Total body water measurement using bioelectrical impedance analysis, isotope dilution and total body potassium: a scoring system to facilitate intercomparison

被引:8
作者
Gonzalez, CH
Evans, JA
Smye, SW
Holland, P
机构
[1] Univ Caldas, Dept Phys, Manizales, Colombia
[2] Univ Leeds, Dept Med Phys, Leeds, W Yorkshire, England
[3] Univ Leeds, Dept Paediat, Leeds, W Yorkshire, England
关键词
bioelectrical impedance; dilution techniques; TBK; body water; scoring system;
D O I
10.1038/sj.ejcn.1601316
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objectives: (1) To develop a scale that is useful in evaluating the accuracy of multifrequency bioelectrical impedance analysis (MF-BIA) in the assessment of body water volumes against the accepted gold standard measurements based on isotope-dilution and total body potassium (TBK). (2) To perform a pilot test of the scale. Design: A scale was developed to evaluate the accuracy of MF-BIA in the assessment of body water volumes. Questions were obtained from reading the scientific literature and discussions involving the four authors. Three of these and two additional independent readers pre-tested the scale. A weighting was identified for each question and a pilot test with a sample of 10 articles (different to those used for the questionnaire performance) was conducted. A further validation was carried out with a second set of 20 articles and two additional independent readers. Results: The kappa statistic expressing the level of agreement between pairs of the first three authors using this scale with 10 articles, was 0.3, 0.4 and 0.6 after the first attempt. A second evaluation after specific changes improved the agreement to 0.8, 0.6 and 0.8. The mean score for 10 articles was 252 +/- 36 points from a total score of 400 (63 +/- 9%). The evaluation with the second set of 20 articles resulted in a kappa of 0.7 from two pairs of authors. The evaluation with two additional reviewers resulted in a kappa=0.7. Conclusion: A tool has been developed to assess the accuracy of the MF-BIA technique and to identify methodological components, plan future studies and critically evaluate data in this area. It is likely that this tool may also be used to assess the accuracy of single frequency studies. Sponsorship: COLCIENCIAS and University of Caldas, Colombia sponsor CH Gonzalez.
引用
收藏
页码:326 / 337
页数:12
相关论文
共 58 条
[2]   STATISTICAL GUIDELINES FOR CONTRIBUTORS TO MEDICAL JOURNALS [J].
ALTMAN, DG ;
GORE, SM ;
GARDNER, MJ ;
POCOCK, SJ .
BRITISH MEDICAL JOURNAL, 1983, 286 (6376) :1489-1493
[3]  
Altman DG, 1990, PRACTICAL STAT MED R
[4]   Bioimpedance spectroscopy technique: intra-, extracellular, and total body water [J].
Armstrong, LE ;
Kenefick, RW ;
Castellani, JW ;
Riebe, D ;
Kavouras, SA ;
Kuznicki, JT ;
Maresh, CM .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1997, 29 (12) :1657-1663
[5]   ANALYZING THE SAME DATA IN 2 WAYS - A DEMONSTRATION MODEL TO ILLUSTRATE THE REPORTING AND MISREPORTING OF CLINICAL-TRIALS [J].
BAAR, J ;
TANNOCK, I .
JOURNAL OF CLINICAL ONCOLOGY, 1989, 7 (07) :969-978
[6]   GUIDELINES FOR STATISTICAL REPORTING IN ARTICLES FOR MEDICAL JOURNALS - AMPLIFICATIONS AND EXPLANATIONS [J].
BAILAR, JC ;
MOSTELLER, F .
ANNALS OF INTERNAL MEDICINE, 1988, 108 (02) :266-273
[7]   IS THE CLINICAL-TRIAL EVIDENCE ABOUT NEW DRUGS STATISTICALLY ADEQUATE [J].
BLAND, JM ;
JONES, DR ;
BENNETT, S ;
COOK, DG ;
HAINES, AP ;
MACFARLANE, AJ .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1985, 19 (02) :155-160
[8]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]  
BRUMMER RJM, 1992, EUR J CLIN NUTR, V46, P47
[10]   A COHORT STUDY OF SUMMARY REPORTS OF CONTROLLED TRIALS [J].
CHALMERS, I ;
ADAMS, M ;
DICKERSIN, K ;
HETHERINGTON, J ;
TARNOWMORDI, W ;
MEINERT, C ;
TONASCIA, S ;
CHALMERS, TC .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1990, 263 (10) :1401-1405