The placement of lumbar pedicle screws using computerised stereotactic guidance

被引:70
作者
Girardi, FP [1 ]
Cammisa, FP [1 ]
Sandhu, HS [1 ]
Alvarez, L [1 ]
机构
[1] Cornell Univ, Weill Med Coll, Hosp Special Surg, Spine Serv, New York, NY 10021 USA
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1999年 / 81B卷 / 05期
关键词
D O I
10.1302/0301-620X.81B5.9244
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Computer-assisted frameless stereotactic image guidance allows precise preoperative planning and intraoperative localisation of the image, It has been developed and tested in the laboratory. We evaluated the efficacy, clinical results and complications of placement of a pedicle screw in the lumbar spine using this technique, A total of 62 patients (28 men, 34 women) had lumbar decompression and spinal fusion with segmental pedicle screws, Postoperative CT scans were taken of 35 patients to investigate the placement of 330 screws. None showed penetration of the medial or inferior wall of a pedicle, Registration was carried out 66 times. The number of fiducial points used on each registration averaged 5.8 (4 to 7) The mean registration error was 0.75 mm (0.32 to 1.72). This technique provides a safe and reliable guide for placement of transpedicular screws in the lumbar spine.
引用
收藏
页码:825 / 829
页数:5
相关论文
共 23 条
[1]   COMPUTER-ASSISTED PEDICLE SCREW FIXATION - A FEASIBILITY STUDY [J].
AMIOT, LP ;
LABELLE, H ;
DEGUISE, JA ;
SATI, M ;
BRODEUR, P ;
RIVARD, CH .
SPINE, 1995, 20 (10) :1208-1212
[2]   USE OF A FRAMELESS, ARMLESS STEREOTAXIC WAND FOR BRAIN-TUMOR LOCALIZATION WITH 2-DIMENSIONAL AND 3-DIMENSIONAL NEUROIMAGING [J].
BARNETT, GH ;
KORMOS, DW ;
STEINER, CP ;
WEISENBERGER, J .
NEUROSURGERY, 1993, 33 (04) :674-678
[3]  
Berlemann U, 1997, J SPINAL DISORD, V10, P117
[4]   STIMULUS-EVOKED EMG MONITORING DURING TRANSPEDICULAR LUMBOSACRAL SPINE INSTRUMENTATION - INITIAL CLINICAL-RESULTS [J].
CALANCIE, B ;
MADSEN, P ;
LEBWOHL, N .
SPINE, 1994, 19 (24) :2780-2786
[5]   In vitro simulation - Early results of stereotaxy for pedicle screw placement [J].
Carl, AL ;
Khanuja, HS ;
Sachs, BL ;
Gatto, CA ;
vomLehn, J ;
Vosburgh, K ;
Schenck, J ;
Lorensen, W ;
Rohling, K ;
Disler, D .
SPINE, 1997, 22 (10) :1160-1164
[6]   Accuracy of pedicle screw placement in lumbar vertebrae [J].
Castro, WHM ;
Halm, H ;
Jerosch, J ;
Malms, J ;
Steinbeck, J ;
Blasius, S .
SPINE, 1996, 21 (11) :1320-1324
[7]  
DARDEN BV, 1996, P SCOL RES SOC, P175
[8]  
Foley KT, 1996, NEUROSURG CLIN N AM, V7, P171
[9]   INTRACRANIAL NEUROSURGERY GUIDED BY FUNCTIONAL IMAGING [J].
GALLEN, CC ;
BUCHOLZ, R ;
SOBEL, DF .
SURGICAL NEUROLOGY, 1994, 42 (06) :523-530
[10]  
GUTHRIE BL, 1992, CLIN NEUR, V38, P112