A Noniterative Optimized Algorithm for Shunt Active Power Filter Under Distorted and Unbalanced Supply Voltages

被引:57
作者
Kanjiya, Parag [1 ]
Khadkikar, Vinod [1 ]
Zeineldin, Hatem H. [1 ,2 ]
机构
[1] Masdar Inst Sci & Technol, Abu Dhabi, U Arab Emirates
[2] Cairo Univ, Giza, Egypt
关键词
Active power filter (APF); harmonic compensation; optimized control; power quality; unity power factor (UPF); STRATEGY; COMPENSATION; HARMONICS; DESIGN; SYSTEM; LOADS;
D O I
10.1109/TIE.2012.2235394
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, a single-step noniterative optimized algorithm for a three-phase four-wire shunt active power filter under distorted and unbalanced supply conditions is proposed. The main objective of the proposed algorithm is to optimally determine the conductance factors to maximize the supply-side power factor subject to predefined source current total harmonic distortion (THD) limits and average power balance constraint. Unlike previous methods, the proposed algorithm is simple and fast as it does not incorporate complex iterative optimization techniques (such as Newton-Raphson and sequential quadratic programming), hence making it more effective under dynamic load conditions. Moreover, separate limits on odd and even THDs have been considered. A mathematical expression for determining the optimal conductance factors is derived using the Lagrangian formulation. The effectiveness of the proposed single-step non-iterative optimized algorithm is evaluated through comparison with an iterative optimization-based control algorithm and then validated using a real-time hardware-in-the-loop experimental system. The real-time experimental results demonstrate that the proposed method is capable of providing load compensation under steady-state and dynamic load conditions, thus making it more effective for practical applications.
引用
收藏
页码:5376 / 5390
页数:15
相关论文
共 26 条
[11]   A novel reference compensation current strategy for shunt active power filter control [J].
Chang, GW ;
Shee, TC .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (04) :1751-1758
[12]   A novel approach to the design of a shunt active filter for an unbalanced three-phase four-wire system under nonsinusoidal conditions [J].
Chen, CC ;
Hsu, YY .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (04) :1258-1264
[13]  
Chen M. T., 2003, P IEEE POW ENG SOC T, P422
[14]   POWERS IN NONSINUSOIDAL SITUATIONS - A REVIEW OF DEFINITIONS AND PHYSICAL MEANING [J].
EMANUEL, AE .
IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (03) :1377-1389
[15]   A DSP based optimal algorithm for shunt active filter under nonsinusoidal supply and unbalanced load conditions [J].
George, Sincy ;
Agarwal, Vivek .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (02) :593-601
[16]  
GRADY WM, 2001, IEEE POWER ENG REV, V21, P8, DOI DOI 10.1109/MPER.2001.961997
[17]   A control algorithm for three-phase three-wired active power filters under nonideal mains voltages [J].
Huang, SJ ;
Wu, JC .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1999, 14 (04) :753-760
[18]   A control algorithm for compensation of customer-generated harmonics and reactive power [J].
Jain, SK ;
Agarwal, P ;
Gupta, HO .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) :357-366
[19]   Comparison of control strategies for shunt active power filters in three-phase four-wire systems [J].
Milanes Montero, Maria Isabel ;
Romero Cadaval, Enrique ;
Barrero Gonzalez, Fermin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (01) :229-236
[20]   Reference current estimation under distorted line voltage for control of shunt active power filters [J].
Moreno, VM ;
López, AP ;
Garcías, RID .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (04) :988-994