Determination of haloperidol drug in ampoules and in urine samples using a potentiometric modified carbon paste electrode

被引:30
作者
Abu Shawish, Hazem M. [1 ]
Almonem, Khaled I. Abed [2 ]
Saadeh, Salman M. [3 ]
Al-Iham, Wael S. [4 ]
机构
[1] Al Aqsa Univ, Coll Sci, Dept Chem, Gaza, Israel
[2] Minesty Educ & Higher Educ, Gaza, Israel
[3] Islamic Univ, Coll Sci, Dept Chem, Gaza, Israel
[4] Forens Lab, Gaza, Israel
关键词
Potentiometry; Haloperidol drug; Carbon paste electrode; Ion-selective electrode; ION-SELECTIVE ELECTRODES; MEMBRANE;
D O I
10.1016/j.measurement.2015.10.008
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A modified carbon paste electrode for haloperidol drug based on haloperidolphosphomolybdate (HP-PM) as an ion-exchanger dissolved in plasticizer DBP and its potentiometric characteristics were discussed. The electrode exhibited a good Nernstian slope of 56.9 +/- 0.3 mV/decade with a linear concentration range from 3.2 x 10(-6) to 1.0 x 10(-2) M for the haloperidol ion. The limit of detection (LOD) was 1.5 x 10(-6) M. It had response time of 5-8 seconds (s), useable in pH range of 6.2-8.6 and temperature of 20-60 degrees C. The electrode shows clear discrimination of haloperidol drug from several inorganic ions, sugars and some common drug excipients. The sensor was applied for determination of haloperidol drug in urine and in pharmaceutical formulations using potentiometric determination, standard addition and the calibration curve methods. The results are satisfactory with excellent percentage recovery comparable or better than those obtained by other routine methods. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:180 / 186
页数:7
相关论文
共 33 条
[1]   A new potentiometric sensor for the determination of ketamine hydrochloride in ampoules and urine [J].
Abu Shawish, Hazem M. ;
Saadeh, Salman M. ;
Tamos, Hassan ;
Abed-Almonem, Khalid I. ;
Al Khalili, Osama .
ANALYTICAL METHODS, 2015, 7 (01) :301-308
[2]   A comparative study of solid and liquid inner contact benzalkonium chloride ion-selective electrode membranes [J].
Abu Shawish, Hazem M. ;
Khedr, Abdalla M. ;
Abed-Almonem, Khalid I. ;
Gaber, M. .
TALANTA, 2012, 101 :211-219
[3]   Modified carbon paste electrode for potentiometric dibromide pesticide in water and urine samples [J].
Abu Shawish, Hazem M. ;
Abu Ghalwa, Nasser ;
Hamada, Mazen ;
Basheer, Abdel-Hakem .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (02) :140-145
[4]  
Abu-Shawish HM, 2007, CAN J ANAL SCI SPECT, V52, P225
[5]   Potentiometric response of modified carbon paste electrode based on mixed ion-exchangers [J].
Abu-Shawish, Hazem M. .
ELECTROANALYSIS, 2008, 20 (05) :491-497
[6]   A mercury(II) selective sensor based on N,N′-bis(salicylaldehyde)-phenylenediamine as neutral carrier for potentiometric analysis in water samples [J].
Abu-Shawish, Hazem M. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 167 (1-3) :602-608
[7]   Liquid chromatographic-mass spectrometric determination of haloperidol and its metabolites in human plasma and urine [J].
Arinobu, T ;
Hattori, H ;
Iwai, M ;
Ishii, A ;
Kumazawa, T ;
Suzuki, O ;
Seno, H .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 776 (01) :107-113
[8]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[9]   COATED WIRE ION SELECTIVE ELECTRODES [J].
CATTRALL, RW ;
FREISER, H .
ANALYTICAL CHEMISTRY, 1971, 43 (13) :1905-&
[10]   Separation and determination of haloperidol, parabens and some of their degradation products by micellar electrokinetic chromatography [J].
Driouich, R ;
Takayanagi, T ;
Oshima, M ;
Motomizu, S .
JOURNAL OF CHROMATOGRAPHY A, 2000, 903 (1-2) :271-278