Macromolecular inversion-driven polymer insertion into model lipid bilayer membranes

被引:14
|
作者
Ramadurai, Sivaramakrishnan [1 ]
Kohut, Ananiy [2 ,3 ]
Sarangi, Nirod Kumar [1 ]
Zholobko, Oksana [2 ]
Baulin, Vladimir A. [4 ]
Voronov, Andriy [2 ]
Keyes, Tia E. [1 ]
机构
[1] Dublin City Univ, Sch Chem Sci, Dublin 9, Ireland
[2] North Dakota State Univ, Dept Coatings & Polymer Mat, Fargo, ND 58105 USA
[3] Lviv Polytech Natl Univ, Dept Organ Chem, Vul S Bandery 12, UA-79013 Lvov, Ukraine
[4] Univ Rovira & Virgili, Dept Enginyeria Quim, Av Dels Paisos Catalans 26, Tarragona 43007, Spain
基金
爱尔兰科学基金会;
关键词
Microcaviry supported lipid bilayer (MSLB); Fluorescence lifetime correlation spectroscopy (FLCS); Electrochemical impedance spectroscopy (EIS); Amphiphilic invertible polymer micelles; Lipid probes; 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC); Diffusion coefficient; Impedance; FLUORESCENCE CORRELATION SPECTROSCOPY; INVERTIBLE POLYMER; DIFFUSION; CELL;
D O I
10.1016/j.jcis.2019.01.093
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Macromolecules of amphiphilic invertible polymers (AIPs) are capable of self-assembly into micellar assemblies of various morphologies in solvents of different polarities. The micellar assemblies in aqueous media are capable of encapsulating poorly aqueous soluble cargo and can undergo inverse conformational change and cargo release in contact with non-polar media, including potentially, cell membranes. Thus, invertible micellar assemblies have significant potential in drug delivery and related domains. However, to date there have been few investigations into their interactions with lipid membranes. Herein, we investigate the interactions of three recently developed AlPs of varying hydrophobicity/hydrophilicity balance with a highly fluidic microcavity supported 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) lipid bilayer. We combined electrochemical impedance spectroscopy (EIS) with fluorescence correlation spectroscopy (FCS) to understand how the AIP micellar assemblies impacted bilayer permeability and fluidity respectively, across polymer concentrations above and below their critical micelle concentrations (cmcs). At concentration as above their cmcs, all of the AlPs explored increased permeability and decreased the fluidity of the lipid membrane. The extent of impact depended on the hydrophobicity of the AIP. PEG(600)-PTHF650 , the most hydrophobic of the polymers, synthesized from PEG (molecular weight 600 g/mol) and PTHF (molecular weight 650 g/mol) exerted the greatest influence on the bilayer's physical properties and fluorescence imaging and correlation data indicate that PEG(600)-PTHF650 micelles loaded with BODIPY probes adsorb and invert at the lipid membrane with release of cargo into the bilayer. This study should help inform future advancement of AIPs for membrane molecular delivery. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:483 / 494
页数:12
相关论文
共 4 条
  • [1] Hybrid Model Membrane Combining Micropatterned Lipid Bilayer and Hydrophilic Polymer Brush
    Nishimura, Toshiki
    Tamura, Fuyuko
    Kobayashi, Sawako
    Tanimoto, Yasushi
    Hayashi, Fumio
    Sudo, Yuki
    Iwasaki, Yasuhiko
    Morigaki, Kenichi
    LANGMUIR, 2017, 33 (23) : 5752 - 5759
  • [2] Photosynthetic Model Membranes of Natural Plant Thylakoid Embedded in a Patterned Polymeric Lipid Bilayer
    Yoneda, Takuro
    Tanimoto, Yasushi
    Takagi, Daisuke
    Morigaki, Kenichi
    LANGMUIR, 2020, 36 (21) : 5863 - 5871
  • [3] Continuity of Monolayer-Bilayer Junctions for Localization of Lipid Raft Microdomains in Model Membranes
    Ryu, Yong-Sang
    Wittenberg, Nathan J.
    Suh, Jeng-Hun
    Lee, Sang-Wook
    Sohn, Youngjoo
    Oh, Sang-Hyun
    Parikh, Atul N.
    Lee, Sin-Doo
    SCIENTIFIC REPORTS, 2016, 6
  • [4] Interplay of electrostatics and lipid packing determines the binding of charged polymer coated nanoparticles to model membranes
    Biswas, Nupur
    Bhattacharya, Rupak
    Saha, Arindam
    Jana, Nikhil R.
    Basu, Jaydeep K.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2015, 17 (37) : 24238 - 24247