Although heat pump water heaters are today widely accepted in Japan, where energy costs are high and government incentives for their use exist, acceptance of such a product in the U.S. has been slow. This trend is slowly changing with the introduction of heat pump water heaters into the residential market, but remains in the commercial sector. Barriers to heat pump water heater acceptance in the commercial market have historically been performance, reliability and first/operating costs. The use of carbon dioxide (R744) as the refrigerant in such a system can improve performance for relatively small increase in initial cost and make this technology more appealing. What makes R744 an excellent candidate for use in heat pump water heaters is not only the wide range of ambient temperatures within which it can operate, but also the excellent ability to match water to refrigerant temperatures on the high side, resulting in very high exit water temperatures of up to 82 degrees C (180 degrees F), as required by sanitary codes in the U.S.(Food Code, 2005), in a single pass, temperatures that are much more difficult to reach with other refrigerants. This can be especially attractive in applications where this water is used for the purpose of sanitation. While reliability has also been of concern historically, dramatic improvements have been made over the last several years through research done in the automotive industry and commercialization of R744 technology in residential water heating mainly in Japan. This paper presents the performance results from the development of an R744 commercial heat pump water heater of approximately 35kW and a comparison to a baseline R134a unit of the same capacity and footprint. In addition, recommendations are made for further improvements of the R744 system which could result in possible energy savings of up to 20%.
引用
收藏
页码:544 / +
页数:2
相关论文
共 50 条
  • [21] Review of energy efficiency and system performance of residential heat pump water heaters
    Willem, H.
    Lin, Y.
    Lekov, A.
    ENERGY AND BUILDINGS, 2017, 143 : 191 - 201
  • [22] Performance and improvements in heat pump dryers
    Alves, O
    Strommen, I
    DRYING '96, VOL A, 1996, : 405 - 416
  • [23] CO2 heat pump water heaters
    Zogg, Robert
    Roth, Kurt
    Radermacher, Reinhard
    Brodrick, James
    ASHRAE JOURNAL, 2007, 49 (11) : 52 - 54
  • [24] A statistical methodology to compare the performance of residential air source heat pump water heaters
    Tangwe, Stephen
    Kusakana, Kanzumba
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2021, 40 (08) : 719 - 738
  • [25] A drying heat pump using carbon dioxide as working fluid
    Klöcker, K
    Schmidt, EL
    Steimle, F
    DRYING TECHNOLOGY, 2002, 20 (08) : 1659 - 1671
  • [26] Parametric study on the performance of a direct-expansion geothermal heat pump using carbon dioxide
    Austin, Brian T.
    Sumathy, K.
    APPLIED THERMAL ENGINEERING, 2011, 31 (17-18) : 3774 - 3782
  • [27] PERFORMANCE ANALYSIS OF A CARBON DIOXIDE HEAT PUMP INSTALLED IN A RESIDENTIAL APPLICATION
    Arteconi, A.
    Ciarrocchi, E.
    Polonara, F.
    Chen, J. F.
    Deng, S.
    Wang, R. Z.
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 520 - 526
  • [28] Peak Reduction using Mode Adjustment of Heat Pump Water Heaters in a Residential Neighborhood
    Tsybina, Eve
    Winstead, Chris
    Hill, Justin
    Amasyali, Kadir
    Agah, Nora
    Lebakula, Viswadeep
    Munk, Jeff
    Zandi, Helia
    2023 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES LATIN AMERICA, ISGT-LA, 2023, : 455 - 459
  • [29] Simulation of packaged solar heat-pump water heaters
    Morrison, G.L.
    Solar energy, 1994, 53 (03): : 249 - 257
  • [30] Refrigerant charge optimisation for propane heat pump water heaters
    Ghoubali, Redouane
    Byrne, Paul
    Bazantay, Frederic
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 76 : 230 - 244