Four quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients

被引:18
|
作者
Satish, Bhava R. J. [1 ]
Ranganadham, Atmakuri V. [2 ]
Ramalingam, Karruppasamy [1 ]
Tripathy, Sujit Kumar [3 ]
机构
[1] BRJ Ortho Ctr, Coimbatore, Tamil Nadu, India
[2] Sree Ortho Clin, Behrampur, Odisha, India
[3] KMC Hosp, Manipal, Karnataka, India
关键词
Femoral neck fracture; osteosynthesis; four quadrant parallel screw fixation; TOTAL HIP-REPLACEMENT; INTERNAL-FIXATION; INTRACAPSULAR FRACTURES; OPERATIVE MANAGEMENT; ARTHROPLASTY;
D O I
10.4103/0019-5413.108912
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The treatment options for displaced femoral neck fracture in elderly are screw fixation, hemiarthroplasty and total hip arthroplasty based primarily on age of the patient. The issues in screw fixation are ideal patient selection, optimal number of screws, optimal screw configuration and positioning inside the head and neck of femur. The problems of screw fixation may be loss of fixation, joint penetration, avascular necrosis of femoral head, nonunion, prolonged rehabilitation period and the need for second surgery in failed cases. We hereby present results of a modified screw fixation technique in femoral neck fractures in patients >= 50 years of age. Materials and Methods: Patients >= 50 years of age (range 50-73 years) who sustained displaced femoral neck fracture and fulfilled the inclusion criteria were enrolled in this prospective study. They were treated with closed reduction under image intensifier control and cannulated cancellous screw fixation. Accurate anatomical reduction was not aimed and a cross sectional contact area of >75% without varus was accepted as good reduction. Four screws were positioned in four quadrants of femoral head and neck, as parallel and as peripheral as possible. Radiological and functional results were evaluated periodically. Sixty four patients who could complete a minimum followup of two years were analyzed. Results: Radiologically, all fractures healed after mean duration of 10 weeks (range 8-12 weeks). There was no avascular necrosis. Nonanatomical healing was observed in 45 cases (70%). All patients except one had excellent functional outcome and could do cross-legged sitting and squatting. Chondrolysis with progressive head resorption was seen in one case, which was converted to total hip arthroplasty. Conclusion: Closed reduction and cannulated cancellous screw fixation gives satisfactory functional results in large group of elderly patients. The four quadrant parallel peripheral (FQPP) screw fixation technique gives good stability, allows controlled collapse, avoids fixation failure and achieves predictable bone healing in displaced femoral neck fracture in patients >= 50 years of age.
引用
收藏
页码:174 / 181
页数:8
相关论文
共 50 条
  • [41] Biomechanics of Femoral Neck Fractures and Implications for Fixation
    Augat, Peter
    Bliven, Emily
    Hackl, Simon
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 : S27 - S32
  • [42] Results of Cephallomedullary Nail Fixation for Displaced Intracapsular Femoral Neck Fractures
    Mir, Hassan R.
    Edwards, Paul
    Sanders, Roy
    Haidukewych, George
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (12) : 714 - 720
  • [43] Radiographic fracture features predicting failure of internal fixation of displaced femoral neck fractures
    Weil, N. L.
    van Embden, D.
    Hoogendoorn, J. M.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2015, 41 (05) : 501 - 507
  • [44] Low reoperation rate after fixation of displaced femoral neck fractures with the femoral neck system (FNS)
    Obey, Mitchel R.
    Falgons, Christian G.
    Eastman, Jonathan G.
    Choo, Andrew M.
    Achor, Timothy S.
    Munz, John W.
    Warner, Stephen J.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (05) : 2581 - 2588
  • [45] Outcomes after fixation for undisplaced femoral neck fracture compared to hemiarthroplasty for displaced femoral neck fracture among the elderly
    Lin, Jeff Chien-Fu
    Liang, Wen-Miin
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [46] Comparative Short-Term Outcomes of Femoral Neck System (FNS) and Cannulated Screw Fixation in Patients with Femoral Neck Fractures: A Multicenter Study
    Chung, HoeJeong
    Kim, Youngwoo
    Kook, Incheol
    Kwak, Ji Woong
    Hwang, Kyu Tae
    CLINICS IN ORTHOPEDIC SURGERY, 2024, 16 (02) : 184 - 193
  • [47] The choice of screw internal fixation and hemiarthroplasty in the treatment of femoral neck fractures in the elderly: a meta-analysis
    Shuai Cui
    Dehui Wang
    Xuejie Wang
    Zehui Li
    Wenlai Guo
    Journal of Orthopaedic Surgery and Research, 15
  • [48] Treatment of the displaced femoral neck fractures: indications and limits of osteosynthesis
    I. Flóris
    P. Cserháti
    J. Baktai
    T. Gál
    B. Gloviczki
    Z. Vendégh
    European Journal of Trauma and Emergency Surgery, 2011, 37 : 277 - 285
  • [49] Screw augmentation in displaced femoral neck fractures - Clinical and histological results using a new composite
    Frihagen, F.
    Madsen, J. E.
    Reinholt, F. P.
    Nordsletten, L.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (07): : 797 - 805
  • [50] Performing Screw Fixation for Femoral Neck Fractures under Local Anaesthesia
    Chor-Yat, Chung
    Wong Sze-Hung
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2012, 16 (02) : 55 - 58