Sensitive Determination of Anticancer Drug Methotrexate Using Graphite Oxide-Nafion Modified Glassy Carbon Electrode

被引:18
作者
Huang, Deqian [1 ,2 ]
Wu, Hai [1 ,2 ]
Zhu, Yuyang [1 ,2 ]
Su, Huijuan [1 ,2 ]
Zhang, Hong [1 ,2 ]
Sheng, Liangquan [1 ,2 ]
Liu, Zhaodi [1 ,2 ]
Xu, Huajie [1 ,2 ]
Song, Chongfu [1 ,2 ]
机构
[1] Fuyang Normal Univ, Sch Chem & Mat Engn, Fuyang 236037, Anhui, Peoples R China
[2] Anhui Prov Key Lab Degradat & Monitoring Pollut E, Fuyang, Anhui, Peoples R China
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2019年 / 14卷 / 04期
关键词
anticancer drug; methotrexate; graphite oxide-Nafion; determination; ELECTROCHEMICAL OXIDATION FLUOROMETRY; STRIPPING VOLTAMMETRIC DETERMINATION; HIGH-DOSE METHOTREXATE; FOLIC-ACID; SENSOR; CHROMATOGRAPHY; ADSORPTION; THERAPY; EPIRUBICIN; NANOTUBES;
D O I
10.20964/2019.04.03
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this paper, a graphite oxide-Nafion-glassy carbon electrode (GO-Nafion-GCE) by coating method was fabricated and used for study the electrochemical behavior and measurement of methotrexate (MTX) by cycle voltammetry (CV). The influence factors, such as volume of modifier, type of supporting electrolyte, concentration of electrolyte, scan rate, preconcentration time, and preconcentration potential on the anodic peak current of MTX were examined. The experimental results indicated that the electrode process is an adsorption-diffusion mixed controlled process. Under the experimental conditions of research, the anodic peak current of MTX shows a linear relationship within concentration range of 4.0 x 10(-7). 2.0 x 10(-5) mol L-1. The linear relationship can be expressed with the equation of I-p,I-a(mu A) = (0.4739 +/- 0.0086) C(mu M) + (0.2885 +/- 0.0434). Under the optimum electrochemical experimental conditions, the limit of detection (LOD) can be calculated to be 9.0 x 10(-9) mol L-1 (S/N=3). The proposed method has been used for the detection of MTX in methotrexate injection and urine samples successfully.
引用
收藏
页码:3792 / 3804
页数:13
相关论文
共 54 条
[1]   ALK inhibitor crizotinib combined with intrathecal methotrexate treatment for non-small cell lung cancer with leptomeningeal carcinomatosis [J].
Ahn, Hee Kyung ;
Han, Boram ;
Lee, Su Jin ;
Lim, Taekyu ;
Sun, Jong-Mu ;
Ahn, Jin Seok ;
Ahn, Myung-Ju ;
Park, Keunchil .
LUNG CANCER, 2012, 76 (02) :253-254
[2]   Glassy carbon electrode modified with 3D graphene-carbon nanotube network for sensitive electrochemical determination of methotrexate [J].
Asadian, Elham ;
Shahrokhian, Saeed ;
Zad, Azam Iraji ;
Ghorbani-Bidkorbeh, Fatemeh .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 :617-627
[3]   Differential pulse adsorptive stripping voltammetric determination of nanomolar levels of methotrexate utilizing bismuth film modified electrodes [J].
Asbahr, Deborah ;
Figueiredo-Filho, Luiz Carlos S. ;
Vicentini, Fernando Campanha ;
Oliveira, Geiser Gabriel ;
Fatibello-Filho, Orlando ;
Banks, Craig E. .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 :334-339
[4]  
Cameron D, 2017, LANCET ONCOL, V18, P929, DOI [10.1016/s1470-2045(17)30404-7, 10.1016/S1470-2045(17)30404-7]
[5]   Molecularly imprinted solid-phase extraction combined with electrochemical oxidation fluorimetry for the determination of methotrexate in human serum and urine [J].
Chen, Suming ;
Zhang, Zhujun .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2008, 70 (01) :36-41
[6]   Flow-injection-electrochemical oxidation fluorimetry for determination of methotrexate [J].
Chen, Suming ;
Zhang, Zhujun ;
He, Deyong ;
Hu, Yufei ;
Zheng, Huzhi ;
He, Chao .
LUMINESCENCE, 2007, 22 (04) :338-342
[7]   Biomarkers predict enhanced clinical outcomes with afatinib versus methotrexate in patients with second-line recurrent and/or metastatic head and neck cancer [J].
Cohen, E. E. W. ;
Licitra, L. F. ;
Burtness, B. ;
Fayette, J. ;
Gauler, T. ;
Clement, P. M. ;
Grau, J. J. ;
del Campo, J. M. ;
Mailliez, A. ;
Haddad, R. I. ;
Vermorken, J. B. ;
Tahara, M. ;
Guigay, J. ;
Geoffrois, L. ;
Merlano, M. C. ;
Dupuis, N. ;
Kraemer, N. ;
Cong, X. J. ;
Gibson, N. ;
Solca, F. ;
Ehrnrooth, E. ;
Machiels, J. -P. H. .
ANNALS OF ONCOLOGY, 2017, 28 (10) :2526-2532
[8]   An electrochemical sensor for dopamine based on polydopamine modified reduced graphene oxide anchored with tin dioxide and gold nanoparticles [J].
Cui, Xiaoqing ;
Fang, Xian ;
Zhao, Hong ;
Li, Zengxi ;
Ren, Hongxuan .
ANALYTICAL METHODS, 2017, 9 (36) :5322-5332
[9]   Kinetic fluorimetric determination of the antineoplastic methotrexate (MTX) in human serum [J].
Espinosa-Mansilla, A ;
Merás, ID ;
Madera, AZ ;
Pedano, L ;
Ferreyra, C .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (05) :851-858
[10]   PERMEABILITY OF GLUCOSE AND OTHER NEUTRAL SPECIES THROUGH RECAST PERFLUOROSULFONATED IONOMER FILMS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1992, 64 (11) :1304-1311