Ceramic acetabular cups for total hip replacement - Part 6: Cup design, inclination angle and antetorsion angle have an influence on the range of motion and impingement

被引:39
作者
Bader, R
Willmann, G
机构
[1] CeramTec AG, D-73207 Plochingen, Germany
[2] FHU Hsch Tech Ulm, Fachbereich Feinwerktech, Ulm, Germany
来源
BIOMEDIZINISCHE TECHNIK | 1999年 / 44卷 / 7-8期
关键词
hip endoprostheses; ceramic-on-ceramic; cup design; ceramic insert; impingement; dislocation;
D O I
10.1515/bmte.1999.44.7-8.212
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The present investigation focuses on total hip replacement using ceramic acetabular components. The relationship between the position of the cup and the range of motion (ROM) was investigated. A Limited range of motion may cause impingement, which is defined as contact between the femoral neck and the rim of the acetabular cup. Impingement may result in wear, chipping; fracture or dislocation of the femoral head. Joint movements were simulated in a three-dimensional CAD program. The results obtained underscore the importance of correct positioning and design of the cup for achieving a ROM as close to the physiological situation as possible. With ceramic cups, the inclination angle should not be more than 45 degrees, and the antetorsion angle between 10 and 15 degrees. If the cup is too vertical, the risk of dislocation and fracture of the ceramic increases. If, on the other hand, the angle of inclination is too small, flexion and abduction will be greatly limited. The study shows that acetabular components with non-recessed ceramic inserts should not be used. Slight recession of the insert helps to avoid impingement. The ROM is reduced and the risk of impingement appreciably increased when mushroom-shaped femoral heads (XL heads) or ceramic inserts protected by a polyethylene ring are used.
引用
收藏
页码:212 / 219
页数:8
相关论文
共 16 条
[1]  
AMSTUTZ HC, 1975, CLIN ORTHOP RELAT R, P124
[2]  
Debrunner A. M., 1994, ORTHOPADIE ORTHOPADI
[3]  
GEKELER J, 1998, BIOCERAMICS ORTHOPAE, P32
[4]  
JARAMAZ B, 1997, LECT NOTES COMPUTER, P573
[5]  
LAVERNIA C, 1998, SCI EXH AAOS M NEW O
[6]  
MCCLOLLUM DE, 1990, CLIN ORTHOPAEDICS, V261, P159
[7]  
Morscher EW, 1995, ENDOPROTHETIK
[8]  
PUHL W, 1997, PERFORMANCE WEAR COU
[9]  
PUHL W, 1998, BIOCERAMICS ORTHOPAE
[10]   Joint motion and surface contact area related to component position in total hip arthroplasty [J].
Robinson, RP ;
Simonian, PT ;
Gradisar, IM ;
Ching, RP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (01) :140-146