Artificial Pneumothorax With Position Adjustment for Computed Tomography-Guided Percutaneous Core Biopsy of Mediastinum Lesions

被引:15
作者
Lin, Zheng-Yu [1 ]
Li, Yin-Guan [1 ]
机构
[1] Fujian Med Univ, Affiliated Hosp 1, Dept Radiol, Fuzhou 350005, Peoples R China
关键词
NEEDLE-BIOPSY; PROTECTIVE PNEUMOTHORAX;
D O I
10.1016/j.athoracsur.2008.10.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. This study was designed to assess the use of artificial pneumothorax with position adjustment to gain a pleural space approach in computed tomographic-guided core biopsy of mediastinal masses. Description. Eleven patients with mediastinal lesions who were undergoing percutaneous core biopsies received an artificial pneumothorax with a 22-gauge lumbar puncture needle. Each patient's position was adjusted to place the lesion as high as possible in the thoracic cavity. Air was injected until the lung was displaced from the path of the biopsy needle. After completion of the biopsy, a comparable volume of air was aspirated. Evaluation. In all patients, satisfactory displacement of the lung from the biopsy site was achieved with the artificial pneuomothorax procedure enabling the target lesion to be reached. No postoperative air leaks requiring tube drainage were encountered. Conclusions. Artificial pneumothorax with position adjustment is a safe and effective method that provides access for computed tomographic-guided biopsy of mediastinal lesions without the risks of traversing aerated lung tissue and with a relatively low volume of injected air.
引用
收藏
页码:920 / 924
页数:5
相关论文
共 11 条
[1]   MEDIASTINAL MASSES - ALTERNATIVE APPROACHES TO CT-GUIDED NEEDLE-BIOPSY [J].
BRESSLER, EL ;
KIRKHAM, JA .
RADIOLOGY, 1994, 191 (02) :391-396
[2]   CT-guided percutaneous needle biopsy of intrathoracic lesions by using the transsternal approach: Experience in 37 patients [J].
Gupta, S ;
Wallace, MJ ;
Morello, FA ;
Ahrar, K ;
Hicks, ME .
RADIOLOGY, 2002, 222 (01) :57-62
[3]   COMPLICATIONS AFTER CT-GUIDED NEEDLE-BIOPSY THROUGH AERATED VERSUS NONAERATED LUNG [J].
HARAMATI, LB ;
AUSTIN, JHM .
RADIOLOGY, 1991, 181 (03) :778-778
[4]   CT-GUIDED LARGE-BORE BIOPSY - EXTRAPLEURAL INJECTION OF SALINE FOR SAFE TRANSPLEURAL ACCESS TO PULMONARY-LESIONS [J].
KLOSE, KC .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1993, 16 (04) :259-261
[5]   Artificial Pneumothorax With Position Adjustment for Computed Tomography-Guided Percutaneous Core Biopsy of Mediastinum Lesions [J].
Lin, Zheng-Yu ;
Li, Yin-Guan .
ANNALS OF THORACIC SURGERY, 2009, 87 (03) :920-924
[6]   Transthoracic hilar and mediastinal biopsy [J].
Protopapas, Z ;
Westcott, JL .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2000, 38 (02) :281-+
[7]   Protective pneumothorax for needle biopsy of mediastinum and pulmonary hilum [J].
Scalzetti, EM .
JOURNAL OF THORACIC IMAGING, 2005, 20 (03) :214-219
[8]   Protective pneumothorax in CT monitored mediastinal puncture. [J].
Wein, BB ;
Dickgreber, NJ ;
Gunther, RW .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 166 (04) :346-350
[9]  
WEISBROD GL, 1987, CLIN CHEST MED, V8, P27
[10]   MEDIASTINAL TUMORS - BIOPSY UNDER US GUIDANCE [J].
WERNECKE, K ;
VASSALLO, P ;
PETERS, PE ;
VONBASSEWITZ, DB .
RADIOLOGY, 1989, 172 (02) :473-476