Charles E. ;
Bottinger, Erwin P. ;
Breyer, Matthew D. ;
Coffman, Thomas M. ;
Gurley, Susan B. ;
Harris, Raymond C. ;
Kakoki, Masao ;
Kretzler, Matthias ;
Leiter, Edward H. ;
Levi, Moshe ;
McIndoe, Richard A. ;
Sharma, Kumar ;
Smithies, Oliver ;
Susztak, Katalin ;
Takahashi, Nobuyuki ;
Takahashi, Takamune .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2009, 20 (12) :2503-2512
[8]  
Calamante F, 1996, NMR BIOMED, V9, P79, DOI 10.1002/(SICI)1099-1492(199604)9:2<79::AID-NBM399>3.0.CO
[9]  
2-4
[10]   Factors Affecting Occupational Exposure to Needlestick and Sharps Injuries among Dentists in Taiwan: A Nationwide Survey [J].
Cheng, Hsin-Chung ;
Su, Chen-Yi ;
Yen, Amy Ming-Fang ;
Huang, Chiung-Fang .
PLOS ONE, 2012, 7 (04)