Gypsum scaling on anion exchange membranes during Donnan exchange

被引:18
作者
Asraf-Snir, Meital [1 ]
Gilron, Jack [1 ]
Oren, Yoram [1 ]
机构
[1] Ben Gurion Univ Negev, Dept Desalinat & Water Treatment, Zuckerberg Inst Water Res, Unit Environm Engn, IL-84105 Beer Sheva, Israel
关键词
Ion exchange membranes; Scaling; CaSO4; Dorman exchange; Electrodialysis; ELECTRODIALYSIS REVERSAL; CALCIUM-SULFATE; DESALINATION PLANTS; ION; CONCENTRATE; POLARIZATION; DISCHARGE;
D O I
10.1016/j.memsci.2013.12.065
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The formation of gypsum (CaSa(4) center dot 2H(2)O) scale in ion exchange membranes was investigated under a Dorman exchange regime. Two types of anion exchange membranes (AEM), homogeneous AMV and heterogeneous MA-40, were used for the study. Counter-ion flux, scaling-cation concentration in the Fouled membrane and membrane potential served as indicators for membrane scaling. Locations of scaling domains were dependent on the membrane structure, and lead to different effects On the membrane performance. Scaling in the homogeneous membrane was mainly characterized by surface deposits, resulting in a moderate decrease of the counter-ion flux. On the other hand, the heterogeneous membrane showed a high degree of internal precipitation resulting in a complete clogging of the membrane. thus leading to earlier and more severe decline in counter-ion flux. Significant amounts of calcium were found within the fouled MA-40, supporting the other indications of internal scaling. The potential difference across the homogeneous AMV did not change significantly after operating under scaling conditions. However, for the MA-40, an increase of the membrane potential was observed, suggesting that CaSO4 scale blocks defects and imperfections in the heterogeneous maLrix. Scaling experiments were conducted in a specially designed Donnan cell with optical apparatus for in-situ observation of scales. This allowed real-time observation of surface scaling on the ion exchange membranes. Gypsum growth centers were observed on the homogeneous AMV significantly earlier than flux decline appeared. This finding shows that it is feasible to detect onset of scaling on homogeneous anion-exchange membranes before the appearance of significant effects on membrane performance. (C) 2014 Published by Elsevier B.V.
引用
收藏
页码:384 / 391
页数:8
相关论文
共 34 条
[1]   Brine disposal from reverse osmosis desalination plants in Oman and the United Arab Emirates [J].
Ahmed, M ;
Shayya, WH ;
Hoey, D ;
Al-Handaly, J .
DESALINATION, 2001, 133 (02) :135-147
[2]  
Andrew D., 2005, STANDARD METHODS EXA
[3]  
[Anonymous], 2004, ION EXCHANGE MEMBRAN
[4]   Study of the scaling process on membranes [J].
Atamanenko, I ;
Kryvoruchko, A ;
Yurlova, L .
DESALINATION, 2004, 167 (1-3) :327-334
[5]   Optimized brackish water desalination plants with minimum impact on the environment [J].
Glueckstern, P ;
Priel, M .
DESALINATION, 1997, 108 (1-3) :19-26
[6]   PERMSELECTIVITY OF CALCIUM-ION TO POTASSIUM-ION IN ION-EXCHANGE MEMBRANE ELECTRODIALYSIS OF SUGAR SOLUTION [J].
HUANG, TC ;
YU, TM .
CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1983, 26 (02) :119-125
[7]   INTERDIFFUSION OF COUNTERIONS IN A CATION-EXCHANGE MEMBRANE [J].
HUANG, TC ;
LIAN, PH .
INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1979, 18 (03) :221-226
[8]   ELECTRODIALYSIS REVERSAL (EDR) PROCESS [J].
KATZ, WE .
DESALINATION, 1979, 28 (01) :31-40
[9]   Electrodialysis with brine solutions oversaturated with calcium sulfate [J].
Korngold, E ;
Aronov, L ;
Belayev, N ;
Kock, K .
DESALINATION, 2005, 172 (01) :63-75
[10]   Electrodialysis of brine solutions discharged from an RO plant [J].
Korngold, E. ;
Aronov, L. ;
Daltrophe, N. .
DESALINATION, 2009, 242 (1-3) :215-227