Optic nerve sheath fenestration for idiopathic intracranial hypertension: A seven year review of visual outcomes in a tertiary centre

被引:20
作者
Obi, Ebube E. [1 ]
Lakhani, Bansri K. [2 ]
Burns, Joyce [1 ]
Sampath, Ragavan [1 ]
机构
[1] Leicester Royal Infirm, Dept Ophthalmol, Leicester LE1 5WW, Leics, England
[2] Leicester Royal Infirm, Dept Med, Leicester LE1 5WW, Leics, England
关键词
Optic nerve sheath fenestration (ONSF); Visual acuity; Visual fields; Idiopathic intracranial hypertension (IIH); Papilloedema; Colour vision; Body mass index; PSEUDOTUMOR CEREBRI; LUMBOPERITONEAL SHUNT; DECOMPRESSION; MEN;
D O I
10.1016/j.clineuro.2015.05.020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose: To determine visual outcomes of patients with Idiopathic intracranial hypertension (IIH), who underwent optic nerve sheath fenestration (ONSF), utilising the two most commonly used tools for monitoring visual function (visual acuity and visual fields) and a third less commonly used tool, colour vision. Methods: A retrospective study of ONSF patients from 2004 to 2011. Patients' symptoms, body mass index, CSF opening pressure, and visual outcomes were analysed. Results: ONSF's were carried out on 31 eyes of 14 patients. 64% were female and 36% were male. The most predominant symptom was a headache (93%). 71% of patients had a BMI > 30. The average CSF opening pressure was 36 mmHg (range 22-64). Post ONSF, visual acuity (VA) improved in 24.1%, remained stable in 62.1% and worsened in 13.8% of operated eyes. 6% were lost to follow up. Visual fields (VF) were reliable in 48% of operated eyes. Of these 33.4% improved, 53.3% remained the same and 13.3% worsened. Colour vision (CV) improved or remained stable in 87%, and worsened in 13% of operated eyes. 4 patients had tertiary procedures (LP or VP shunts). ONSF resulted in statistically significant improvement/stabilisation in visual acuity, visual fields and colour vision. Most importantly, this was not dependent on the body mass index. Conclusion: ONSF is a safe procedure in experienced hands. It predominantly stabilises visual function in majority of maximally medicated patients but also offers improved visual function to some patients. Colour vision monitoring is a useful adjunct in patient with unreliable visual fields. Unfortunately patients whose visual function deteriorated despite maximal medical and surgical treatment were often those who presented late or had a delay in their clinical diagnosis. Crown Copyright (C) 2015 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:94 / 101
页数:8
相关论文
共 36 条
[31]   Is cerebrospinal fluid shunting in idiopathic intracranial hypertension worthwhile? A 10-year review [J].
Sinclair, Alexandra J. ;
Kuruvath, Sarin ;
Sen, Diptasri ;
Nightingale, Peter G. ;
Burdon, Michael A. ;
Flint, Graham .
CEPHALALGIA, 2011, 31 (16) :1627-1633
[32]   Pseudotumor cerebri [J].
Spoor, TC ;
McHenry, JG ;
Shin, DH .
OPHTHALMOLOGY, 1995, 102 (12) :2024-2027
[33]   LONG-TERM EFFECTIVENESS OF OPTIC-NERVE SHEATH DECOMPRESSION FOR PSEUDOTUMOR CEREBRI [J].
SPOOR, TC ;
MCHENRY, JG .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (05) :632-635
[34]   HISTOPATHOLOGICAL AND ULTRASTRUCTURAL EXAMINATION OF OPTIC-NERVE SHEATH DECOMPRESSION [J].
TSAI, JC ;
PETROVICH, MS ;
SADUN, AA .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (02) :182-185
[35]  
Weller B., 1994, Harefuah, V127, P9
[36]   Progressive Optic Neuropathy in Idiopathic Intracranial Hypertension After Optic Nerve Sheath Fenestration [J].
Wilkes, Byron N. ;
Siatkowski, R. Michael .
JOURNAL OF NEURO-OPHTHALMOLOGY, 2009, 29 (04) :281-283