Contrast Transcranial Doppler Can Diagnose Large Patent Foramen Ovale

被引:13
作者
Kobayashi, Kazuto [1 ]
Iguchi, Yasuyuki [1 ]
Kimura, Kazumi [1 ]
Okada, Yoko [1 ]
Terasawa, Yuka [1 ]
Matsumoto, Noriko [1 ]
Sakai, Kenichirou [1 ]
Aoki, Jyunya [1 ]
Shibazaki, Kensaku [1 ]
机构
[1] Kawasaki Med Sch, Dept Stroke Med, Kurashiki, Okayama 7010192, Japan
关键词
Right-to-left shunt; Diagnosis; Ultrasound; Transcranial Doppler; Transesophageal echocardiography; TO-LEFT-SHUNTS; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; ISCHEMIC-STROKE; ULTRASOUND; SIZE;
D O I
10.1159/000196820
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Contrast transesophageal echocardiography (c-TEE) and contrast transcranial Doppler (c-TCD) are useful diagnostic tools for detecting right-to-left shunts (RLS). However, the diagnostic accuracy of c-TCD for patent foramen ovale (PFO) remains uncertain. We investigated the relationship between the size of PFO determined by c-TEE and c-TCD findings and assessed the detectable rate of RLS by c-TCD. Methods: We assessed RLS three times using simultaneous c-TCD and c-TEE in 107 patients (321 examinations). We classified all of ultrasound examinations into three groups by size according to microbubbles on c-TEE, such as no PFO (0 microbubble), small PFO (1-29 microbubbles) and large PFO (>= 30 microbubbles). We also calculated the number of microembolic signals (MES) on c-TCD and evaluated the association between PFO size on c-TEE and MES count on c-TCD. Results: In the present study, c-TEE detected RLS in 105 (33%; small PFO, n = 78; large PFO, n = 27), and c-TCD detected RLS in 49 (15%) of 321 examinations. Among 78 examinations with small PFO, MES were found in only 19 (24%) on c-TCD. In contrast, of all 27 examinations with large PFO, MES were found on c-TCD. Also, c-TCD were able to detect MES in 3 of 216 examinations among the no-PFO group. When 6 2 MES on c-TCD was established as the cutoff to predict large PFO on c-TEE, the sensitivity, specificity and accuracy were 96.3, 96.8, and 96.9%, respectively. Conclusion: When two or more MES were determined by c-TCD, large PFO could be accurately diagnosed. Copyright (C) 2009 S. Karger AG, Basel
引用
收藏
页码:230 / 234
页数:5
相关论文
共 18 条
[1]   Almost perfect concordance between simultaneous transcranial Doppler and transesophageal echocardiography in the quantification of right-to-left shunts [J].
Belvís, R ;
Leta, RG ;
Martí-Fàbregas, J ;
Cocho, D ;
Carreras, F ;
Pons-Lladó, G ;
Martí-Vilalta, JL .
JOURNAL OF NEUROIMAGING, 2006, 16 (02) :133-138
[2]   Interobserver and intraobserver variability in detection of patent foramen ovale and atrial septal aneurysm with transesophageal echocardiography [J].
Cabanes, L ;
Coste, J ;
Derumeaux, G ;
Jeanrenaud, X ;
Lamy, C ;
Zuber, M ;
Mas, JL .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (05) :441-446
[3]   Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiography for the detection of patent foramen ovale in stroke patients [J].
Devuyst, G ;
Despland, PA ;
Bogousslavsky, J ;
Jeanrenaud, X .
EUROPEAN NEUROLOGY, 1997, 38 (01) :21-25
[4]   COMPARISON OF DIAGNOSTIC-TECHNIQUES FOR THE DETECTION OF A PATENT FORAMEN OVALE IN STROKE PATIENTS [J].
DITULLIO, M ;
SACCO, RL ;
VENKETASUBRAMANIAN, N ;
SHERMAN, D ;
MOHR, JP ;
HOMMA, S .
STROKE, 1993, 24 (07) :1020-1024
[5]   Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts - Comparison of different procedures and different contrast agents [J].
Droste, DW ;
Kriete, JU ;
Stypmann, J ;
Castrucci, M ;
Wichter, T ;
Tietje, R ;
Weltermann, B ;
Young, P ;
Ringelstein, EB .
STROKE, 1999, 30 (09) :1827-1832
[6]   Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts -: Time window and threshold in microbubble numbers [J].
Droste, DW ;
Silling, K ;
Stypmann, J ;
Grude, M ;
Kemény, V ;
Wichter, T ;
Kühne, K ;
Ringelstein, EB .
STROKE, 2000, 31 (07) :1640-1645
[7]   Right-to-left-shunts detected by transesophageal echocardiography and transcranial Doppler sonography [J].
Droste, DW ;
Schmidt-Rimpler, CS ;
Wichter, T ;
Dittrich, R ;
Ritter, M ;
Stypmann, J ;
Ringelstein, EB .
CEREBROVASCULAR DISEASES, 2004, 17 (2-3) :191-196
[8]   Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts -: Reproducibility, comparison of 2 agents, and distribution of microemboli [J].
Droste, DW ;
Reisener, M ;
Kemény, V ;
Dittrich, R ;
Schulte-Altedorneburg, G ;
Stypmann, J ;
Wichter, T ;
Ringelstein, EB .
STROKE, 1999, 30 (05) :1014-1018
[9]   Ischaemic stroke with malignancy may often be caused by paradoxical embolism [J].
Iguchi, Y. ;
Kimura, K. ;
Kobayashi, K. ;
Ueno, Y. ;
Inoue, T. .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2006, 77 (12) :1336-1339
[10]   Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography [J].
Jauss, M ;
Zanette, E .
CEREBROVASCULAR DISEASES, 2000, 10 (06) :490-496