Total body water measurement using bioelectrical impedance analysis, isotope dilution and total body potassium: a scoring system to facilitate intercomparison

被引:8
作者
Gonzalez, CH
Evans, JA
Smye, SW
Holland, P
机构
[1] Univ Caldas, Dept Phys, Manizales, Colombia
[2] Univ Leeds, Dept Med Phys, Leeds, W Yorkshire, England
[3] Univ Leeds, Dept Paediat, Leeds, W Yorkshire, England
关键词
bioelectrical impedance; dilution techniques; TBK; body water; scoring system;
D O I
10.1038/sj.ejcn.1601316
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objectives: (1) To develop a scale that is useful in evaluating the accuracy of multifrequency bioelectrical impedance analysis (MF-BIA) in the assessment of body water volumes against the accepted gold standard measurements based on isotope-dilution and total body potassium (TBK). (2) To perform a pilot test of the scale. Design: A scale was developed to evaluate the accuracy of MF-BIA in the assessment of body water volumes. Questions were obtained from reading the scientific literature and discussions involving the four authors. Three of these and two additional independent readers pre-tested the scale. A weighting was identified for each question and a pilot test with a sample of 10 articles (different to those used for the questionnaire performance) was conducted. A further validation was carried out with a second set of 20 articles and two additional independent readers. Results: The kappa statistic expressing the level of agreement between pairs of the first three authors using this scale with 10 articles, was 0.3, 0.4 and 0.6 after the first attempt. A second evaluation after specific changes improved the agreement to 0.8, 0.6 and 0.8. The mean score for 10 articles was 252 +/- 36 points from a total score of 400 (63 +/- 9%). The evaluation with the second set of 20 articles resulted in a kappa of 0.7 from two pairs of authors. The evaluation with two additional reviewers resulted in a kappa=0.7. Conclusion: A tool has been developed to assess the accuracy of the MF-BIA technique and to identify methodological components, plan future studies and critically evaluate data in this area. It is likely that this tool may also be used to assess the accuracy of single frequency studies. Sponsorship: COLCIENCIAS and University of Caldas, Colombia sponsor CH Gonzalez.
引用
收藏
页码:326 / 337
页数:12
相关论文
共 58 条
[21]   USE OF STATISTICAL-ANALYSIS IN THE NEW-ENGLAND JOURNAL OF MEDICINE [J].
EMERSON, JD ;
COLDITZ, GA .
NEW ENGLAND JOURNAL OF MEDICINE, 1983, 309 (12) :709-713
[22]   A SCORE SYSTEM FOR EVALUATING RANDOM CONTROL CLINICAL-TRIALS OF PROPHYLAXIS OF ABDOMINAL SURGICAL WOUND-INFECTION [J].
EVANS, M ;
POLLOCK, AV .
BRITISH JOURNAL OF SURGERY, 1985, 72 (04) :256-260
[23]   CALL FOR COMMENTS ON A PROPOSAL TO IMPROVE REPORTING OF CLINICAL-TRIALS IN THE BIOMEDICAL LITERATURE [J].
FACKLER, ML ;
HUTH, EJ ;
PITKIN, RM ;
RENNIE, D ;
BEGG, C ;
GREENLAND, S ;
OLKIN, I ;
STROUP, DF ;
DEEN, DF ;
LAU, J ;
DERISH, P ;
EASTWOOD, S ;
LANG, T ;
NICHOLS, K .
ANNALS OF INTERNAL MEDICINE, 1994, 121 (11) :894-895
[24]   USE OF CHECK LISTS IN ASSESSING THE STATISTICAL CONTENT OF MEDICAL STUDIES [J].
GARDNER, MJ ;
MACHIN, D ;
CAMPBELL, MJ .
BRITISH MEDICAL JOURNAL, 1986, 292 (6523) :810-812
[25]   IS THE STATISTICAL ASSESSMENT OF PAPERS SUBMITTED TO THE BRITISH MEDICAL JOURNAL EFFECTIVE [J].
GARDNER, MJ ;
ALTMAN, DG ;
JONES, DR ;
MACHIN, D .
BRITISH MEDICAL JOURNAL, 1983, 286 (6376) :1485-1488
[26]  
GONZALEZ C., 1999, MED BIOL ENG COMPUT, V37, P106
[27]   MANUSCRIPT QUALITY BEFORE AND AFTER PEER-REVIEW AND EDITING AT ANNALS OF INTERNAL-MEDICINE [J].
GOODMAN, SN ;
BERLIN, J ;
FLETCHER, SW ;
FLETCHER, RH .
ANNALS OF INTERNAL MEDICINE, 1994, 121 (01) :11-21
[28]   COMPARISON OF BIOIMPEDANCE SPECTROSCOPY AND MULTIFREQUENCY BIOIMPEDANCE ANALYSIS FOR THE ASSESSMENT OF EXTRACELLULAR AND TOTAL-BODY WATER IN SURGICAL PATIENTS [J].
HANNAN, WJ ;
COWEN, SJ ;
PLESTER, CE ;
FEARON, KCH ;
DEBEAU, A .
CLINICAL SCIENCE, 1995, 89 (06) :651-658
[29]  
Hardy RJ, 1998, STAT MED, V17, P841, DOI 10.1002/(SICI)1097-0258(19980430)17:8<841::AID-SIM781>3.0.CO
[30]  
2-D