摘要
A prototype instrument for in situ measurements of the volume scattering function (VSF) and the beam attenuation of water has been built and tested in the EOO laboratory. The intended application of the instrument is the enhancement of Navy operational optical systems for finding and imaging underwater objects such as mines. A description of the apparatus that was built and preliminary laboratory data will be presented. The instrument measures the VSF, beta (theta), near the optical axis in both the forward and back directions from similar to 0.2 degrees off axis to similar to 5 degrees in 0.1 degrees steps and at side angles of 45 degrees, 90 degrees, and 135 degrees. A diode-pumped, frequency-doubled, Nd:YAG laser provides the 532 nm light. This is the most used wavelength for underwater optical systems. The forward and back scattered light is collected and focused to a plane where scattering angles in the water are mapped onto concentric rings. Al this focal plane, a conical reflector compresses the annular optical data onto a line along the cone axis where it is read by a MOS linear image array providing over 500 separate angular measurements. The beam attenuation coefficient, c, is also measured by means of a unique dual path configuration.
引用
收藏
页码:658 / 663
页数:2
相关论文
共 50 条
  • [1] VOLUME SCATTERING FUNCTION MEASUREMENT ERROR - EFFECT OF ANGULAR RESOLUTION OF THE NEPHELOMETER
    JONASZ, M
    APPLIED OPTICS, 1990, 29 (01): : 64 - 70
  • [2] HIGH ANGULAR RESOLUTION MEASUREMENTS OF ALGOL
    PAN, XP
    SHAO, M
    COLAVITA, MM
    ASTROPHYSICAL JOURNAL, 1993, 413 (02): : L129 - L131
  • [3] HIGH-RESOLUTION SONAR VOLUME SCATTERING MEASUREMENTS IN MARINE-SEDIMENTS
    LEBLANC, LR
    SCHOCK, SG
    DEBRUIN, DL
    JENKINS, M
    MUNRO, L
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (05): : 2979 - 2986
  • [4] ANGULAR-DEPENDENCE LIGHT SCATTERING - A HIGH-RESOLUTION RECORDING INSTRUMENT FOR THE ANGULAR RANGE 0.05-140-DEGREES
    AUGHEY, WH
    BAUM, FJ
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1954, 44 (11) : 833 - 837
  • [5] HIGH ANGULAR RESOLUTION MEASUREMENTS OF STELLAR PROPERTIES
    MCALISTER, HA
    ANNUAL REVIEW OF ASTRONOMY AND ASTROPHYSICS, 1985, 23 : 59 - 87
  • [6] Plasmon spectroscopy for high resolution angular measurements
    Schaller, JK
    Czepluch, R
    Stojanoff, CG
    OPTICAL INSPECTION AND MICROMEASUREMENTS II, 1997, 3098 : 476 - 486
  • [7] CHARM: A catalog of high angular resolution measurements
    Richichi, A
    Percheron, I
    ASTRONOMY & ASTROPHYSICS, 2002, 386 (02) : 492 - 503
  • [8] Measurements of the Volume Scattering Function in a coastal environment
    Berthon, Jean-Francois
    Lee, Michael
    Shybanov, Eugeny
    Zibordi, Giuseppe
    CURRENT RESEARCH ON REMOTE SENSING, LASER PROBING, AND IMAGERY IN NATURAL WATERS, 2007, 6615
  • [9] ANGULAR-DEPENDENCE LIGHT SCATTERING - A HIGH RESOLUTION RECORDING INSTRUMENT FOR THE ANGULAR RANGE 0.05-DEGREES TO 140-DEGREES
    AUGHEY, WH
    BAUM, FJ
    ANALYTICAL CHEMISTRY, 1954, 26 (04) : 786 - 786
  • [10] Forward scattering measurement device with a high angular resolution
    Rosskamp, David
    Truffer, Frederic
    Bolay, Sylvain
    Geiser, Martial
    OPTICS EXPRESS, 2007, 15 (05) : 2683 - 2690