Determination of acetaminophen by electrochemical co-deposition of glutamic acid and gold nanoparticles

被引:101
作者
Bui, Minh-Phuong Ngoc [1 ]
Li, Cheng Ai [1 ]
Han, Kwi Nam [1 ]
Pham, Xuan-Hung [1 ]
Seong, Gi Hun [1 ]
机构
[1] Hanyang Univ, Dept Bionano Engn, Ansan 426791, South Korea
关键词
Acetaminophen; Ascorbic acid; Single-walled carbon nanotube; Gold nanoparticle; Glutamic acid; Differential pulse voltammetry; GLASSY-CARBON ELECTRODE; INDIUM TIN OXIDE; POLY(GLUTAMIC ACID); VOLTAMMETRIC DETERMINATION; SENSITIVE DETECTION; SELECTIVE DETECTION; ASCORBIC-ACID; URIC-ACID; PARACETAMOL; DOPAMINE;
D O I
10.1016/j.snb.2012.08.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We developed an electrochemical sensor to detect acetaminophen by electrochemically co-depositing glutamic acid and gold nanoparticles on a single-walled carbon nanotube film (AuNP-PGA/SWCNT). Cyclic voltammetry indicated that the electrochemical oxidation of acetaminophen at the AuNP-PGA/SWCNT film electrode involved a two-electron, one-proton process and was pH dependent. Different pulse voltammograms of acetaminophen oxidation on the AuNP-PGA/SWCNT film electrode yielded a well-defined oxidation peak at 360 mV in 0.1 M phosphate buffered saline buffer (pH 7.2) with linear calibration from 8.3 to 145.6 mu M (R-2=0.997). The detection limit was estimated to be 1.18 mu M. The proposed sensor is stable and reproducible from 1.15 to 5.21% with a relative standard deviation of 3.56%. The AuNP-PGA/SWCNT film electrode was able to detect acetaminophen in the presence of interfering ascorbic acid; two well-defined oxidation peaks, one for ascorbic acid at 0.15V and the other for acetaminophen at 0.39V, were detected. Furthermore, the fabricated sensor accurately measured the amount of acetaminophen in pharmaceutical samples. Together, these results indicate that our AuNP-PGA/SWCNT film is a promising platform for accurate and reproducible detection of acetaminophen. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:318 / 324
页数:7
相关论文
共 50 条
[41]   Simpler spectrophotometric assay of paracetamol in tablets and urine samples [J].
Sirajuddin ;
Khaskheli, Abdul Rauf ;
Shah, Afzal ;
Bhanger, Muhammad Lqbal ;
Niaz, Abdul ;
Mahesar, Sarfaraz .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2007, 68 (03) :747-751
[42]   Clinical Report-Fever and Antipyretic Use in Children [J].
Sullivan, Janice E. ;
Farrar, Henry C. .
PEDIATRICS, 2011, 127 (03) :580-587
[43]   Simultaneous electrochemical detection of uric acid and ascorbic acid at a silver doped poly(glutamic acid) modified glassy carbon electrode [J].
Sun, D. M. ;
Hu, W. N. ;
Ma, W. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (03) :310-316
[44]  
Tietz N.W., 1995, Clinical Guide to Laboratory Tests, V3rd
[45]   Electrochemical determination of acetaminophen based on TiO2-graphene/poly(methyl red) composite film modified electrode [J].
Xu, Chun-Xuan ;
Huang, Ke-Jing ;
Fan, Yang ;
Wu, Zhi-Wei ;
Li, Jing .
JOURNAL OF MOLECULAR LIQUIDS, 2012, 165 :32-37
[46]   Electrocatalytic oxidation of hydrazine at the poly(glutamic acid) chemically modified electrode and its amperometric determination [J].
Yu, AM ;
Chen, HY .
ANALYTICAL LETTERS, 1997, 30 (03) :599-607
[47]   Simultaneous determination of caffeine and acetaminophen in drug formulations by square-wave voltammetry using a chemically modified electrode [J].
Zen, JM ;
Ting, YS .
ANALYTICA CHIMICA ACTA, 1997, 342 (2-3) :175-180
[48]   A highly sensitive method for determination of paracetamol by adsorptive stripping voltammetry using a carbon paste electrode modified with nanogold and glutamic acid [J].
Zhang, Ying ;
Luo, Liqiang ;
Ding, Yaping ;
Liu, Xiao ;
Qian, Zheyuan .
MICROCHIMICA ACTA, 2010, 171 (1-2) :133-138
[49]   Carbon Nanotube/Hexa-peri-hexabenzocoronene Bilayers for Discrimination Between Nonpolar Volatile Organic Compounds of Cancer and Humid Atmospheres [J].
Zilberman, Yael ;
Tisch, Ulrike ;
Shuster, Gregory ;
Pisula, Wojciech ;
Feng, Xinliang ;
Muellen, Klaus ;
Hoick, Hossam .
ADVANCED MATERIALS, 2010, 22 (38) :4317-+
[50]   Sensitive and Selective Detection of Dopamine Using a DNA Immobilized Ethylenedidamine/Polyglutamic Modified Electrode [J].
Zou, Lina ;
Luo, Peili ;
Li, Yamin ;
Zhang, Shusheng ;
Ye, Baoxian .
ELECTROANALYSIS, 2011, 23 (06) :1435-1441