In this paper, a single-step noniterative optimized algorithm for a three-phase four-wire shunt active power filter under distorted and unbalanced supply conditions is proposed. The main objective of the proposed algorithm is to optimally determine the conductance factors to maximize the supply-side power factor subject to predefined source current total harmonic distortion (THD) limits and average power balance constraint. Unlike previous methods, the proposed algorithm is simple and fast as it does not incorporate complex iterative optimization techniques (such as Newton-Raphson and sequential quadratic programming), hence making it more effective under dynamic load conditions. Moreover, separate limits on odd and even THDs have been considered. A mathematical expression for determining the optimal conductance factors is derived using the Lagrangian formulation. The effectiveness of the proposed single-step non-iterative optimized algorithm is evaluated through comparison with an iterative optimization-based control algorithm and then validated using a real-time hardware-in-the-loop experimental system. The real-time experimental results demonstrate that the proposed method is capable of providing load compensation under steady-state and dynamic load conditions, thus making it more effective for practical applications.
引用
收藏
页码:5376 / 5390
页数:15
相关论文
共 50 条
  • [1] An Optimization-Based Algorithm for Shunt Active Filter Under Distorted Supply Voltages
    Uyyuru, Koteswara Rao
    Mishra, Mahesh K.
    Ghosh, Arindam
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (5-6) : 1223 - 1232
  • [2] Constant Instantaneous Power Based Controller for a Shunt Active Power Filter under Balanced, Unbalanced, and Distorted Supply Conditions
    Khalid, Saifullah
    Dwivedi, Bharti
    Mishra, V. M.
    2015 INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATION & AUTOMATION (ICCCA), 2015, : 963 - 967
  • [3] An optimization based algorithm for shunt active filter under unbalanced and nonsinusoidal supply voltages
    Koteswara, Rao U.
    Mishra, Mahesh K.
    Vincent, G.
    ICIEA 2008: 3RD IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, PROCEEDINGS, VOLS 1-3, 2008, : 1475 - 1480
  • [4] Predictive Tuned Filter based Reference Current Generation for Shunt Active Power Filter under Distorted and Unbalanced Supply Voltage
    Gali, Vijayakumar
    Gupta, Nitin
    Gupta, R. A.
    2018 NATIONAL POWER ENGINEERING CONFERENCE (NPEC), 2018,
  • [5] Direct power control of shunt active filter using high selectivity filter (HSF) under distorted or unbalanced conditions
    Mesbahi, Nadhir
    Ouari, Ahmed
    Abdeslam, Djaffar Ould
    Djamah, Tounsia
    Omeiri, Amar
    ELECTRIC POWER SYSTEMS RESEARCH, 2014, 108 : 113 - 123
  • [6] Third order sinusoidal integrator (TOSSI)-based control algorithm for shunt active power filter under distorted and unbalanced voltage conditions
    Chilipi, Rajasekharareddy
    Al Sayari, Naji
    Al Hosani, Khalifa
    Fasil, Muhammed
    Beig, Abul R.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 96 : 152 - 162
  • [7] Comparison of Active Power Filter Reference Current Detection Methods under Distorted and Unbalanced PCC Voltages
    Popa, D. L.
    Nicolae, P. M.
    2014 INTERNATIONAL CONFERENCE ON APPLIED AND THEORETICAL ELECTRICITY (ICATE), 2014,
  • [8] Achieving Maximum Possible Power Factor with Single-Phase Shunt Active Power Filter under Distorted Supply Condition
    Kanjiya, Parag
    Khadkikar, Vinod
    Zeineldin, H. H.
    2012 IEEE FIFTH POWER INDIA CONFERENCE, 2012,
  • [9] A Novel Technique For Implementation of Shunt Active Power Filter Under Balanced And Unbalanced Load Conditions
    Karvekar, Sushil
    Patil, Dadgonda
    PROCEEDINGS OF 2013 INTERNATIONAL CONFERENCE ON CIRCUITS, POWER AND COMPUTING TECHNOLOGIES (ICCPCT 2013), 2013, : 1 - 5
  • [10] A DSP based optimal algorithm for shunt active filter under nonsinusoidal supply and unbalanced load conditions
    George, Sincy
    Agarwal, Vivek
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (02) : 593 - 601