AN ANALYSIS OF ENERGY, EXERGY, AND SUSTAINABLE DEVELOPMENT OF A VAPOR COMPRESSION REFRIGERATION SYSTEM USING HYDROCARBON

被引:22
作者
Ahamed, J. U. [1 ]
Saidur, R. [1 ]
Masjuki, H. H. [1 ]
Sattar, M. A. [1 ]
机构
[1] Univ Malaya, Dept Mech Engn, Kuala Lumpur 50603, Malaysia
关键词
Coefficient of performance; Hydrocarbon refrigerants; Exergy loss; Exergy efficiency; Sustainability index; DOMESTIC REFRIGERATORS; ENVIRONMENTAL-IMPACT; POWER-GENERATION; 2ND LAW; MIXTURE; HEAT; EFFICIENCY; OPTIMIZATION; SUBSTITUTES; CFCS;
D O I
10.1080/15435075.2011.621491
中图分类号
O414.1 [热力学];
学科分类号
摘要
Hydrocarbons being natural fluid have drawn much attention of the scientists and researchers for the application as a sustainable material for the vapor compression refrigeration system. This paper presents a comparison of the energetic and exergetic performances of a domestic refrigerator using pure butane and isobutane as refrigerants. The thermodynamic performances such as exergy destruction or losses, exergy efficiency, and coefficient of performances (COP) were investigated. These parameters were measured at varied operating conditions. Exergy and energy efficiencies of isobutane were found to be 50% and 175% higher than that of R-134a. The analysis shows that the performances of butane and isobutane as refrigerants are comparable with HFC134a. It has also been found that at higher evaporating temperatures, the exergy losses are minimal. The maximum exergy loss occurred in the compressor and the value was 69% of the whole losses in the system. Highest sustainability index was found for butane compared to that of R134a and R600a, respectively.
引用
收藏
页码:702 / 717
页数:16
相关论文
共 42 条
[31]   Thermodynamic analysis of wind energy [J].
Sahin, Ahmet Duran ;
Dincer, Ibrahim ;
Rosen, Marc A. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2006, 30 (08) :553-566
[32]  
Sattar M.A., 2008, THESIS U MALAYA MALA
[33]   HFC134a/HC600a/HC290 mixture a retrofit for CFC12 systems [J].
Sekhar, SJ ;
Lal, DM .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (05) :735-743
[35]   INTERNATIONAL PROGRESS IN 2ND LAW ANALYSIS [J].
SZARGUT, J .
ENERGY, 1980, 5 (8-9) :709-718
[36]  
Szargut J., 1988, EXERGY ANAL THERMAL
[37]   Experimental study of new refrigerant mixtures to replace R12 in domestic refrigerators [J].
Tashtoush, B ;
Tahat, M ;
Shudeifat, MA .
APPLIED THERMAL ENGINEERING, 2002, 22 (05) :495-506
[38]  
United Nations Development Programme, 1999, STUD POT HYDR REPL E
[39]  
Vincent C.E., 2006, DOM US EN C CALV COL
[40]   Experimental investigation of hydrocarbon mixtures to replace HFC-134a in an automotive air conditioning system [J].
Wongwises, S ;
Kamboon, A ;
Orachon, B .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (11-12) :1644-1659