Characterization of Leachates from 6 Root Canal Sealers

被引:40
作者
Elyassi, Yasaman [1 ,2 ]
Moinzadeh, Amir T. [2 ]
Kleverlaan, Cornelis J. [1 ]
机构
[1] Acad Ctr Tandheelkunde Amsterdam, Fac Dent, Dept Dent Mat, NL-1081 LA Amsterdam, Netherlands
[2] Acad Ctr Tandheelkunde Amsterdam, Fac Dent, Dept Endodontol, Amsterdam, Netherlands
关键词
Material characterization; solubility; leachates; root canal sealers; Biomaterials; PHYSICOCHEMICAL PROPERTIES; PHYSICAL-PROPERTIES; ENDODONTIC SEALERS; CALCIUM HYDROXIDE; SOLUBILITY; DENTIN; BIOACTIVITY; CEMENTS;
D O I
10.1016/j.joen.2019.01.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to evaluate 6 different endodontic sealers by characterizing their leachates and comparing their solubility in water over a 4-week period. Methods: The solubility of each sealer (Apexit Plus [Ivoclar Vivadent AG, Schaan, Liechtenstein], MTA Fillapex [Angelus Dental, Londrina, Brazil], AH Plus [Dentsply DeTrey, Konstanz, Germany], BioRoot RCS [Septodont, Saint-Maur-des-Fosses, France], Total Fill [FKG Dentaire SA, La Chaux-deFonds, Switzerland], and Obturys [Itena, Paris, France]) was tested according to the ISO specification 6876:2012 over a 4-week period. Residues were chemically analyzed using energy-dispersive X-ray spectroscopy. Solubility was analyzed using 2-way analysis of variance and elution with 1-way analysis of variance (P < .05). Results: At 24 hours, the solubility of the tested sealers was as follows: AH Plus, 0.0%; Obturys, 0.2%; Apexit Plus, 0.2%; Fillapex, 1.8%; Total Fill, 9.4%; and BioRoot RCS, 13.1%. BioRoot RCS was significantly more soluble than the other sealers, apart from Total Fill (P < .05). After 1 week, the solubility of Total Fill increased to 11.2%, significantly exceeding the solubility of AH Plus, Obturys, and Apexit Plus. After 2 weeks, MTA Fillapex (10.9%) was significantly more soluble than AH Plus, Obturys, and Apexit Plus. High levels of calcium were released from BioRoot RCS, Apexit Plus, MTA Fillapex, and Total Fill. AH Plus released mainly sodium and lanthanum, and Obturys showed an increase of silicon release over time. Conclusions: All sealers met ISO 6876:2012 regarding solubility (limit <3% at 24 hours) with the exception of Total Fill and BioRoot RCS. MTA Fillapex exceeded the limit after 1 week. High levels of calcium were released from all materials, except from the epoxy resin-based sealers.
引用
收藏
页码:623 / 627
页数:5
相关论文
共 33 条
  • [1] Long-term calcium hydroxide as a root canal dressing may increase risk of root fracture
    Andreasen, JO
    Farik, B
    Munksgaard, C
    [J]. DENTAL TRAUMATOLOGY, 2002, 18 (03) : 134 - 137
  • [2] Can bioactivity be tested in vitro with SBF solution?
    Bohner, Marc
    Lemaitre, Jacques
    [J]. BIOMATERIALS, 2009, 30 (12) : 2175 - 2179
  • [3] Changes in the surface of four calcium silicate-containing endodontic materials and an epoxy resin-based sealer after a solubility test
    Borges, R. P.
    Sousa-Neto, M. D.
    Versiani, M. A.
    Rached-Junior, F. A.
    De-Deus, G.
    Miranda, C. E. S.
    Pecora, J. D.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (05) : 419 - 428
  • [4] Long-term sealing ability of Pulp Canal Sealer, AH-Plus, GuttaFlow and Epiphany
    Bouillaguet, S.
    Shaw, L.
    Barthelemy, J.
    Krejci, I.
    Wataha, J. C.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2008, 41 (03) : 219 - 226
  • [5] THE PHYSICAL-PROPERTIES AND SEALING ACTION OF ENDODONTIC SEALER CEMENTS - A REVIEW OF THE LITERATURE
    BRANSTETTER, J
    VONFRAUNHOFER, JA
    [J]. JOURNAL OF ENDODONTICS, 1982, 8 (07) : 312 - 316
  • [6] Colombo Marco, 2018, J Clin Exp Dent, V10, pe120, DOI 10.4317/jced.54548
  • [7] Effect of bismuth oxide radioopacifier content on the material properties of an endodontic Portland cement-based (MTA-like) system
    Coomaraswamy, Kristian S.
    Lumley, Philip J.
    Hofmann, Michael P.
    [J]. JOURNAL OF ENDODONTICS, 2007, 33 (03) : 295 - 298
  • [8] Evaluation of Radiopacity, pH, Release of Calcium Ions, and Flow of a Bioceramic Root Canal Sealer
    de Miranda Candeiro, George Taccio
    Correia, Fabricia Campelo
    Hungaro Duarte, Marco Antonio
    Ribeiro-Siqueira, Danieli Colaco
    Gavini, Giulio
    [J]. JOURNAL OF ENDODONTICS, 2012, 38 (06) : 842 - 845
  • [9] Evaluation of physicochemical properties of four root canal sealers
    Flores, D. S. H.
    Rached-Junior, F. J. A.
    Versiani, M. A.
    Guedes, D. F. C.
    Sousa-Neto, M. D.
    Pecora, J. D.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (02) : 126 - 135
  • [10] Biological aspects of root canal filling materials--histocompatibility,cytotoxicity, and mutagenicity.
    Geurtsen W.
    Leyhausen G.
    [J]. Clinical Oral Investigations, 1997, 1 (1) : 5 - 11